Bipolar Sealers
The Aquamantys® System and bipolar sealers feature innovative Transcollation® technology, a combination of radiofrequency (RF) energy and saline that provides hemostatic sealing of soft tissue and bone during surgery.
Aquamantys Generator
The Aquamantys System consists of a proprietary radiofrequency (RF) generator that delivers Transcollation technology to disposable Aquamantys bipolar sealers.
Features of the Aquamantys Generator include:
- Simultaneous RF power and saline delivery
- Power settings from 20–200 watts
- Automatic settings for saline flow rate based on power setting
- Ability to select three different flow rate settings
- Convenient priming mode
Only disposable devices and accessories specifically recommended by Medtronic Advanced Energy may be used with Aquamantys generators.
SBS 5.0 Sheathed Bipolar Sealer
The SBS 5.0 Sheathed Bipolar Sealer with retractable sheath for use near sensitive tissue
Managing both cut muscle and epidural bleeding may require the use of multiple devices/modalities. The Aquamantys SBS 5.0 Sheathed Bipolar Sealer was designed to optimize speed and continuity of surgical cases by treating both of these needs with one device.
- Delivers Transcollation technology, which has been shown to reduce blood loss during spine surgery1
- Flat-tipped electrodes allow for compression of epidural veins
- Retractable sheath enables simultaneous retraction and electrode use near sensitive tissue such as dura and nerve roots (sheath closed) and hemostatic sealing of soft tissue and bone (sheath open)
Clinical Benefits
Transcollation technology provides the following clinical benefits when used during spinal surgery:
- Decreases blood loss per level fused1
- May help improve visibility in the surgical field2,3
- Prevents and stops epidural bleeding near critical structures3
- Decreases surgical time2
Surgical Applications
The Aquamantys SBS 5.0 Sheathed Bipolar Sealer is commonly used in open or MIS 1- or 2-level instrumented fusions.
For more information about the Aquamantys SBS 5.0 Sheathed Bipolar Sealer, contact Medtronic Advanced Energy or your local sales representative.
Product Specifications:
| Electrode length | Electrode diameter | Center to center spacing between electrodes | Angle between body center line and straight portion shaft | Out of body shaft length | Distal bayonet shaft length |
|---|---|---|---|---|---|
| 3.56mm (.140”) | 2.03mm (.080”) | 2.79mm (.110”) | 15 degrees | 172.50mm (6.79”) | 139.95mm (5.51”) |
Ordering Information:
| Description | Catalog Number |
|---|---|
| Aquamantys SBS 5.0 Sheathed Bipolar Sealer | 23-312-1 |
References
- Mankin KP, Moore CA, Miller LE et al. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis. J Spinal Disorders & Techniques, October 2011; doi:10.1097/BSD.0b013e3182334ec5.
- Snyder BD, Hedequist D, Shannon E. Bipolar sealing technology to control bleeding in pediatric spine surgery: a retrospective study. Poster presentation at Pediatric Orthopaedic Society of North America Annual Meeting 2007; Hollywood, FL.
- Santiago P. Controlling epidural bleeding and improving visibility during spinal surgery with a novel bipolar sealing technology: a case report. Company funded, non-peer-reviewed Medtronic white paper, 2009.
Mini EVS 3.4 Epidural Vein Sealer
The Mini EVS has a 3.4 mm tip for small epidural access points
Bleeding in the epidural space can compromise visibility and add frustration to an otherwise predictable case. Like the Epidural Vein Sealer, the Aquamantys Mini EVS 3.4 is an innovative handpiece that addresses this challenge.
Designed to optimize visibility and control epidural bleeding, the Aquamantys Mini EVS 3.4 enables you to prophylactically compress and treat epidural veins before they begin to bleed.
- Delivers Transcollation technology, which has been shown to reduce blood loss during spine surgery1
- Insulated shaft enables simultaneous retraction and electrode use near sensitive tissue such as dura and nerve roots
- 3.4 mm tip size accommodates small epidural access points
Clinical Benefits
Transcollation technology provides the following clinical benefits when used during spine surgery:
- Prevents and stops epidural bleeding near critical structures2
- May help improve visibility in the surgical field1,2
- Decreases surgical time1
- Decreases blood loss per level fused3
Surgical Applications
- Decompression procedures (discectomy, laminectomy, and others)
- Procedures requiring access to the epidural space (PLIF, TLIF, PCDF, and others)
For more information about the Aquamantys Mini EVS 3.4, contact Medtronic Advanced Energy or your local sales representative.
Product Specifications and Comparison:
| Shaft diameter | Electrode diameter | Spacing between electrodes | Angle between body center line and straight portion of shaft | Out of body shaft length | Distal bayonet shaft length | |
|---|---|---|---|---|---|---|
| Mini EVS 3.4 | 3.4mm (.134”) | 3.4mm (.134”) | .64mm (.025”) | 15 degrees | 172.50mm (6.79”) | 139.45mm (5.49”) |
| EVS | 4mm (.156”) | 4mm (.156”) | .64mm (.025”) | 15 degrees | 172.50mm (6.79”) | 139.45mm (5.49”) |
Ordering Information:
| Description | Catalog Number |
|---|---|
| Aquamantys Mini EVS 3.4 Epidural Vein Sealer | 23-314-1 |
References
- Snyder BD, Hedequist D, Shannon E. Bipolar sealing technology to control bleeding in pediatric spine surgery: a retrospective study. Poster presentation at Pediatric Orthopaedic Society of North America Annual Meeting 2007; Hollywood, FL.
- Santiago P. Controlling epidural bleeding and improving visibility during spinal surgery with a novel bipolar sealing technology: a case report. Company funded, non-peer-reviewed Medtronic white paper, 2009.
- Mankin KP, Moore CA, Miller LE et al. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis. J Spinal Disorders & Techniques, October 2011; doi:10.1097/BSD.0b013e3182334ec5.
2.3 Bipolar Sealer
Bipolar Sealer with 2.3 mm electrode tips for precise application
The Aquamantys 2.3 Bipolar Sealer uses proprietary Transcollation technology, which has been clinically shown to reduce blood transfusion rates by minimizing intra-and post-operative blood loss.1
Product Features and Benefits
- Dual electrode configuration enables painting motion to provide hemostatic sealing across broad planes of tissue
- 2.3 mm electrode size delivers more precise application of Transcollation technology
- Bipolar technology alleviates need for grounding pad
Clinical Benefits
Transcollation technology provides the following clinical benefits when used during spinal surgery:
- Decreases blood loss per level fused1
- May help improve visibility in the surgical field2,3
- Decreases surgical time3
Surgical Applications
The Aquamantys 2.3 Bipolar Sealer is commonly used in the following procedures:
- Multilevel Posterior Instrumented Fusions or Multilevel PLIF and TLIF, Scoliosis
- ALIF
For more information about the Aquamantys 2.3 Bipolar Sealer, contact Medtronic Advanced Energy or your local sales representative.
Product Specifications:
| Electrode length | Electrode diameter | Center to center spacing between electrodes | Angle at tip | Out of body shaft length |
|---|---|---|---|---|
| 5.74mm (.226”) | 2.34mm (.092”) | 4.40mm (.173”) | 30 degrees | 129.54mm (5.1”) |
Ordering Information:
| Description | Catalog Number |
|---|---|
| Aquamantys 2.3 Bipolar Sealer | 23-113-1 |
References
- Mankin KP, Moore CA, Miller LE et al. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis. J Spinal Disorders & Techniques, October 2011; doi:10.1097/BSD.0b013e3182334ec5.
- Santiago P. Controlling epidural bleeding and improving visibility during spinal surgery with a novel bipolar sealing technology: a case report. Company funded, non-peer-reviewed Medtronic white paper, 2009.
- Snyder BD, Hedequist D, Shannon E. Bipolar sealing technology to control bleeding in pediatric spine surgery: a retrospective study. Poster presentation at Pediatric Orthopaedic Society of North America Annual Meeting 2007; Hollywood, FL.
6.0 Bipolar Sealer
6.0 Bipolar Sealer with dual electrode pad for hemostatic sealing of broad tissue planes
The Aquamantys 6.0 Bipolar Sealer uses proprietary Transcollation technology to minimize intra- and post-operative blood loss, resulting in reduced transfusion rates for patients.1
Product Features and Benefits
- Delivers controlled thermal energy to tissue, which provides hemostatic sealing without the charring associated with standard electrosurgical devices
- Dual electrode configuration enables painting motion to provide hemostatic sealing across broad planes of tissue
- Bipolar technology alleviates need for grounding pad
Clinical Benefits
Transcollation technology provides the following clinical benefits when used during spinal surgery:
- Decreases blood loss per level fused1
- May help improve visibility in the surgical field2,3
- Decreases surgical time3
Surgical Applications
The Aquamantys 6.0 Bipolar Sealer is commonly used in the following procedures:
- Multilevel Posterior Instrumented Fusions or Multilevel PLIF and TLIF, Scoliosis
- ALIF
For more information about the Aquamantys 6.0 Bipolar Sealer, contact Medtronic Advanced Energy or your local sales representative.
Product Specifications:
| Electrode length | Electrode diameter | Center to center spacing between electrodes | Angle at tip | Out of body shaft length |
|---|---|---|---|---|
| 5.74mm (.226”) | 3.48mm (.137”) | 6.0mm (.236”) | 30 degrees | 129.54mm (5.1”) |
Ordering Information:
| Description | Catalog Number |
|---|---|
| Aquamantys 6.0 Bipolar Sealer | 23-112-1 |
References
- Mankin KP, Moore CA, Miller LE et al. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis. J Spinal Disorders & Techniques, October 2011; doi:10.1097/BSD.0b013e3182334ec5.
- Santiago P. Controlling epidural bleeding and improving visibility during spinal surgery with a novel bipolar sealing technology: a case report. Company funded, non-peer-reviewed Medtronic white paper, 2009.
- Snyder BD, Hedequist D, Shannon E. Bipolar sealing technology to control bleeding in pediatric spine surgery: a retrospective study. Poster presentation at Pediatric Orthopaedic Society of North America Annual Meeting 2007; Hollywood, FL.
Epidural Vein Sealer (EVS)
The Epidural Vein Sealer controls bleeding and optimizes visibility
Bleeding in the epidural space can compromise visibility and add frustration to an otherwise predictable case. The EVS is an innovative handpiece for the Aquamantys System that addresses this challenge.
Designed to optimize visibility and control epidural bleeding, the EVS enables you to prophylactically compress and treat epidural veins before they bleed using patented Transcollation technology.
Product Features and Benefits
- Insulated shaft enables electrode use near sensitive tissue such as dura and nerve roots
- 4.0 mm tip size accommodates small epidural access points
- Flat bipolar electrodes allow for compression of epidural veins
Clinical Benefits
Transcollation technology provides the following clinical benefits when used during spine surgery:
- Prevents and stops epidural bleeding near critical structures1
- May help improve visibility in the surgical field1,2
- Decreases surgical time2
- Decreases blood loss per level fused3
Surgical Applications
- Decompression procedures (discectomy, laminectomy, and others)
- Procedures requiring access to the epidural space (PLIF, TLIF, PCDF, and others)
For more information about the Epidural Vein Sealer, contact Medtronic Advanced Energy or your local sales representative.
Product Specifications:
| Shaft diameter | Electrode diameter | Spacing between electrodes | Angle between body center line and straight portion of shaft | Out of body shaft length | Distal bayonet shaft length |
|---|---|---|---|---|---|
| 4mm (.156”) | 4mm (.156”) | .64mm (.025”) | 15 degrees | 172.50mm (6.79”) | 139.45mm (5.49”) |
Ordering Information:
| Description | Catalog Number |
|---|---|
| Aquamantys Epidural Vein Sealer | 23-121-1 |
References
- Santiago P. Controlling epidural bleeding and improving visibility during spinal surgery with a novel bipolar sealing technology: a case report. Company funded, non-peer-reviewed Medtronic white paper, 2009.
- Snyder BD, Hedequist D, Shannon E. Bipolar sealing technology to control bleeding in pediatric spine surgery: a retrospective study. Poster presentation at Pediatric Orthopaedic Society of North America Annual Meeting 2007; Hollywood, FL.
- Mankin KP, Moore CA, Miller LE et al. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis. J Spinal Disorders & Techniques, October 2011; doi:10.1097/BSD.0b013e3182334ec5.
Malleable Bipolar Sealer with Light (MBS)
Malleable Bipolar Sealer with Light enables access and visualization in hard-to-reach anatomy
The MBS provides illumination and hemostatic sealing of soft tissue and bone not easily accessible with other surgical tools. Proprietary Transcollation technology provides hemostatic sealing while the malleable shaft can be configured to fit the needs of a specific procedure.
Product Features and Benefits
- Malleable shaft can be shaped to reach challenging anatomical areas
- Built-in light provides illumination to aid in visualization of the surgical site
- Large bipolar electrode configuration provides hemostatic sealing across broad planes of tissue
Clinical Benefits
Transcollation technology provides the following clinical benefits when used during spinal surgery:
- Decreases blood loss per level fused1
- May help improve visibility in the surgical field2,3
- Decreases surgical time3
Surgical Applications
The MBS is commonly used in the following procedures:
- Multilevel Posterior Instrumented Fusions or Multilevel PLIF and TLIF, Scoliosis
- ALIF
For more information about the MBS, contact Medtronic Advanced Energy or your local sales representative.
Product Specifications:
| Electrode length | Electrode diameter | Center to center spacing between electrodes | Angle at tip | Out of body shaft length |
|---|---|---|---|---|
| 5.740mm (.226”) | 3.480mm (.137”) | 6.0mm (.236”) | 30 degrees | 129.54mm (5.1”) |
Ordering Information:
| Description | Catalog Number |
|---|---|
| Aquamantys Malleable Bipolar Sealer with Light | 23-301-1 |
References
- Mankin KP, Moore CA, Miller LE et al. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis. J Spinal Disorders & Techniques, October 2011; doi:10.1097/BSD.0b013e3182334ec5.
- Santiago P. Controlling epidural bleeding and improving visibility during spinal surgery with a novel bipolar sealing technology: a case report. Company funded, non-peer-reviewed Medtronic white paper, 2009.
- Snyder BD, Hedequist D, Shannon E. Bipolar sealing technology to control bleeding in pediatric spine surgery: a retrospective study. Poster presentation at Pediatric Orthopaedic Society of North America Annual Meeting 2007; Hollywood, FL.