Medtronic
 
 

Medtronic
Vision 3D™
Portfolio

Secura™ DR and VR ICDs with
Complete Capture Management™

Secura™ DR and VR ICDs
with Complete Capture Management™

The Right Therapy at the Right Time

The first and only completely automatic—wireless ICDs to combine industry-leading pacing and ICD exclusives.

Completely Automatic™

Automaticity with Complete Capture Management

  • Ensures pacing capture in all heart chambers (ACM, RVCM)1
  • Provides a daily complete device check—automatically:
    • Lead impedance
    • Battery status
    • All-chamber threshold evaluation
    • Sensing amplitudes
  • Eliminates need for manual threshold checks, freeing time for clinicians and patients
  • Therapies automatically adapt to changing patient needs

Timely, Efficient Remote Follow-Up

The same in-depth device information as an office visit

  • Identify and assess problems sooner with complete remote follow-up via the CareLink® Network
  • Receive physician-selected critical data automatically and wirelessly, without patient intervention, through CareAlert® Notifications

Flexibility Means Risk Reduction

Programmable options provide noninvasive solutions for some complex cases

  • Programmable RV Sensing may resolve T-wave oversensing and other sensing issues that may lead to inappropriate shocks
  • Avoid surgical intervention and enhance safety for patients via Programmable SVC Coil

Proven Solutions

Successful disease management options only from Medtronic

  • MVP®—Reduces unnecessary RV pacing by 99%*2
  • Wireless—Provides advantages in safety and efficiency with Conexus® Wireless Telemetry
  • OptiVol®—Monitors fluid status in patients with heart failure for timely clinical intervention
  • AT/AF Management—Offers unprecedented diagnostics and therapies including Cardiac Compass® trends, ATP, Conducted AF Response, and dual channel EGM
  • Superior Battery Technology—Ensures short, consistent charge times for the life of the device

Medtronic Pain Free™ Solutions—Proven Strategies to Reduce Shocks

Shocks save lives. Reducing unnecessary shocks improves them.

  • Only Medtronic ICDs are proven to eliminate three out of four shocks, thus improving patient quality of life3

     
  • ATP During Charging provides patients the double protection of receiving painless ATP, yet allows no delay to shock if needed1
     

Secura— DR

Secura— VR

  • 7.7 seconds BOS**
  • 9.2 seconds RRT***
  • 7.6 years longevity4
  • 37 cc, 68 g
  • 7.7 seconds BOS**
  • 9.4 seconds RRT***
  • 8.8 years longevity5
  • 37 cc, 68 g

*Median number
**Beginning of Service
***Recommended Replacement Time

References
  1. Medtronic Secura™ ICD System Reference Guide
  2. Gillis AM, Pürerfellner H, Israel CW, et al. Reduction of unnecessary ventricular pacing due to the Managed Ventricular Pacing (MVP) mode in pacemaker patients: Benefit for both sinus node disease (SND) and AV block (AVB) indications. Heart Rhythm. 2005;Abstract AB21-1.
  3. Wathen MS, DeGroot PJ, Sweeny MO, et al, for the PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. October 26, 2004;110(17):2591-2596.
  4. 50% atrial and 5% ventricular pacing in MVP Mode at 60 ppm, 2.5 V, 0.4 ms, 600 ohms; pre-arrhythmia EGM storage off; 2 full energy charges per year.
  5. 15% VVI at 60 ppm, 2.5 V, 0.4 ms, 600 ohms; pre-arrhythmia EGM storage off; 2 full energy charges per year.

Part of the Medtronic Vision 3D™ Portfolio