PATIENT SELECTION: OCD DEEP BRAIN STIMULATION

CANDIDATES FOR DBS THERAPY

Best results are achieved when the patient and caregiver are fully informed about the therapy risks and probable benefits, surgical procedures, follow-up requirements, and self-care responsibilities.

Reclaim™ DBS Therapy for OCD* may be considered for patients who meet the following criteria:

  • Have a diagnosis of OCD with a documented duration of at least 5 years
  • Have OCD rated as severe or chronic extreme illness
  • Have a Yale-Brown Obsessive Compulsive Scale (YBOCS) score of greater than or equal to 30
  • Have comorbid depression and anxiety
  • Have failed to improve following treatment with at least three selective serotonin reuptake inhibitors (SSRIs) with augmentation
  • Do not have hoarding as their primary subclassification
  • Have completed or tried to complete Cognitive Behavior Therapy (CBT)
  • Have no serious psychiatric disorder in addition to OCD (e.g. comorbid personality disorder) or substance abuse issues
  • Meet established criteria for implantation of a deep brain stimulation system
  • Are 18 years old or older
  • Have not had a previous surgery to destroy the region of the brain that will be the target of stimulation
  • Are not pregnant
  • Have no other neurological disorders, including dementia
  • Do not have a bleeding disorder or are not taking blood thinners

Use extreme care with lead implantation in patients with a heightened risk of intracranial hemorrhage. Physicians should consider underlying factors, such as previous neurological injury or prescribed medications (anticoagulants), that may predispose a patient to the risk of bleeding.

Physicians should be aware that the risks associated with initial surgery may increase with clinical conditions such as:

  • Stroke or neurological disorders
  • Cardiovascular disease
  • Renal or hepatic failure
  • Diabetes mellitus

To help ensure maximum benefits from the neurostimulation system, long-term, post-surgical management of patients is recommended.

Stimulation parameters should be adjusted such that maximal symptom improvement is achieved with minimal side effects. High parameter values may indicate a system problem or less than optimal lead placement. Patients should be informed of the risks of higher stimulation parameters, which may result in possible excessive charge density. Refer to the Information for Prescribers Addendum for OCD for more information about excessive charge density.