Medtronic
 
 

Tachyarrhythmia
Management

Virtuoso™ ICDs

Virtuoso Dual Chamber ICD: [DR ICD]1
with Atrial Therapies and Diagnostics

  • 35 Joules, delivered
  • 8.2 seconds BOS*, 9.8 seconds RRT**
  • Longevity 6.9 years2
  • 37 cc, 68g
  • Size: H x W x Da - 64 x 51 x 15mm
  • Enhanced PR Logic® Dual Chamber Detection maintains high sensitivity for ventricular tachyarrhythmias while improving discrimination for supraventricular tachycardias. Offers 95.2% accuracy Positive Predictive Value (PPV) in delivered therapies.3
  • Enhanced PR Logic Dual Chamber Detection with modified Sinus Tach Rule rejects over one-third more SVTs compared to the original PR Logic with no user programming.***4
  • Programmable with the Medtronic CareLink® programmer.

Virtuoso Single Chamber ICD: [VR ICD]1

  • 35 Joules, delivered
  • 8.2 seconds BOS*, 10 seconds RRT**
  • Longevity 8.0 years5
  • 37 cc, 68g
  • Size: H x W x Da - 64 x 51 x 15mm
  • Wavelet Dynamic Discrimination Criterion is an electrogram morphology algorithm with simple on-off programming.
  • In the WAVE study, Wavelet Discrimination Criterion reduced inappropriate therapy by 78.2% based on 100% spontaneous arrhythmias.****6
  • Programmable with the Medtronic CareLink® programmer.
* Beginning of service
** Recommended replacement time.
*** GEM® DR
**** When episodes with rate and duration overrides are excluded.

References
  1. Grommets may protrude slightly beyond the can surface.
  1. Medtronic Virtuoso ICDs reference manual. Fully formed capacitors.
  2. 50% atrial and 5% ventricular pacing in MVP Mode at 60 ppm, 3 V, 0.4 ms, 500 ohms; pre-arrhythmia EGM storage on; 2 full energy charges per year. Programming pre-arrhythmia EGM to “off” increases longevity by 23% or 2.8 months per year.
  3. Accuracy based on Positive Predictive Value (PPV). Wilkoff B, Gillberg J, DeSouza C. The Enhanced PR Logic dual chamber tachyarrhythmia detection algorithm: retrospective analysis of supraventricular tachycardia with long PR intervals. JACC Abstract #873-4, Feb. 2001.
  4. Stadler, RW, An adaptive interval-based algorithm for withholding ICD therapy during sinus tachycardia, PACE May 2003; Vol. 26 1189-1201.
  5. 15% VVI at 60 ppm, 3 V, 0.4 ms, 500 ohms; pre-arrhythmia EGM storage on; 2 full energy charges per year. Programming pre-arrhythmia EGM to “off” increases longevity by 27% or 3.3 months per year.
  6. Klein GK, Manolis A,, Viskin S , et al. Clinical performance of Wavelet TM Dynamic VT/SVT Discrimination Algorithm in a worldwide single chamber ICD population. Circulation . Abstract #1650, Oct 2004; Vol. 110, No. 17.

 