Fully Integrated CRT Implant System
 

Attain Left-Heart Leads

Medtronic offers a broad choice of leads to navigate diverse anatomies to enhance the chance of success during the implant procedure. Designs are available for stability in different vein sizes and programming options to avoid phrenic nerve stimulation.

Medtronic Provides More Options for Left-Heart Leads than Any Other Company, Improving Chances of Implant Success1

Attain-Leads-Fluoro

Detail – Attain Lead Options

Vein-Diameter-Continuumbth

Detail   Attain Lead Family Vein Diameter Continuum

 

Attain® Family of LV Leads

  4194 4195 4196 4296 4396
Compatibility  IS-1  IS-1  IS-1  IS-1  IS-1
OTW Delivery Yes Yes Yes Yes Yes
Stylet Delivery Yes Yes Yes Yes Yes
Distal Lead Diameter 5.4 Fr 5.3 Fr 4.6 Fr 4.6 Fr 4.6 Fr
Proximal Lead Diameter 6.0 Fr 5.0 Fr 4.0 Fr 5.3 Fr 4.0 Fr
Tip Seal Yes Yes Yes Yes Yes
Distal Shape Angled Canted Angled Angled Straight
Fixation Angled Body Deployable Lobes Dual Canted Dual Canted Tined Fixation
Polarity Bipolar Unipolar Bipolar Bipolar Bipolar
Distal ESA 5.8 mm2 5.8 mm2 5.8 mm2 5.8 mm2 5.8 mm2
Proximal ESA 38.0 mm2 NA 5.8 mm2 5.8 mm2 5.8 mm2
Electrode Separation 11.0 mm NA 21.0 mm 21.0 mm 21.0 mm
Lead Lengths 78, 88 cm 78, 88, 103 cm 78, 88 cm 78, 88 cm 78, 88 cm
Compatible with Select II Sub-Selection Catheter No No Yes Yes Yes

 

Reference

  1. Medtronic is the only medical device company to offer an active fixation LV lead and hybrid guide wire. Sources consulted: January 2011: www.bostonscientific.com; www.sjm.com; www.biotronik.com; www.sorin-crm.com.

Attain Ability Left-Heart Lead –
4196 4 Fr, Dual Electrode

The first 4 Fr dual electrode* left-heart lead featuring a flexible, tapered distal end for navigating difficult anatomies. Compatible with Select® II sub-selection catheters.

Attain-4196-Features

Attain Ability® 4196 Lead 

Attain-4196-Venogram
Detail Attain Ability 4196 Option
 

Delivery Flexibility

The Attain Ability 4196 lead can be delivered with a guide wire or stylet. Compatible with:

 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Key Features

  • Dual electrode*
  • Dual canted fixation for enhanced stability
  • Steroid on both electrodes
  • 4.0 Fr proximal lead diameter
  • IS-1 connector
  • Multiple pacing vectors help address phrenic nerve stimulation and prevent need for chronic electrode repositioning
  • Ability to choose the best configuration for threshold optimization during implant and at follow-up

*Dual cathode

Attain-4196-Vectors
Attain Ability 4196 Pacing Vectors
 
Options for CRT-D:
  • LV tip to RV coil
  • LV ring to RV coil
  • LV tip to ring (LV bipolar)
Options for CRT-P:
  • LV ring to can
  • LV tip to can
  • LV tip to RV ring
  • LV ring to RV ring
  • LV tip to LV ring

Medtronic Consulta® and Syncra CRT-P devices


Clinically Proven 2

Study
Endpoint
Implant Success
Rate
Dislodgement
Complications*
Phrenic Nerve
Complications
Mean LV Pacing
Threshold (at 0.5 ms)
1 month96.4%4.5%0%1.1 V ± 0.9 V
(LV tip/RV coil)
1.9 V ± 2.0 V
(LV ring/RV coil)

* Complications are defined as adverse events that require invasive intervention

NASA Technology

Insulation used in the Attain Ability family of leads was developed by NASA for use in harsh environments.

  • Unique SI Polyimide insulation material licensed by Medtronic from NASA
  • High resistance to heat, moisture, and chemicals
Nasa-Technology-Close-up

NASA Technology Insulation

 

References

  1. Giannola G, Lacopino S, Lombardo E, et al. Efficacy of a tool combining guide-wire and stylet for the left ventricular lead positioning. Europace. February 2011:244-250.
  2. Medtronic Attain Ability® Model 4196 Left Ventricular Lead, Final Clinical Report, Version 1, February 25, 2009, Medtronic, Inc.

Attain Ability Plus Left-Heart Lead –
4296 5.3 Fr, Dual Electrode

  • The first 5.3 Fr dual electrode* left-heart lead that can be delivered with a sub-selection catheter (leads ≥ 88 cm length)
  • Stable – designed to reach and maintain target vein position1

*Dual cathode

Attain-4296-Features

Attain Ability® 4296 Lead

Attain-4296-Venogramlg
Attain Ability 4296 Option

Delivery Flexibility

The Attain Ability 4296 lead can be delivered with a guide wire or stylet. Compatible with:

  • Attain Command® catheters, the first family of catheters to feature a hydrophilic coating
  • Attain Select® II sub-selection catheters, enabling direct-to-vessel delivery for deep seating in difficult anatomies (in leads ≥ 88 cm length)
  • Attain Hybrid® guide wire (GWR 4196), proven to reduce implantation time and improve access to target vein LV lead positioning1

 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Key Features

  • Dual electrode*
  • Dual canted fixation for enhanced stability
  • Steroid on both electrodes
  • 5.3 Fr proximal lead diameter
  • IS-1 connector
  • Multiple pacing vectors help address phrenic nerve stimulation and prevent need for chronic electrode repositioning
  • Ability to choose the best configuration for threshold optimization during implant and at follow-up

*Dual cathode

Attain-4296-Vectors.
Attain Ability 4296 Pacing Vectors
 
Options for CRT-D:
  • LV tip to RV coil
  • LV ring to RV coil
  • LV tip to ring (LV bipolar)
Options for CRT-P:
  • LV ring to can
  • LV tip to can
  • LV tip to RV ring
  • LV ring to RV ring
  • LV tip to LV ring

Medtronic Consulta® and Syncra CRT-P devices


Clinically Proven 2

Study
Endpoint
Implant
Success Rate
Dislodgement
Complications*
Phrenic Nerve
Complications
Mean LV Pacing
Threshold (at 0.5 ms)
1 month 92.9% 1.3% 0% 0.9 V ± 0.6 V
(LV tip/RV coil)

1.6 V ± 1.8 V
(LV ring/RV coil)

* Complications are defined as adverse events that require invasive intervention

NASA Technology

Insulation used in the Attain Ability family of leads was developed by NASA for use in harsh environments.

  • Unique SI Polyimide insulation material licensed by Medtronic from NASA
  • High resistance to heat, moisture, and chemicals
Nasa-Technology-Close-up

NASA Technology Insulation

 

References

  1. Giannola G, Lacopino S, Lombardo E, et al. Efficacy of a tool combining guide-wire and stylet for the left ventricular lead positioning. Europace. February 2011:244-250.
  2. Medtronic Attain Ability® Plus 4296 Market Release Report, Version 1, January 20, 2010, Medtronic, Inc.

Attain Ability Straight Left-Heart Lead –
4396 4 Fr, Dual Electrode

  • The first 4 Fr straight dual electrode left-heart lead facilitates maneuvering through small venous anatomies1
  • The lead’s flexible tapered distal end, combined with the agility of the Attain Hybrid® guide wire, enhance trackability and control1

*Dual cathode

 

Attain-4396-Features

Attain Ability® 4396 Lead

Attain-4396-Venogramlg
Attain Ability 4396 Option

Delivery Flexibility

The Attain Ability 4396 lead can be delivered with a guide wire or stylet. Compatible with:

 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Key Features

  • Dual electrode*
  • Straight with tined fixation
  • Steroid on both electrodes
  • 4.0 Fr proximal lead diameter
  • IS-1 connector
  • Multiple pacing vectors help address phrenic nerve stimulation and prevent need for chronic electrode repositioning
  • Ability to choose the best configuration for threshold optimization during implant and at follow-up

*Dual cathode

Attain Ability 4396 Pacing Vectors

Options for CRT-D:
  • LV tip to RV coil
  • LV ring to RV coil
  • LV tip to ring (LV bipolar)
Options for CRT-P:
  • LV tip to can
  • LV tip to RV ring
  • LV tip to LV ring
  • LV ring to can
  • LV ring to RV ring

Medtronic Consulta® and Syncra CRT-P devices


Clinically Proven 2

96.8% of physicians positively rated the handling of the 4396 lead and the ability to maneuver it to the desired cardiac veins in their patients.

Study
Endpoint
Implant
Success Rate
Dislodgement
Complications*
Phrenic Nerve
Complications
Mean LV Pacing
Threshold (at 0.5 ms)
1 month92.9%3.2%1.3%1.6 V ± 1.5 V at 1 mon
(LV tip/RV coil)
2.7 V ± 2.4 V at 3 mons
(LV ring/RV coil)

* Complications are defined as adverse events that require invasive intervention

Attention: In the 4396 clinical study, 14 of 106 subjects (13.2%) had pacing capture thresholds (PCT) ≥ 3.0 V (measured at 0.5 ms at 3 months). PCT ≥ 3.0 V can be associated with phrenic nerve stimulation, battery depletion, and loss of capture. The Model 4396 lead provides a straight tip, tined fixation, and small diameter, which may be needed for some patients. See the technical manual for more information.

NASA Technology

Insulation used in the Attain Ability family of leads was developed by NASA for use in harsh environments.

  • Unique SI Polyimide insulation material licensed by Medtronic from NASA
  • High resistance to heat, moisture, and chemicals
Nasa-Technology-Close-up

Multiple Layers
NASA Technology Insulation

 

References

  1. Giannola G, Lacopino S, Lombardo E, et al. Efficacy of a tool combining guide-wire and stylet for the left ventricular lead positioning. Europace. February 2011:244-250.
  2. Attain Ability® Straight Model 4396 Left Ventricular Lead, Summary of Clinical Results, February 25, 2011 (M940625A001), Medtronic, Inc.

 

Attain Bipolar OTW Left-Heart Lead –
4194 6 Fr

Designed for medium to large veins with moderate tortuosity.

Attain-4194Featth

Attain 4194 Lead

 
Attain-4194-Venogramlg
Attain 4194 Option
 

Delivery Flexibility

The Attain Bipolar OTW 4194 lead can be delivered with a guide wire or stylet. Compatible with the:

 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Key Features

  • Flexible anode coil designed for easy trackability and pushability in varying venous anatomies
  • Angled distal end designed for steerability and stable fixation
  • Steroid eluting
  • Tip seal allows acute guide wire re-insertion and minimizes blood ingress
    • Available in 78 cm and 88 cm lengths
    • Bipolar
    • 6.0 Fr proximal lead diameter
    • IS-1 Connector


Clinically Proven 1

Study Endpoint Implant
Success Rate
Dislodgement
Complications*
Phrenic Nerve
Complications
Mean LV Pacing
Threshold
(at 0.5 ms)
3 months 87.8% 2.1% 0.5% 1.6 V ± 1.1 V

*Complications are defined as adverse events that require invasive intervention.

Reference

  1. Medtronic Attain® Bipolar OTW Model 4194 Lead, Final Clinical Report, Version 1, January 31, 2005, Medtronic, Inc.

 

Attain StarFix Left-Heart Lead –
4195 5 Fr, Unipolar

Attain StarFix® LV lead is the first active fixation left-heart lead with a 0% chronic dislodgement rate (chronic defined as two days or longer post-implant).

  • Active fixation left-heart lead with exclusive deployable lobes, allowing for customized lead placement in a wide range of vein sizes and locations
  • The 0% chronic dislodgement rate is supported by one of the industry’s largest left-heart lead clinical studies involving 385 implants followed for up to four years1
Attain-4195-Features
Detail Attain StarFix Leads
 
Attain-4195-Venogramlg
Attain StarFix Option
 

Delivery Flexibility

The Attain StarFix lead can be delivered with a guide wire or stylet. Compatible with:

 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Key Features

  • Exclusive deployable lobes expand to 24 Fr, allowing customized lead placement in a wide range of vein sizes and locations
  • 0% chronic dislodgement rate supported by left-heart lead studies involving 385 implants followed for up to four years1
    • 5 Fr proximal lead body
    • Unipolar
    • Steroid eluting
    • Polyurethane insulation
    • IS-1 connector


Clinically Proven 1

Study
Endpoint
Implant
Success Rate
Dislodgement
Complications*
Phrenic Nerve
Complications
Mean LV Pacing
Threshold
(at 0.5 ms)
3 months94.4%0.7%2.7%1.3 V ± 0.8 V

*Complications are defined as adverse events that require invasive intervention.

Reference

  1. Attain StarFix Model 4195 Left Ventricular Lead, FDA IDE Final Report, November 18, 2008, Medtronic, Inc.
Last updated: 26 Feb 2013