Overview

Helping to Prevent Cross-Contamination to Caregivers and Other Patients

A disposable filter designed to reduce particles and bacteria in the patient’s exhaled gas, and protect the ventilator’s systems as well as others in the room breathing the same air.

The Puritan Bennett™ pediatric-adult disposable expiratory filtration system reduces particles, virus and bacteria in the patient’s exhaled gas while using the Puritan Bennett™ 980 ventilator, protecting the ventilator’s exhalation and spirometry systems and other people in the room from airborne pathogens.

Product Features

  • Latex-free
  • Single patient use design enables one filter to cover up to 15 days of a single patient’s stay
  • Comprehensive condensate drainage system includes one-piece filter and collector vial and optional drain bag
  • Optional drain bag allows for condensation removal without breaking the ventilator circuit
  • Viral and bacterial filtration efficiency of greater than 99.999%
  • Resistance to flow less than 0.7 cmH2O at 30 L/min and 0.35 cmH2O at 15 L/min when new
  • Minimum of 99.97% filtration efficiency of 0.3 microns nominal particle size at 30 L/min flow
  • Meets CDC requirement for N100 filtration equivalency

How to Order

For additional information or to place an order, call Customer Service at +44 (0) 19 2320 2504.

Order Information
Order Code Description Unit of Measure Quantity
10043551 Puritan Bennett™ Pediatric-Adult Expiratory Filtration System, Disposable Case 12
4-048491-00 Puritan Bennett™ Drain Bag, Single Patient Use Case 25
4-048492-00 Puritan Bennett™ Drain Bag Clamp, Reusable Case 5
4-048493-00 Puritan Bennett™ Drain Bag Tubing, Single Patient Use Case 10
4-074613-00 Puritan Bennett™ Drain Port Cap, Reusable Box 1
Specifications
Latex-free
Recommended tidal volume and flow range Refer to the Puritan Bennett™ 980 Series Ventilator Operator’s Manual
Inlet connector 22 mm male conical connector (ISO 5356-1)
Viral and bacterial filtration efficiency Greater than 99.999%
Penetration value Maximum of 0.03% penetration of 0.3 μm nominal particle size at 30 L/min flow
Gas leakage Less than 10 mL per minute at 100 hPa (100 cm H2O)
Pressure drop (when new) Less than 0.7 hPa (0.7 cm H2O) at 30 L/min
  0.35 hPa (0.35 cm H2O) at 15 L/min
Size (with condensate vial) 8.9 cm diameter x 17.8 cm long (3.5 in. diameter x 7 in. long)
Internal gas volume (with condensate vial) Approximately 600 mL
Condensate vial liquid capacity Approximately 200 mL usable volume (to maximum fill line)
Condensate vial drain port size 6.5 mm (.25 in.) I.D. tube

Order Information

Connect with Medtronic Patient Monitoring & Respiratory Interventions
Your platform for clinical & product educational content.