Cool-tip™ RF Ablation Single Electrode Kits E Series

Long Description:

Each single electrode kit includes one single 17-gauge electrode, one grounding pad and an inflow and outflow tubing set.

[Read More]

Specifications

Specifications:

Order Information

Order Code Length Exposure Ordering Quantity
RFA1020 10 cm 2 cm 1 Each
RFA1030 10 cm 3 cm 1 Each
RFA1507 14.4 cm 0.7 cm 1 Each
RFA1510 15 cm 1 cm 1 Each
RFA1520 15 cm 2 cm 1 Each
RFA1530 15 cm 3 cm 1 Each
RFA2020 20 cm 2 cm 1 Each
RFA2030 20 cm 3 cm 1 Each
RFA2530 25 cm 3 cm 1 Each

[Read Less]

Cool-tip™ RF Ablation Cluster Electrode Kits E Series

Long Description:

Each cluster electrode kit includes one cluster 17-gauge electrode, one cluster introducer, two grounding pads and an inflow and outflow tubing set.

[Read More]

Specifications

Specifications:

Order Information

Order Code Length Exposure Ordering Quantity
RFAC1025 10 cm 2.5 cm 1 Each
RFAC1525 15 cm 2.5 cm 1 Each
RFAC2025 10 cm 2.5 cm 1 Each

[Read Less]

Cool-tip™ RF Ablation Multiple Electrode Kits E Series

Long Description:

Multiple electrode kits include sets of two or three single 17-gauge electrodes, one spacer, two grounding pads and an inflow and outflow tubing set.

 

[Read More]

Specifications

Specifications:

Order Information

Order Code Length Exposure Number of Electrodes Ordering Quantity
RFA15302 15 cm 3 cm 2 1 Each
RFA15303 15 cm 3 cm 3 1 Each
RFA15403 15 cm 4 cm 3 1 Each
RFA25303 25 cm 3 cm 3 1 Each
RFA25403 25 cm 4 cm 3 1 Each

[Read Less]

Cool-tip™ RF Ablation Remote Temperature Probes E Series

Long Description:

Optional remote temperature probes allow real-time tissue temperature monitoring for extra assurance.

  • Measures tissue temperature in or adjacent to ablation zone
  • If desired, automatically stops RF delivery based on temperature

 

[Read More]

Specifications

Specifications:

Order Information

Order Code Length Ordering Quantity
RTP20 20 cm 1 Each
RTP20B 20 cm 5 Units/Box

[Read Less]

RF Ablation High-Power Patient Return Electrode E Series

Long Description:

Innovative patient return electrode helps in protecting against potential for hotspots and reduces number of pads required.

  • Split electrode technology provides independent current monitoring of each half of the pad
  • Breathable backing dissipates heat

 

[Read More]

Specifications

Specifications:

Order Information

Order Code Ordering Quantity
RFAPADB 20 Units/Box

[Read Less]
Overview:

Designed for Versatility, Flexibility and Patient Safety

Cool-tip™ RF ablation system E Series* electrodes are preferred worldwide for their 17-gauge straight needle design with trocar-style tips allowing them to be inserted and positioned like biopsy needles. The internally-cooled design limits tissue charring and permits increased energy deposition for potentially larger ablation volumes.

Intuitive patient return electrodes help protect against potential for hotspots and reduce the number of pads required.

An optional remote temperature probe allows real-time tissue monitoring for extra assurance of patient safety.


*The Cool-tip™ RF ablation system E Series is not available for sale in the United States. All Cool-tip™ products bear the CE Mark.