Overview

A full array of etCO2 sampling lines that fit every patient and meet every capnography clinical need.

The patented family of FilterLine® etCO2 sampling lines is designed for use with Microstream™-enabled capnography monitors and can be used on both intubated and non-intubated patients.

FilterLine® non-intubated sampling lines feature oral and nasal sampling as well as an innovative supplemental oxygen delivery system. One size fits adolescents through adults, and all FilterLine® non-intubated sampling lines can be used with bi-level ventilation and CPAP. For some types of non-intubated sampling lines, paediatric products are also available.

Microstream™ Advance EtCO₂ Capnography Sampling Lines Technology

Discover the advantages of the Microstream™ Capnography Sampling Lines in this video.

Product Features

  • New PVC tubing material with reduced smell and soft tubing designed to lay gently on the patient face
  • New design of the non-intubated long-term lines, with drying element away from the patient face
  • New Okink-resistant tubing engineered to help mitigate interrupted oxygen flow and resulting alarms
  • New product packaging, with easy-tear opening and labeling to improve experience and ease of use, with Medtronic branding
  • Labeling according to EU MDR requirements and change in EC
  • New product naming structure and order codes updated to be more intuitive for easily identifying the right one
  • 0.2 micron sterilizing-grade filter designed to prevent liquids from entering the monitor, reducing the risk of biohazard contamination of the monitor1
  • Intubated and non-intubated design, available in neonate, paediatric, and adult sizes
  • Uni-junction™ technology designed for effective sampling from both nares and the mouth, even at low tidal volumes
  • Nasal prongs providing dual nare sampling, and oral scoop capturing CO2 samples from mouth breathers
  • Oxygen delivered in a cloud from pinholes around the mouth and nose — helping to ensure delivery without diluting measurements or waveforms

How to Order

For additional information or to place an order, call Customer Service at +44 (0) 19 2320 2504.

Order Information
Legacy sku new sku Description Unit of Measure Quantity
Non-intubated patients, long term use
010433 MVAOH Advance FilterLine® oral/nasal, adult w/O2 tubing Box 25
010625 MVAOH100U Advance FilterLine® oral/nasal, adult w/O2 tubing, 100ct Box 100
012463 MVAOHL Advance FilterLine® oral/nasal, adult w/O2 tubing, long Box 25
010582 MVPOH Advance FilterLine® oral/nasal, pediatric w/O2 tubing Box 25
012464 MVPOHL Advance FilterLine® oral/nasal, pediatric w/O2 tubing, long Box 25
008177 MVANH Advance FilterLine® nasal, adult Box 25
008179 MVINH Advance FilterLine® nasal, neonatal-infant Box 25
012465 MVINHL Advance FilterLine® nasal, neonatal-infant, long Box 25
008180 MVANOH Advance FilterLine® nasal, adult w/O2 tubing Box 25
008181 MVPNOH Advance FilterLine® nasal, pediatric w/O2 tubing Box 25
012111 MVINOH Advance FilterLine® nasal, neonatal-infant w/O2 tubing, 3m Box 25
Non-intubated patients, short term use
009818 MVA Advance FilterLine® oral/nasal, adult Box 25
010209 MVA100U Advance FilterLine® oral/nasal, adult, 100ct Box 100
010340 MVAL Advance FilterLine® oral/nasal, adult, long Box 25
010339 MVAL100U Advance FilterLine® oral/nasal, adult, long, 100 ct Box 100
009822 MVAO Advance FilterLine® oral/nasal, adult, w/O2 tubing Box 25
010210 MVAO100U Advance FilterLine® oral/nasal, adult w/O2 tubing, 100 ct Box 100
009826 MVAOL Advance FilterLine® oral/nasal, adult w/O2 tubing, long Box 25
010341 MVAOL100U Advance FilterLine® oral/nasal, adult w/O2 tubing, long, 100 ct Box 100
007266 MVP Advance FilterLine® oral/nasal, pediatric Box 25
007269 MVPO Advance FilterLine® oral/nasal, pediatric w/O2 tubing Box 25
007743 MVPOL Advance FilterLine® oral/nasal, pediatric w/O2 tubing, long Box 25
012528 MVAB Advance FilterLine® adult-intermediate with bite block and w/O2 tubing- male connector Box 25
012537 MVAB100U Advance FilterLine® adult-intermediate with bite block and w/O2 tubing- male connector, 100 ct Box 100
012529 MVABO Advance FilterLine® adult-intermediate with bite block and w/O2 tubing- female connector Box 25
012538 MVABO100U Advance FilterLine® adult-intermediate with bite block and w/O2 tubing- female connector, 100 ct Box 100
012530 MVABOL Advance FilterLine® adult-intermediate w/O2 tubing- female connector, long Box 25
012539 MVABOL100U Advance FilterLine® adult-intermediate with bite block and w/O2 tubing- female connector, long, 100 ct Box 100
006912 MVANO Advance FilterLine® nasal, adult w/O2 tubing Box 25
010304 MVANO100U Advance FilterLine® nasal, adult w/O2 tubing, 100 ct Box 100
007739 MVANOL Advance FilterLine® nasal, adult w/O2 tubing, long Box 25
010344 MVANOL100U Advance FilterLine® nasal, adult w/O2 tubing, long, 100 ct Box 100
006913 MVPNO Advance FilterLine® nasal, pediatric w/O2 tubing Box 25
XS04476 MVIN Advance FilterLine® nasal NIV line, neonatal Box 25
008174 MVAN Advance FilterLine® nasal NIV line, adult Box 25
008175 MVPN Advance FilterLine® nasal NIV line, pediatric Box 25
Intubated patients, long term use
XS04624 MVAIH Advance FilterLine® Intubated, adult-pediatric Box 25
010580 MVAIH100U Advance FilterLine® Intubated, adult-pediatric, 100 ct Box 25
007737 MVAIHL Advance FilterLine® Intubated, adult-pediatric, long Box 100
006324 MVIIH Advance FilterLine® Intubated, neonatal-infant Box 25
007738 MVIIHL Advance FilterLine® Intubated, neonatal-infant, long Box 25
010787 MVAIHH Advance FilterLine® Intubated, adult-pediatric, high humidity Box 25
010807 MVIIHH Advance FilterLine® Intubated, neonatal-infant, high humidity Box 25
Intubated patients, short term use
XS04620 MVAI Advance FilterLine® Intubated, adult-pediatric Box 25
010579 MVAI100U Advance FilterLine® Intubated, adult-pediatric, 100 ct Box 100
007768 MVAIL Advance FilterLine® Intubated, adult-pediatric, long Box 25
Specifications
  • Standard FilterLine® Length: 200 cm /6.5 ft.
  • Long FilterLine® Length: Long FilterLine Length: 400 cm/13 ft.
  • Designed for single patient use.
  • Do not contain natural rubber latex.
  • Packaged in 25 units unless otherwise specified.
  • Adult/Paediatric products are intended for use with ETT tube size > 4.5 mm.
  • The adapter dead space is < 6.6 cc and the weight is 7.0 g.
  • Infant/neonate products are intended for use with ETT tube size ≤ 4.5 mm.
  • The adapter dead space is < 0.5 cc and the weight is 3.8 g.
  • Use of a FilterLine® etCO2 sampling line with H in its name (indicating that it is for use in humidified environments) during MRI scanning may cause interference. The use of non-H sampling lines is advised.

Order Information

Connect with Medtronic Patient Monitoring & Respiratory Interventions
Your platform for clinical & product educational content. 

  • 1. Microbial Challenge of the FilterLine, AppTec, of Marietta GA, Protocol Number ORI032505CMC.01, July 7, 2005.