Visia AF and Visia AF MRI

Implantable Cardioverter Defibrillators (ICDs) for Tachyarrhythmia Management

Single Chamber ICD + AF Diagnostics

Visia AF™ and Visia AF MRI™ are the only single chamber ICDs with a traditional lead that enable you to continuously monitor, diagnose, and manage atrial fibrillation (AF) patients. Ensure your patients get 1.5T and 3T MRI access with Visia AF MRI, when MR conditions for use are met.

The Need for AF Diagnostics in Single Chamber ICDs

  • 20% of single chamber ICD patients may also develop new onset AF within the first two years post-implant1
  • AF increases the risk of stroke by up to 5x2
  • AF increases the risk of heart failure by 3x3
  • 79-94% of AF episodes are asymptomatic4-9
  • 68% of AT/AF episodes are missed with annual Holter monitoring9

Novel AF Detection

Atrial Fibrillation can conduct into the ventricle resulting in a variable heart rate, which can lead to variability in the timing of the R waves. Visia AF and Visia AF MRI monitor R-R variability and look for patterns, then determine if the variability and pattern are sufficient to meet the classification of AF.

Click to learn more about this novel AF detection algorithm and how it works. 


CLINICALLY PROVEN

Based on clinically proven AF detection,10 Visia AF and Visia AF MRI have high AF burden and episode sensitivity.

Visia AF and Visia AF MRI burden and sensitivity data.

Complete Diagnostics + CareAlert® Notifications

Visia AF and Visia AF MRI provide valuable information to aid decision making. Evaluate AF episodes and burden with programmable alerts to help manage AF patients.

Example of CareAlert Notifications from Visia AF and Visia AF MRI

Model Specifications

Device Model Number Asset

Visia AF Single Chamber
DF4 ICD 

DVAB1D4 

Download Spec Sheet

Visia AF Single Chamber
DF-1 ICD

DVAB1D1 

Download Spec Sheet

Visia AF MRI S
Single Chamber
DF4 ICD

DVFC3D4 

Download Spec Sheet

Visia AF MRI S
Single Chamber
DF-1 ICD

DVFC3D1 

Download Spec Sheet

Visia AF MRI
Single Chamber
DF4 ICD

DVFB1D4

Download Spec Sheet

Visia AF MRI
Single Chamber
DF-1 ICD

DVFB1D1

Download Spec Sheet

Industry-Leading Projected Longevity & Warranty

Projected Longevity*1111 years

Warranty10 years


*

Projected Life is based on VVI for VR from the manuals of the Visia AF ICD System.11
The Visia AF MRI  and Visia AF models share the same battery, telemetry, and programming features that impact longevity. 

Limited lifetime warranty, some restrictions may apply. The limited lifetime warranty applies to the performance of the device and includes some reimbursement to patients of unreimbursed medical expenses. The warranty is limited to the provisions in the written Limited Warranty document that accompanies each product. Consult the written limited warranty document for details, a copy of which will be provided upon request. 


1

Schloss EJ, et al. How Common is New Onset Atrial Fibrillation in Single Chamber ICD Patients? Sub-analysis from the PainFree SST Study. Presented at AHA 2015 (Abstract 17946).

2

Wolf PA, et al. Stroke. 1991;22:983-988.

3

Stewart S, et al. Am J Med. 2002;113:359-364.

4

Strickberger SA, et al. Heart Rhythm. 2005;2:125-131.

5

Varma A, et al. JAMA Intern Med. 2013;173:149-156.

6

Orlov MV, et al. Pacing Clin Electrophysiol. 2007;30:404-411.

7

Quirino G, et al. Pacing Clin Electrophysiol. 2009;32:91-98.

8

Page RL, et al. Circulation. 1994;89:224-227.

9

Ziegler PD, et al. Heart Rhythm. 2006;3:1445-1452.

10

Deshmukh A, et al. Pacing Clin Electrophysiol. 2016;39:1031-1037.