Medtronic EnPulse® DR Series Specifications

Pacing Therapies and Parameters
Automatic Pacing and Sensing Management
Therapies to Promote Intrinsic Activation
Atrial Tachyarrhythmia Therapies and Interventions
Additional Features

Pacing Therapies and Parameters


Modes and Rates
Pacing Modes     DDDR, DDD, DDIR, DDI, DVIR, DVI, DOOR, DOO, VDD, VVIR, VDIR, VVI, VDI, VVT, VOOR, VOO, AAIR, ADIR, AAI, ADI, AAT, AOOR, AOO, ODO, OVO, OAO
Lower Rate   30, 35, 40, ...60, ...175 ppm (exc. 65,85)
Upper Tracking Rate1   80, 90, 95, ...130, ...180, 190, 200, 210 ppm
Upper Sensor Rate   80, 90, 95, ...130, ...180 ppm
Pulse Amplitude(A and V)2   0.5, 0.75, 1.0, ...3.5...4, 4.5, 5, 5.5, 6V, 7.5V
Pulse Width (A and V)   0.12, 0.15, 0.21, 0.27, 0.34, 0.4, 0.46, 0.52, 0.64, 0.76, 1, 1.25, 1.5 ms
Atrial Sensitivity   0.18, 0.25, 0.35, 0.5, 0.7, 1, 1, 4, 2, 2.8, 4mV
Ventricular Sensitivity   1, 1.4, 2, 2.8, 4, 5.6, 8, 11.2 mV
Pacing Polarity (A and V)   Bipolar, Unipolar, Configure
Sensing Polarity (A and V)   Bipolar, Unipolar, Configure

Rate Response
ADL Rate     60, 65, 70, ...95...120, 125, 130, 135, ...180 ppm
Rate Profile Optimization     ON, OFF
ADL Response     1-Inactive, 2-Less Active, 3-Mod. Active, 4-More Active, 5-Very Active
Exertion Response     1-Infrequent, 2-Less Frequent, 3-Mod. Frequent, 4-More Frequent, 5-Very Frequent
Activity Threshold     Low, Medium Low, Medium High, High
Acceleration     15 s, 30 s, 60 s
Deceleration     2.5 min, 5 min, 10 min Exercise
RAAV     ON, OFF
Start Rate     50, 55, 60, ...80...175 min
Stop Rate     55, 60, 65, ...120...180 min
Maximum Offset     -10, -20, -30, ...-40...-300 ms

Rate Drop Response
Detection Type     Low Rate, Drop, Both, OFF
Intervention Rate     60, 70, 75, 80, ...100...115, 120, 125, 130, 135, ...180 ppm (exc. 65, 85)
Intervention Duration     1, 2, 3, ...15 min
Detection Beats     1, 2, 3, beats
Drop Rate     30, 40, 50, ...100 ppm
Drop Size     10, 15, 20, ...25...50 ppm
Detection Window     0, 15, 20, 25, 30 s; 1, 1.5, 2, 2.5 min

Refractory/Blanking
PVARP     Auto, Varied, 150, 160, 170, ...500 ms
Minimum PVARP     150, 160, 170, ...250...500 ms
PVAB     130, 140, 150, ...180...350 ms
Atrial Refractory Period3     150, 160, 170, ...250...500 ms
Atrial Blanking3     130, 140, 150, ...180...350 ms
Atrial Blanking Period4     50-100 ms
Ventricular Refractory Period     150, 160, 170, ...230...500 ms
Ventricular Blanking Period5     50-100 ms
Ventricular Blanking (after atrial pace)(PAVB)     20, 28, 36, 44 ms

Automatic Pacing and Sensing Management


Atrial Capture Management™
Atrial Capture Management     OFF, Monitor Only, Adaptive
Amplitude Margin     1.5x, 2x, 2.5x, 3x, 4x (times)
Minimum Adapted Amplitude     0.5, 0.75, ...1.5...3.5 V
Capture Test Frequency     , 2, 4, 8, 12 hours; Day at rest; Day at...; 7 Days at...
Capture Test Time     12:00 AM, 1:00 AM, ...11:00 PM
Acute Phase Days Remaining     OFF, 7, 14, 21, ...84, 112, 140, 168, ...252 days

Ventricular Capture Management
Ventricular Capture Management     OFF, Monitor Only, Adaptive
Amplitude Margin     1.5x, 2x, 2.5x, 3x, 4x (times)
Minimum Adapted Amplitude     0.5, 0.75, ...2.5...3.5 V
Capture Test Frequency     15, 30 min; 1, 2, 4, 8, 12 hours; Day at rest; Day at...; 7 Days at...
Capture Test Time     12:00 AM, 1:00 AM, ...11:00 PM
Acute Phase Days Remaining     OFF, 7, 14, 21, ...84, 112, 140, 168, ...252 days
V. Sensing During Search     Unipolar, Bipolar, Adaptive
Sensing Assurance (A and V)     ON, OFF
Implant Detection     ON/Restart, OFF/Complete
Lead Monitor (A and V)     Configure, Monitor Only, Adaptive
   Notify if <     200 Ω
    Notify if >     1000, 2000, 3000, 4000 Ω
   Monitor Sensitivity     2, 3, 4, ...8...16

Therapies to Promote Intrinsic Activation


Intrinsic Activation and AV Intervals
Paced AV (PAV)     30, 40, 50, ...150...350 ms
Sensed AV (SAV)     30, 40, 50, ...120...350 ms
Search AV™+     ON, OFF
Max Increase to AV     10, 20, 30, ...170...250 ms
Sinus Preference™     ON, OFF
Sinus Preference Zone     3, 5, 10, 15, 20 ppm
Search Interval     5, 10, 20, 30 min
Sleep     ON, OFF
   Sleep Rate     30, 35, 40, ...50 ...90 ppm (exc. 65, 85)
   Bed Time     12:00 AM, 12:15 AM, 12:30 AM, ...10:00 PM...11:45 PM
   Wake Time     12:00 AM, 12:15 AM, 12:30 AM, ...8:00 AM...11:45 PM
Single Chamber Hysteresis     OFF, 40, 50, 60 ppm

Atrial Tachyarrhythmia Therapies and Interventions

Mode Switch (DDDR, DDD, VDD)     ON, OFF
Detect Rate     120, 125, ...175...200, 210, 220 ppm
Detect Duration     No Delay, 10, 20, ...60 sec
Blanked Flutter Search     ON, OFF

Interventions
Ventricular Response Pacing
(Regularize V-V During AT/AF
    ON, OFF
   Maximum Rate     80, 85, 90, ...110...130 ppm
Non-Competitive Atrial Pacing     ON, OFF

Additional Features

PMT Intervention     ON, OFF
PVC Response     ON, OFF
Ventricular Safety Pacing     ON, OFF


References
  1. If the Upper Tracking Rate is set to 190 min-1 or higher, the atrial and ventricular Rate Limit is 227 min-1 (+ 17 min-1). Otherwise, the atrial and ventricular Rate Limit is 200 min-1 (+ 20 min-1).
  2. Tolerance for amplitudes from 0.5 V through 6.0 V is + 10%, and for 7.5 V is -20/+0%. Tolerances are based on 37C and 500Ω load. Amplitude is dermined 200 µs after the leading edge of the pace.
  3. Atrial modes only.
  4. Blanking for Paced AV (PAV) and Sensed AV (SAV) intervals; pacemaker-determined.
  5. Blanking for Ventricular Refractory Period; pacemaker-determined.

    For additional information, please refer to the technical manual.