Sherpa NX Balanced Coronary Guide Catheter
The Sherpa NX™ Balanced Coronary Guide Catheter is your solution for procedures that require consistent and durable performance.
How the Sherpa NX Balanced Catheter Works
Percutaneous Coronary Intervention (PCI), also known as coronary angioplasty, is a therapeutic procedure to treat the narrowed or stenotic section of the coronary artery of the heart due to coronary atherosclerosis. The guide catheter provides support for device advancement (stents, balloons etc.). It is the conduit for device and wire transport, a vehicle for contrast injection and takes measurements. Guide catheters are available in a variety of shapes and sizes to fit a variety of patient anatomies.
Specifications
The Sherpa NX Balanced catheter has a flexible distal segment for manipulation if required.
Trusted Performance From Hub to Tip
- Workhorse performance suitable for various anatomies
- Soft tip and distal sleeve enables manipulation
- Advanced HDPE liner provides smooth, low-friction device passage
Full-Wall Technology Construction
- Robust, thinner walls without compromising support or curve retention
Full Range of Coronary and Peripheral Curves
- 6F–8F sizes available
- Specialty curves available
- Custom lengths and custom curve programs available
The Sherpa NX Balanced catheter is available in 6F, 7F and 8F with the following inner diameter measurements:
| Sherpa NX Balanced | |
|---|---|
| 6F | 0.070" |
| 7F | 0.080" |
| 8F | 0.088" |
Detail Sherpa NX Balanced 6F | 6F
|
Detail Sherpa NX Balanced 7F | 7F
|
Detail Sherpa NX Balanced 8F | 8F
|
Ordering Information
6F Sherpa NX Balanced Guide Catheters
| LEFT CORONARY CURVES | Backup Support Left | ||||
|---|---|---|---|---|---|
| Left Standard (JL) | Short Left (SL) | JCL | Amplatz Left | Short Amplatz Left | EBU |
| SB6JL30 | SB6SL30 | SB6JCL30 | SB6AL75 | SB6SAL75 | SB6EBU30 |
| SB6JL35 | SB6SL35 | SB6JCL35 | SB6AL10 | SB6SAL10 | SB6EBU35 |
| SB6JL40 | SB6SL40 | SB6JCL40 | SB6AL10D* | SB6SAL15 | SB6EBU35D* |
| SB6JL40P^ | SB6SL45 | SB6JCL45 | SB6AL15 | SB6SAL20 | SB6EBU375 |
| SB6JL45 | SB6SL50 | SB6JCL50 | SB6AL20 | SB6SAL25 | SB6EBU40 |
| SB6JL50 | SB6SL60 | SB6AL25 | SB6SAL30 | SB6EBU45 | |
| SB6JL60 | SB6AL30 | SB6SAL40 | SB6EBU50 | ||
| SB6AL40 | |||||
| Left Standard (FL) | |||||
| SB6FL40 | |||||
| SB6FL40G^^ | |||||
| SB6FL40P^ | |||||
| RIGHT CORONARY CURVES | |||||
| Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
| SB6JR30 | SB6SR30 | SB6JCR35 | SB6AR10 | SB6SCR35 | SB6RBU35 |
| SB6JR35 | SB6SR35 | SB6JCR40 | SB6AR20 | SB6SCR40 | SB6RBU40 |
| SB6JR40 | SB6SR40 | SB6JCR45 | SB6ALR12 | SB6SCR50 | SB6RBU45 |
| SB6JR40D* | SB6SR45 | SB6JCR50 | |||
| SB6JR40P^ | SB6SR50 | Short Amplatz Right | ECR | ||
| SB6JR45 | SB6SR60 | SB6SAR10 | SB6ECR30 | ||
| SB6JR50 | SB6SAR20 | SB6ECR35 | |||
| SB6JR60 | SB6ECR40 | ||||
| SB6ECR45 | |||||
| Right Standard (FR) | |||||
| SB6FR40 | 3-Dimensional | ||||
| SB6FR40G^^ | SB63DRC | ||||
| SB6FR40P^ | SB63DRIGHT | ||||
| OTHER CURVES | |||||
| Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Peripheral | Radial Specialty |
| SB6MB1 | SB6MAC30 | SB6IMA | SB6CHAMP05 | SB6CHAMP15K+ | SB6LARA |
| SB6MB1D* | SB6MAC35 | SB6IMAD* | SB6CHAMP10 | SB6CHAMP20K+ | SB6MRADIAL |
| SB6MB2 | SB6MAC375 | SB6LCB | SB6CHAMP15 | SB6CHAMP25K+ | SB6MRESS |
| SB6MP1 | SB6MAC40 | SB6LCBD* | SB6CHAMP20 | SB6IMAK+ | SB6RRAD |
| SB6MP1D* | SB6MAC45 | SB6RCB | SB6CHAMP25 | SB6JR40K+ | |
| SB6MP2 | SB6MAC50 | SB6RCBD* | SB6CHAMP30 | SB6MPHK+ | NOTO |
| SB6MPST | SB6RCBII | SB6CHAMP35 | SB6MP1K+ | SB6NOTO | |
| SB6HSI | SB6CHAMP40 | SB6PK1W++ | |||
| SB6HSID* | SB6SCR40K+ | EL GAMAL | |||
| SB6HSII | SB6RDCK+ | SB6ELGAMAL | |||
| SB6RMHSII | |||||
| SB6HSIII | |||||
Shaft Diameter: 6F
K+=55 cm Shaft length
Inner Diameter: 0.070 in.
W++=47 cm shaft length
P^=Posterior
To order curves with sideholes, please add "SH" to end of model number
G^^=Anterior
5 packs available in select curves
7F Sherpa NX Balanced Guide Catheters
| LEFT CORONARY CURVES | Backup Support Left | ||||
|---|---|---|---|---|---|
| Left Standard (JL) | Short Left (SL) | JCL | Amplatz Left | Short Amplatz Left | EBU |
| SB7JL30 | SB7SL30 | SB7JCL30 | SB7AL75 | SB7SAL75 | SB7EBU30 |
| SB7JL35 | SB7SL35 | SB7JCL35 | SB7AL10 | SB7SAL10 | SB7EBU35 |
| SB7JL40 | SB7SL40 | SB7JCL40 | SB7AL15 | SB7SAL15 | SB7EBU375 |
| SB7JL40D* | SB7SL45 | SB7JCL45 | SB7AL20 | SB7SAL20 | SB7EBU40 |
| SB7JL40P^ | SB7SL50 | SB7JCL50 | SB7AL25 | SB7SAL25 | SB7EBU40D* |
| SB7JL45 | SB7SL60 | SB7AL30 | SB7SAL30 | SB7EBU45 | |
| SB7JL50 | SB7AL40 | SB7SAL40 | SB7EBU50 | ||
| SB7JL60 | SB7EBU50 | ||||
| RIGHT CORONARY CURVES | |||||
| Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
| SB7JR30 | SB7SR30 | SB7JCR35 | SB7AR10 | SB7SCR35 | SB7RBU35 |
| SB7JR35 | SB7SR35 | SB7JCR40 | SB7AR20 | SB7SCR40 | SB7RBU40 |
| SB7JR40 | SB7SR40 | SB7JCR45 | SB7ALR12 | SB7SCR50 | SB7RBU45 |
| SB7JR40D* | SB7SR45 | SB7JCR50 | |||
| SB7JR40P^ | SB7SR50 | ECR | |||
| SB7JR45 | SB7SR60 | SB7ECR35 | |||
| SB7JR50 | SB7ECR40 | ||||
| SB7JR60 | Short Amplatz Right | SB7ECR45 | |||
| SB7SAR10 | |||||
| FCR | SB7SAR20 | ||||
| SB7FCR35 | 3-Dimensional | ||||
| SB7FCR40 | SB73DRC | ||||
| SB73DRIGHT | |||||
| OTHER CURVES | |||||
| Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Peripheral | NOTO |
| SB7HSI | SB7MAC30 | SB7IMA | SB7CHAMP05 | SB7CHAMP15K+ | SB7NOTO |
| SB7HSII | SB7MAC35 | SB7IMAD* | SB7CHAMP10 | SB7CHAMP20K+ | |
| SB7RMHSII | SB7MAC375 | SB7LCB | SB7CHAMP15 | SB7CHAMP25K+ | |
| SB7HSIII | SB7MAC40 | SB7LCBD* | SB7CHAMP20 | SB7IMAK+ | EL GAMAL |
| SB7MB1 | SB7MAC45 | SB7RCB | SB7CHAMP25 | SB7JR40K+ | SB7ELGAMAL |
| SB7MB2 | SB7MAC50 | SB7RCBD* | SB7CHAMP30 | SB7MP1K+ | |
| SB7MP1 | SB7RCBII | SB7CHAMP35 | SB7MPHK+ | ||
| SB7MPST | SB7CHAMP40 | SB7PK1W++ | |||
| SB7SCR40K+ | |||||
| SB7RDCK+ | |||||
| SB7STRAIGHT | |||||
Shaft Diameter: 7F
K+ = 55 cm shaft length
Inner Diameter: 0.080 in.
W++=47 cm shaft length
P^= Posterior
To order curves with sideholes, please add “SH” to end of model number
G^^= Anterior
5 packs available in select curves
8F Sherpa NX Balanced Guide Catheters
| LEFT CORONARY CURVES | Backup Support Left | ||||
|---|---|---|---|---|---|
| Left Standard (JL) | Short Left (SL) | JCL | Amplatz Left | Short Amplatz Left | EBU |
| SB8JL30 | SB8SL30 | SB8JCL30 | SB8AL75 | SB8SAL75 | SB8EBU30 |
| SB8JL35 | SB8SL35 | SB8JCL35 | SB8AL10 | SB8SAL10 | SB8EBU35 |
| SB8JL40 | SB8SL40 | SB8JCL40 | SB8AL10D* | SB8SAL15 | SB8EBU375 |
| SB8JL40D* | SB8SL45 | SB8JCL45 | SB8AL15 | SB8SAL20 | SB8EBU40 |
| SB8JL45 | SB8SL50 | SB8JCL50 | SB8AL20 | SB8SAL25 | SB8EBU45 |
| SB8JL50 | SB8SL60 | SB8AL25 | SB8SAL30 | SB8EBU50 | |
| SB8JL60 | SB8AL30 | SB8SAL40 | |||
| SB8JL70 | SB8AL40 | ||||
| SB8JL80 | SB8AL40D* | ||||
| SB8AL50 | |||||
| Left Standard (FL) | |||||
| SB8FL30 | |||||
| SB8FL35 | |||||
| SB8FL40 | |||||
| SB8FL45 | |||||
| SB8FL50 | |||||
| SB8FL60 | |||||
| RIGHT CORONARY CURVES | |||||
| Right Standard | Short Right | JCR | Amplatz Right | Shepherd's Crook Right | Backup Support Right |
| SB8JR30 | SB8SR30 | SB8JCR35 | SB8AR10 | SB8SCR35 | SB8RBU35 |
| SB8JR35 | SB8SR35 | SB8JCR40 | SB8AR20 | SB8SCR40 | SB8RBU40 |
| SB8JR40 | SB8SR40 | SB8JCR40 | SB8ALR12 | SB8SCR50 | SB8RBU425 |
| SB8JR40D* | SB8SR45 | SB8JCR45 | SB8RBU45 | ||
| SB8JR45 | SB8SR50 | SB8JCR50 | SB8RBU50 | ||
| SB8JR50 | SB8SR60 | ||||
| SB8JR60 | ECR | ||||
| SB8ECR35 | |||||
| SB8ECR35 | |||||
| Right Standard (FR) | Short Amplatz Right | SB8ECR40 | |||
| SB8FR30 | SB8SAR10 | SB8ECR45 | |||
| SB8FR35 | SB8SAR20 | SB8ECR50 | |||
| SB8FR40 | |||||
| SB8FR50 | 3-Dimensional | ||||
| SB8FR60 | SB83DRC | ||||
| SB83DRIGHT | |||||
| OTHER CURVES | |||||
| Multipurpose | MAC (Multi-Aortic) | Bypass | Champ | Peripheral | NOTO |
| SB8HSI | SB8MAC30 | SB8IMA | SB8CHAMP05 | SB8CARL3D* | SB8NOTO |
| SB8HSII | SB8MAC35 | SB8IMAD* | SB8CHAMP10 | SB8CARLD* | |
| SB8RMHSII | SB8MAC375 | SB8LCB | SB8CHAMP15 | SB8CHAMP05K+ | |
| SB8HSIII | SB8MAC40 | SB8LCBD* | SB8CHAMP20 | SB8CHAMP10K+ | |
| SB8MB1 | SB8MAC45 | SB8RCB | SB8CHAMP25 | SB8CHAMP15K+ | |
| SB8MB1D* | SB8MAC50 | SB8RCBD* | SB8CHAMP30 | SB8CHAMP20K+ | |
| SB8MB2 | SB8RCBII | SB8CHAMP35 | SB8CHAMP25K+ | ||
| SB8MB2D* | SB8CHAMP40 | SB8IMAK+ | EL GAMAL | ||
| SB8MP1 | SB8JR40K+ | SB8ELGAMAL | |||
| SB8MPST | SB8MP1K+ | SB8ELGAMAL2 | |||
| SB8MPHK+ | SB8ELGAMAL3 | ||||
| SB8PK1W++ | |||||
| SB8RDCK+ | |||||
| SB8SCR40K+ | |||||
| SB8SW1 |
D* = 90 cm shaft length
Shaft Diameter: 8F
K+ = 55 cm shaft length
Inner Diameter: 0.088 in.
W++=47 cm shaft length
To order curves with sideholes, please add “SH” to end of model number
5 packs available in select curves