GEM®, GEM® II, & GEM®
III Family of ICDs
GEM® III DR
Enhanced tachyarrhythmia therapy, safety,
and convenience:
- Fewer unnecessary shocks for patients
- Greater device longevity (6.1 years using
15% pacing
and quarterly charges)
- Exclusive Patient Alert monitors system for five
safety conditions and alerts patients to seek follow-up
care if necessary
- Enhanced diagnostics make follow-up more efficient and
effective
- Medtronic Vision® software and Quick Look home
page simplify programming
and follow-up
Proven PR Logic analyzes rate, pattern, regularity and AV dissociation
to detect and classify arrhythmias and trigger device response:
- When tachyarrhythmia therapy is delivered, device has 95.2%
Positive Predictive Value with enhanced PR Logic
- When tachyarrhythmia therapy is withheld, device has 100%
sensitivity that it is not needed
|
|
|
 GEM
III DR
Model 7275
|

Available with
GEM
III DR/VR
“We
view remote telemetry, such as that provided by the CareLink Network,
as
the new standard of care for ICD patients.
I expect the technology
to increasingly change the way patients with implantable devices are
cared for across the country.”
 |
W. Ben Johnson, M.D., an electrophysiologist
at the Des Moines-based Iowa Heart
Center. |
The Medtronic
CareLink Network is transforming patient care with the first and only
remote monitoring
service for device patients and their clinics.
Learn
more > |
|
Ventricular Tachyarrhythmia Therapies:
- Antitachycardia pacing (ATP)
- Cardioversion
- Defibrillation
Dual chamber rate responsive pacing therapy
Common software and programmer
for all Medtronic ICDs and pacemakers
Flexible lead
choices for specific physician preferences
Delivered output: 0.4 — 30 J within 7 seconds charge time
Size: 39.5 cc, 78 g
Return to Top of the Page
|
GEM® III VR
Model 7231
Enhanced tachyarrhythmia therapy, safety,
and convenience: |
|
- Fewer unnecessary shocks for patients
- Greater device longevity (7.6 years using 15% pacing and quarterly
charges)
- Exclusive Patient Alert™ monitors system for five safety
conditions and alerts patients to seek follow-up care if necessary
- Enhanced diagnostics make follow-up more efficient and effective
- Medtronic Vision™ software and Quick Look™ home
page simplify programming and follow-up
EGM Width Criterion reduces inappropriate shock therapy by discriminating
SVTs from VTs:
- 95.2% Positive Predictive Value when VT and SR widths vary by at least
a 10-ms difference (EGM Width Clinical Study)
- 88% increase in detection specificity (EGM Width Clinical Study)
Ventricular Tachyarrhythmia Therapies:
- Antitachycardia pacing (ATP)
- Cardioversion
- Defibrillation
Single chamber rate responsive pacing therapy
Common software and programmer for
all Medtronic ICDs and pacemakers
Flexible lead choices
for specific physician preferences
Size: 39 cc, 77 g
|