Medtronic Open Pivot Aortic Valved Graft (AVG) for Aortic Valve and Ascending Aorta Replacement

The Medtronic Open Pivot aortic valved graft unites a fundamentally different bileaflet heart valve design with leading graft technology for exceptional implantability.

View Product Details

Overview

Bileaflet Valve

Product Details

Excellent Hemodynamics

In-vivo studies demonstrate excellent hemodynamics.3-5

Easy Implantability

With no tapers or pleats, the Medtronic Open Pivot AVG allows for easy anastomosis anywhere on the graft. A larger graft internal diameter minimizes stress on coronary anastomosis, and the rotatable valve allows for optimal leaflet positioning.

Proven Graft Material

The Hemashield®* Woven Double Velour graft is made with a low-porosity graft material to improve hemostasis.6,7 Excellent resorption rates facilitate healing.6 The graft material also offers exceptional handling characteristics.

Simple Valve Selection 

Convenient accessories include nine white-handled, single-ended standard heart valve sizers. Each sizer handle has a clear cylindrical ring that approximates the patient’s tissue annulus size for appropriate valve selection.

Additional Resources

Contact Information

LifeLine CardioVascular
Technical Support

877-526-7890

Send Us an Email

Medtronic
Mitral Academy

Training, education, and collaboration on the treatment of mitral and tricuspid valve disease.

Register Here
*

Hemashield® is a registered trademark of MAQUET Cardiovascular, LLC.

References

1

Kelly SG, Verdonck PR, Vierendeels JA, Riemslagh K, Dick E, Van Nooten GG. A three-dimensional analysis of flow in the pivot regions of an ATS bileaflet valve. Int J Artif Organs. November 1999;22(11):754-763.

2

Emery RW, Petersen RJ, Kersten TE, et al. The initial United States experience with the ATS mechanical cardiac valve prosthesis. Heart Surg Forum. 2001;4(4):346-352.

3

Emery RW, Krogh CC, Jones DJ, Nicoloff DM, Blake DP, Arom KV. Five-year follow up of the ATS mechanical heart valve. J Heart Valve Dis. March 2004;13(2):231-238.

4

Westaby S, Van Nooten G, Sharif H, Pillai R, Caes F. Valve replacement with the ATS open pivot bileaflet prosthesis. Eur J Cardiothorac Surg. 1996;10(8):660-665.

5

Premarket Approval (PMA). U.S. Food & Drug Administration. Available at: www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P990046. Accessed April 20, 2021.

6

Westaby S, Parry A, Giannopoulos N, Pillai R. Replacement of the thoracic aorta with collagen-impregnated woven Dacron grafts. Early results. J Thorac Cardiovasc Surg. September 1993;106(3):427-433.

7

Hirt SW, Aoki M, Demertzis S, Siclari F, Haverich A, Borst HG. Comparative in vivo study on the healing qualities of four different presealed vascular prostheses. J Vasc Surg. March 1993;17(3):538-545.