Cardioblate® Gemini® Surgical Ablation Device
Indications: The Cardioblate Gemini Surgical Ablation Device is intended to ablate cardiac tissue during cardiac surgery using radiofrequency energy. The system is indicated for use under direct or endoscopic visualization, in surgical procedures, including minimally invasive surgical procedures.
Contraindications: The Cardioblate Gemini Surgical Ablation Device should not be used for:
- Patients that have active endocarditis at the time of surgery
- Ablation in a pool of blood (eg, through a purse string suture on a beating heart). Effects of this type of ablation are unknown.
Adverse Effects: Possible complications related to the ablation of cardiac tissue in combination with open heart surgery are tissue perforation, extension of extracorporeal bypass, perioperative heart rhythm disturbances (atrial and/or ventricular), postoperative embolic complications, pericardial effusion or tamponade, injury to the great vessels, valve leaflet damage, conduction disturbances (SA/AV node), acute ischemic myocardial event, thombus formation, nerve damage, unintentional burns, pericarditis, pleural effusion.
Cardioblate® Navigator® Tissue Dissector
Indications: The Cardioblate® Navigator™ Tissue Dissection Device is intended to dissect soft tissue during general, ENT, thoracic, urological, and gynecological surgical procedures. The device's battery-powered light source is used to navigate soft tissue for identification of the tip location around anatomic structures.
Potential Complications: Using excessive force when articulating may damage the distal links and/or cause unintended tissue damage.
Cardioblate Detect Surgical Pacing and Mapping Tool
Indications: The Cardioblate Detect Surgical Pacing and Mapping Tool is intended to ablate cardiac tissue during cardiac surgery using radiofrequency energy.
Contraindications: The Cardioblate Detect Surgical Pacing and Mapping Tool should not be used for:
- Patients that have active endocarditis at the time of surgery
Potential Complications: Possible complications related to the ablation of cardiac tissue in combination with open heart surgery are:
- Tissue perforation
- Extension of Extracorporeal bypass
- Perioperative heart rhythm disturbances (atrial and/or ventricular)
- Postoperative embolic complications
- Pericardial effusion or tamponade
- Injury to the great vessels
- Valve leaflet damage
- Conductions disturbances (SA/AV node)
- Acute ischemic myocardial event