Simplici-T® Annuloplasty System

Medtronic Epicardial Lead Implant ToolRepair Redefined

The Simplici-T® Annuloplasty System offers a first-of-its-kind approach to mitral and tricuspid valve repair. The Simplici-T® System is the first flexible band to eliminate the need for traditional sizing, providing a custom fit for every patient and requiring less inventory space.

  • No more sizing: The Simplici-T® System is based on the “no sizing” implant technique of Dr. Tirone David, one of the world’s most outstanding technical cardiac surgeons.
  • Customized for every patient: The flexible band and holder adapts to the unique needs of every patient. Implanted band length is determined by the annular size and degree of plication of the annular tissue.
  • Reduces inventory: The flexible annuloplasty band is supplied in a length of 100mm and requires no additional accessories.
  • Offers the benefits of a flexible band, including:
    • Better early postoperative LV systolic function over patients with a rigid ring1
    • Allows annulus size and configuration to adapt to changes throughout cardiac cycle2-4
    • Better diastolic blood flow a cross the mitral valve, particularly during exercise5
    • Flexible annuloplasty repair devices place less stress on the sutures during systole, minimizing the likelihood of dehiscence6

“I have not sized a mitral valve for an annuloplasty band for more than a decade. Simplici-T® allows the surgeon to tailor the length of the band according to the pathology.”
Tirone E. David, M.D.*

> Download Product Brochure

For more information, call 800-328-2518 or select one of the topics below.


REFERENCES

1. David TE, Armstrong S, Sun Z. Left ventricular function after mitral valve surgery. J Heart Dis. 1995;4:S175-80.

2. Tsakiris AG, Von Vernuth G, Rastilli GC, et al. Size and motion of the mitral valve in anesthetized Intact dogs. J Appl Phys. 1971;30:611

3. Ormiston JA, Shah PM, Tei C, et al. Size and motion in the mitral valve annulus in man. Circulation. 1981;64:113.

4. Duran CMG, Ubago JLM. Clinical and hemodynamic performance of a totally flexible prosthetic ring for atrio-ventricular valve reconstruction. Ann Thorac Surg. 1976;22:458-63.

5. Okada Y, Shomura T, Yamaura YI, et al. Comparison of the Carpentier and Duran prosthetic rings used in mitral reconstruction. Ann Thorac Surg. 1995;59:658-63.

6. Duran C. Perspectives for acquired valvular disease. In: Advanced Cardiac Surgery, Vol. 4, 1993.

* Tirone E. David receives royalties from Medtronic, Inc. on sales of the Simplici-T annuloplasty system.

Glossary Contact Medtronic Privacy Statement Terms of Use
Home About Medtronic