Medtronic
 
 

Heart Failure

InSync II Marquis™ CRT-D Device

The Medtronic InSync II Marquis™ cardiac resynchronization and ICD device offers patient-tailored CRT options and effective ICD protection in conjunction with powerful heart failure management and patient safety features.

Key Features

Fast, Effective ICD Therapy Combined with Patient-Tailored Cardiac Resynchronization Therapy

  • 30 Joules high energy output in 5.9 to 7.5 seconds throughout the life of the device.
  • Painless antitachycardia pacing (ATP) therapy to terminate 3 out of 4 episodes of fast ventricular tachycardia (VT).1
  • Enhanced PR Logic dual-chamber detection to maintain high sensitivity for ventricular tachyarrhythmias while improving discrimination for supraventricular tachycardias. Offers 95.2% accuracy (Positive Predictive Value) in delivered therapies.2
  • Separately programmable ventricular outputs for adapting pacing outputs to unique patient needs.
  • Special pacing functions to manage heart failure patients who also experience atrial fibrillation.
  • Programmable with the Medtronic CareLink® Programmer

Powerful Heart Failure Management and Advanced Patient Alert Capabilities

  • Heart Failure Management Report showing 14-month trends of key heart failure patient monitoring categories such as AT/AF Burden, ventricular rate during AF, heart rate variability, patient activity and night/day heart rates. Observation highlight heart failure related parameters outside of typical ranges.
  • Cardiac Compass® Report with additional information about ventricular arrhythmia detection and therapies.
  • Rate Histogram Report provides information about % pacing during episodes of AF, sinus rate profiles and ventricular rate profile during AF.
  • Remote device follow-up with the Medtronic CareLink Network can dramatically reduce the time and resources required for routine device checks. Patients can use the Medtronic CareLink Service to transmit comprehensive device data using a standard phone line while at home, work or while traveling. Within minutes, clinics can view patient device data from any Internet-enabled PC using the secure clinician website. Learn more.
  • Advanced patient alert capabilities, including lead integrity, battery condition change, and ICD therapy issues.

Mechanical Specifications

Volume     38 cc
Size: H x W x D   73 x 51 x 14 mm
Mass   77 g
Pace/sense ports   Three IS-1 bipolar (A, RV, LV)
Defibrillation ports   Two DF-1 (RV coil [HVB], SVC [HVX])
External shield   Titanium
Radiopaque ID   PRJ
Battery   Lithium silver vanadium oxide; 3.2 V nominal

Medtronic CareLink® Network
Remote device follow-up with the Medtronic CareLink Network can dramatically reduce the time and resources required for routine device checks. Patients can use the Medtronic CareLink Service to transmit comprehensive device data using a standard phone line while at home, work or while traveling. Within minutes, clinics can view patient device data from any Internet-enabled PC using the secure clinician website. Learn more.

References
  1. Wathen MS, Sweeney MO, DeGroot PJ, et al. Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation. August 14, 2001;104:796-801.
  2. Accuracy based on Positive Predictive Value (PPV). Wilkoff B, Gillberg J, DeSouza C. The Enhanced PR Logic dual chamber tachyarrhythmia detection algorithm: retrospective analysis of supraventricular tachycardia with long PR intervals. JACC Abstract #$873-4, Feb. 2001.

Additional Information