Fully Integrated CRT Implant System
 
201005845cvrintro

Attain Integrated CRT Implant System

Placing the left-heart lead can be the most difficult part of the cardiac resynchronization therapy implant procedure. With Medtronic advanced leads and delivery systems, you have many options to navigate difficult anatomy to improve the chances of a successful implant, so that more of your patients can enjoy the advantages of cardiac resynchronization therapy (CRT).

Portfolio Summary

system-in-veinsth

Detail
Attain Delivery System Flexibility

B201106345med

Detail 
Attain Ability Lead Portfolio

The Attain® CRT implant system works together to help you navigate the most challenging anatomies.

Delivery System Flexibility with Multiple Lead Options

  • Attain Command® catheters – The first catheter family to feature a hydrophilic coating for deep seating
  • Attain Ability® Family of leads – Navigate diverse anatomies with a family of dual electrode leads compatible with Select II sub-selection catheters, featuring a flexible, tapered distal end
  • Attain StarFix® lead – The first active fixation left-heart lead to optimize lead placement in a diverse range of vein locations and sizes
  • Attain Select® II sub-selection catheter – The first 7 Fr catheter capable of delivering a 4 Fr and 5.3 Fr lead directly to branch veins
  • Attain Hybrid® guide wire – The agility of a guide wire with the stability of a stylet in one

The Medtronic Attain integrated system of steerable and fixed shape catheters and over-the-wire leads has been designed to fit your preferences and your patients’ anatomies – even in difficult cases.

Achieve proven clinical performance1-5 with the Attain family of cardiac resynchronization leads and delivery systems.

 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Get There. Stay There. Perform There.

Integrated tools that work together for:

  • Steerability
  • Telescoping
  • Sub-selection

OTW leads with:

  • Multiple fixation options: active, angled body, dual canted, straight with tines
  • Low dislodgement rates1-5
  • Sizes to fit a wide range of anatomies

Proven performance:

  • High implant success rate1-5
  • Low stimulation thresholds1-4
  • Fewer complications due to phrenic nerve stimulation1-5
  • Dual electrode lead design1,3-5
  • Tip seal facilitates reduction of blood ingress1-5

References

  1. Medtronic Attain® Bipolar OTW Model 4194 Lead, Final Clinical Report, Version 1, January 31, 2005.
  2. Attain StarFix® Model 4195 Left Ventricular Lead, FDA IDE Final Report, November 18, 2008.
  3. Medtronic Attain Ability® Model 4196 Left Ventricular Lead, Final Clinical Report, Version 1, February 25, 2009.
  4. Medtronic Attain Ability® Plus 4296 Market Release Report, Version 1, January 20, 2010.
  5. Attain Ability® Straight Model 4396 Left Ventricular Lead, Summary of Clinical Results, February 25, 2011 (M940625A001)
Last updated: 26 Feb 2013

Related Therapy

Heart Failure Management

Medtronic Connect

connect-thumb

Find presentations, animations, videos, photos, and other resources.

More

Medtronic 24-Hour Technical Support

(800) 328-2518