Medtronic
 
 

Tachyarrhythmia
Management

Marquis® Family of ICDs

Convenience, Performance and Safety

Marquis DR
Marquis DR
Model 7274

Convenience

  • Leadless™ ECG enables you to approximate a surface ECG, and record cardiac activity and perform tests without attaching separate ECG leads
  • RapidRead™ telemetry offers up to a 20x improvement in telemetry speed 1
  • Automatic daily P- and R-wave amplitudes and pacing/painless HV lead impedance measurements. Measurements trended for over 80 weeks for long term lead impedance measurement 2
  • One page Cardiac Compass® report graphically displays your patient’s clinical progress for up to 14 months
  • Leading Internet-based technology for remote patient follow-up, the Medtronic CareLink® Network , empowers you to improve clinic operations and enhance patient care.

Performance:

Marquis VR
Marquis VR
Model 7230
  • Battery technology delivers short, consistent charge times to full output (30J delivered)
    • Ensure the greatest safety margin with the shortest time to therapy
    • 5.9 seconds at BOL to 7.5 seconds (7.7 seconds for VR) at ERIa
  • A reduction of the charging time may help to prevent pre-shock syncopies 3,4
  • Cost-effective therapy:
    • Marquis DR longevity of 8 years at 50% pacing with biannual charges 5
    • Marquis VR longevity of 10 years at 50% pacing with biannual charg

Safety:

Identify system issues before they become clinical problems
  • Expanded Patient Alert™ – exclusive to Medtronic – provides 6 new indicators to alert the patient when follow-up care is needed
    • More than 90% of alert tones identify clinically significant patient safety issues that require physician intervention6
  • Fewer inappropriate therapies: Enhanced PR Logic™  dual chamber detection delivers up to 95.2% accuracy (Positive Predictive Value, or PPV) in delivered therapies7
  • High-resolution detection: New Wavelet™ Dynamic Discrimination criterion - exclusive to Marquis VR - compares the morphology of the arrhythmia to a sinus rhythm template for more accurate classification
    • Template of QRS complex is updated by the Auto Template feature when sinus rhythm changes
    • Easy to program

Medtronic CareLink® Network

  • The industry’s first Internet-based remote monitoring service that is comparable to an in-office device check
  • Connects Marquis patients who are at home or traveling with physicians for “virtual office visits”
  • Physicians can access device data anytime, from any Web-capable PC
  • Provides comprehensive device data in approximately one-third the time of a typical office visit
References
  1. Compared to Medtronic GEM® III DR Model 7275 ICD.
  2. DR has P- and R-wave. Marquis VR has only R-wave.
  3. Himmrich E, Przibille O, Liebrich D, Zellerhoff C, Rosocha S. Pre-shock syncopy in patients with implanted defibrillators - incidence and reasons. Cardiostim Abstract #1180 (122/5), 2000.
  4. Gradaus R, Bode-Schnurbus L, Weber M, et al. Effect of ventricular fibrillation duration on the defibrillation threshold in humans, PACE. 2002;25:14-19.
  5. Pacing parameters: 60 ppm, 2.5 V, 0.4 ms, 900ohm; charges are 30J maximum energy shocks or capacitor reformations.
  6. Iowa Heart Center (Des Moines, Iowa, USA) single-center study of 215 GEM®Family ICDs with Patient Alert™ programmed ON. Data on file.
  7. Wilkoff BL, Gillberg JM, DeSouza CM. The Enhanced PR Logic dual chamber tachyarrhythmia detection algorithm: retrospective analysis of supraventricular tachycardia with long PR intervals. JACC Abstract #873-4, Feb. 2001.

Notes
aA charge is a maximum-energy shock or capacitor reformation.

Additional Information

  • Request information
    PainFREE™ Therapy
    clinical results and programming tips
  • Cardiac Compass™ simplifies patient management. Request Case Study and Technical Tip Cards
  • Medtronic Connect
    Visit Medtronic Connect
    for the latest in online presentation tools and in-depth information.
Remote Monitoring Now Available

“We view remote telemetry, such as that provided by the CareLink Network, as the new standard of care for ICD patients. I expect the technology to increasingly change the way patients with implantable devices are cared for across the country.”

W. Ben Johnson, M.D., an electrophysiologist at the Des Moines-based Iowa Heart Center.

The Medtronic CareLink Network is transforming patient care with the first and only remote monitoring service for device patients and their clinics.

Learn more »