Tachyarrhythmia
Management |
|
|
|
Marquis® Family of ICDs
Convenience, Performance and Safety

Marquis DR
Model 7274
Convenience
- Leadless™ ECG enables you to approximate a
surface ECG, and record cardiac activity and perform tests without
attaching separate ECG leads
- RapidRead™ telemetry offers up to a 20x improvement
in telemetry speed 1
- Automatic daily P- and R-wave amplitudes and pacing/painless
HV lead impedance measurements. Measurements trended for over 80
weeks for long term lead impedance measurement 2
- One page Cardiac
Compass® report graphically displays your patient’s
clinical progress for up to 14 months
- Leading Internet-based technology for remote patient follow-up, the
Medtronic CareLink® Network , empowers you
to improve clinic operations and enhance patient care.
Performance:
Marquis VR
Model 7230
- Battery technology delivers short, consistent charge
times to full output (30J delivered)
- Ensure the greatest safety margin with the shortest time to
therapy
- 5.9 seconds at BOL to 7.5 seconds (7.7 seconds for VR) at ERIa
- A reduction of the charging time may help to prevent pre-shock
syncopies 3,4
- Cost-effective therapy:
- Marquis DR longevity of 8 years at 50% pacing with biannual
charges 5
- Marquis VR longevity of 10 years at 50% pacing with biannual
charg
Safety:
Identify system issues before they become clinical problems
- Expanded Patient Alert™ – exclusive to
Medtronic – provides 6 new indicators to alert the patient
when follow-up care is needed
- More than 90% of alert tones identify clinically significant
patient safety issues that require physician intervention6
- Fewer inappropriate therapies: Enhanced PR Logic™ dual
chamber detection delivers up to 95.2% accuracy (Positive Predictive
Value, or PPV) in delivered therapies7
- High-resolution detection: New Wavelet™ Dynamic Discrimination
criterion - exclusive to Marquis VR - compares the morphology
of the arrhythmia to a sinus rhythm template for more accurate
classification
- Template of QRS complex is updated by the Auto Template feature
when sinus rhythm changes
- Easy to program
Medtronic CareLink® Network
- The industry’s first Internet-based remote monitoring service that is comparable to an in-office device check
- Connects Marquis patients who are at home or traveling with physicians for “virtual office visits”
- Physicians can access device data anytime, from any Web-capable PC
- Provides comprehensive device data in approximately one-third the time of a typical office visit
References
- Compared to Medtronic GEM® III DR Model 7275 ICD.
- DR has P- and R-wave. Marquis VR has only R-wave.
- Himmrich E, Przibille O, Liebrich D, Zellerhoff C, Rosocha S. Pre-shock
syncopy in patients with implanted defibrillators - incidence and
reasons. Cardiostim Abstract #1180 (122/5), 2000.
- Gradaus R, Bode-Schnurbus L, Weber M, et al. Effect of ventricular
fibrillation duration on the defibrillation threshold in humans, PACE.
2002;25:14-19.
- Pacing parameters: 60 ppm, 2.5 V, 0.4 ms, 900
;
charges are 30J maximum energy shocks or capacitor reformations.
- Iowa Heart Center (Des Moines, Iowa, USA) single-center study of
215 GEM®Family ICDs with Patient Alert™ programmed
ON. Data on file.
- Wilkoff BL, Gillberg JM, DeSouza CM. The Enhanced PR Logic dual
chamber tachyarrhythmia detection algorithm: retrospective analysis
of supraventricular tachycardia with long PR intervals. JACC Abstract
#873-4, Feb. 2001.
Notes
aA charge is a maximum-energy shock or capacitor reformation.
|
|
“We view remote telemetry, such as that provided by the CareLink
Network, as the new standard of care for ICD patients.
I expect the technology to increasingly change the way patients
with implantable devices are cared for across the country.”
W. Ben Johnson, M.D., an electrophysiologist
at the Des Moines-based Iowa Heart Center.
The Medtronic CareLink Network is transforming patient care
with the first and only remote monitoring service for device
patients and their clinics.
Learn
more » |
|