Secura DR and VR
ICD Defibrillators

Secura® DR and VR ICD defibrillators for tachycardia therapy are part of the Vision 3D™ Portfolio and include Complete Capture Management and OptiVol® Fluid Status Monitoring for predicting worsening heart failure.

Vision 3D Fundamentals

Vision 3D Fundamentals

Vision 3D Portfolio for Individual Patient Needs

Cube-image

Vision 3D™ Fundamentals are the foundation of the Vision 3D Portfolio, a comprehensive family of ICD defibrillators and biventricular devices to meet your individual patient's therapy goals.

Vision 3D Fundamentals include:

  • Proven cardioverter shock reduction and atrial therapy1
  • Dual chamber managed ventricular pacing2
  • Industry-leading diagnostics and reporting such as Cardiac Compass®
  • Medtronic Conexus® wireless remote cardiac telemetry, part of Medtronic CareLink® Network

References

  1. Wathen MS, DeGroot PJ, Sweeny MO, et al, for the PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. October 26, 2004;110(17):2591-2596.
  2. Gillis AM, Pürerfellner H, Israel CW, et al. Reduction of unnecessary ventricular pacing due to the Managed Ventricular Pacing (MVP) mode in pacemaker patients: benefit for both sinus node disease (SND) and AV block (AVB) indications. Heart Rhythm. 2005;Abstract AB21-1.

 

Secura ICD Defibrillators -

Proven Solutions for Tachycardia Therapy

The first and only completely automatic, wireless ICD defibrillators to combine industry-leading pacing, wireless remote cardiac telemetry, and ICD defibrillator exclusives:

Important Safety Information

Changes in a patient’s disease and/or medications may alter the efficacy of a device’s programmed parameters or related features.

Completely Automatic – Complete Capture Management

Secura ICD defibrillators include Complete Capture Management which:

  • Ensures capture in all heart chambers – atrial capture management, left ventricular capture management, and right ventricular capture management
  • Provides a daily complete device check – automatically:
    • Lead impedance
    • Battery status
    • All-chamber threshold evaluation
    • Sensing amplitudes
  • Eliminates the need for manual threshold checks, freeing time for your clinic patients
  • Adapts therapies automatically to changing patient needs

Timely, Efficient Follow-up With Wireless Remote Cardiac Telemetry

The same in-depth device information as an office visit:

Programmable SCV

Programming flexibility reduces risks for patients

Programmable Options Provide Noninvasive Solutions for
Complex Cases

  • Choose a different vector to resolve sensing issues that may lead to unnecessary cardioverter shocks using programmable RV sensing
  • Avoid surgical intervention and enhance safety for your patients with high DFTs using Programmable SVC and Active Can®

References

  1. Medtronic Secura™ ICD System Reference Guide
  2. Gillis AM, Pürerfellner H, Israel CW, et al. Reduction of unnecessary ventricular pacing due to the Managed Ventricular Pacing (MVP) mode in pacemaker patients: benefit for both sinus node disease (SND) and AV block (AVB) indications. Heart Rhythm. 2005;Abstract AB21-1.

Secura ICD Defibrillators

Vision 3D Fundamentals

Vision 3D Fundamentals

Secura DR ICD Defibrillator

  • 7.7 seconds BOS*
  • 9.2 seconds RRT**
  • 7.6 years longevity1
  • 37 cc, 68 g

Secura VR ICD Defibrillator

  • 7.7 seconds BOS*
  • 9.4 seconds RRT **
  • 8.8 years longevity2
  • 37 cc, 68 g

See the Medtronic Secura ICD Defibrillator Clinician Manual.
 

* Beginning of Service
** Recommended Replacement Time

References

  1. 50% atrial and 5% ventricular pacing in MVP Mode at 60 ppm, 2.5 V, 0.4 ms, 600 ohms; pre-arrhythmia EGM storage off; 2 full energy charges per year.
  2. 15% VVI at 60 ppm, 2.5 V, 0.4 ms, 600 ohms; pre-arrhythmia EGM storage off; 2 full energy charges per year.
Last updated: 22 Sep 2010

Featured Product

Learn more about Sprint Quattro ICD Leads.

For Your Patients

Ask the ICD website

An interactive experience that answers basic questions about ICDs.

Go to Ask the ICD website

Medtronic Manual Library

manuals-medtronic-com

Find instructions for use and product manuals.

More
 

Medtronic Academy

Medtronic Academy

Access a wide range of interactive courses, case studies, videos and presentations.

More

Medtronic 24-Hour Technical Support

(800) 328-2518