Medtronic
 
 

Tachyarrhythmia
Management

GEM® III AT

Dual Chamber ICD for Total Arrhythmia Management

GEM III AT
GEM III AT
Model 7276

A total system for managing patients with both ventricular and atrial arrhythmias.

AT™ Trio offers a suite of atrial arrhythmia management tools:

  • AT™ Monitoring provides detailed diagnostic information to guide atrial arrhythmia therapy regimens
  • AT™ Intervention provides proactive and responsive pacing therapies designed to intervene when potentially proarrhythmic events are detected
  • AT™ Termination treats atrial tachyarrhythmia episodes with custom therapy regimens to restore sinus rhythm
Clinically proven atrial therapy:
  • Antitachycardia Pacing Therapy (ATP) successfully terminated 55% of atrial tachyarrhythmia episodes1
  • AT™ Intervention and AT™ Termination therapies reduced mean atrial tachyarrhythmia burden by 89%1
AT™ Termination therapies for atrial tachyarrhythmias:
  • Customized, tiered approach with Ramp, Burst+, and/or 50 Hz Burst ATP
  • Cardioversion for symptomatic patients can be physician or patient controlled or programmed for timed automatic delivery
Ambulatory patient management with the handheld InCheck™ AT Patient Assistant:
  • Allows patients to query atrial arrhythmia status anytime, anywhere
  • Allows symptomatic patients to perform out-of-hospital cardioversion

Clinically proven to reduce inappropriate therapies:

  • PR Logic™ is designed to maintain high sensitivity for ventricular tachyarrhythmias while increasing specificity for atrial arrhythmias and resulting in fewer unnecessary shocks for patients

Improved device longevity2

Medtronic Vision™ software and Quick Look™ home page simplify programming and follow-up

Ventricular Tachyarrhythmia Therapies:

  • Antitachycardia pacing (ATP)
  • Cardioversion
  • Defibrillation

Dual chamber rate responsive pacing therapy

Common software and programmer for all Medtronic ICDs and pacemakers

Flexible lead choices for specific physician preferences

Delivered output for AT/AF cardioversion and VT/VF cardioversion or defibrillation: 0.4 — 30 J within 7 seconds charge time

Size: 39.5 cc, 78 g

Medtronic CareLink® Network

  • The industry’s first Internet-based remote monitoring service that is comparable to an in-office device check
  • Connects Gem III patients who are at home or traveling with physicians for “virtual office visits”
  • Physicians can access device data anytime, from any Web-capable PC
  • Provides comprehensive device data in approximately one-third the time of a typical office visit
References
  1. Medtronic Jewel™ AF ICD clinical data on file.
  2. 6.2 years using 15% DDD pacing, quarterly charges, 900 Ohm impedance, 2V pacing output, 0.6 ms pacing pulse width.