InSync Marquis™ CRT-D Device
The Medtronic InSync Marquis™ offers powerful ICD and cardiac resynchronization therapy along with the tools for more efficient heart failure patient management.
Key Features
Powerful ICD and Cardiac Resynchronization Therapy
- 30 Joules, high energy output in 5.9 to 7.5 seconds throughout the life of the device.
- Painless antitachycardia pacing (ATP) therapy to terminate 3 out of 4 episodes of fast ventricular tachycardia (VT).1
- Enhanced PR Logic dual-chamber detection to maintain high sensitivity for ventricular tachyarrhythmias while improving discrimination for supraventricular tachycardias. Offers 95.2% accuracy (Positive Predictive Value) in delivered therapies.2
- Programmable with the Medtronic CareLink® Programmer.
Advanced Monitoring for Changing Patient Conditions
- Medtronic's exclusive Cardiac Compass® Report with additional information about ventricular arrhythmia detection and therapies.
- Advanced patient alert capabilities, including lead integrity, battery condition change, and ICD therapy issues.
- Fast telemetry speed-up to 20x improvement-with RapidRead™ telemetry.
- Perform tests and record ECGs without attaching separate ECG leads with Leadless™ ECG.
- Remote device follow-up with the Medtronic CareLink Network can dramatically reduce the time and resources required for routine device checks. Patients can use the Medtronic CareLink Service to transmit comprehensive device data using a standard phone line while at home, work or while traveling. Within minutes, clinics can view patient device data from any Internet-enabled PC using the secure clinician website. Learn more.
Mechanical Specifications
| Volume |
|
38 cc |
| Size: H x W x D |
|
73 x 51 x 14 mm |
| Mass |
|
77 g |
| Pace/sense ports |
|
Three IS-1 bipolar (A, RV, LV) |
| Defibrillation ports |
|
Two DF-1 (RV coil [HVB], SVC [HVX]) |
| External shield |
|
Titanium |
| Radiopaque ID |
|
PLT |
| Battery |
|
Lithium silver vanadium oxide; 3.2 V nominal |
Medtronic CareLink® Network
Remote device follow-up with the Medtronic CareLink Network can dramatically reduce the time and resources required for routine device checks. Patients can use the Medtronic CareLink Service to transmit comprehensive device data using a standard phone line while at home, work or while traveling. Within minutes, clinics can view patient device data from any Internet-enabled PC using the secure clinician website. Learn more.
References
- Wathen MS, Sweeney MO, DeGroot PJ, et al. Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation. August 14, 2001;104:796-801.
- Accuracy based on Positive Predictive Value (PPV). Wilkoff B, Gillberg J, DeSouza C. The Enhanced PR Logic dual chamber tachyarrhythmia detection algorithm: retrospective analysis of supraventricular tachycardia with long PR intervals. JACC Abstract #$873-4, Feb. 2001.
|