This site uses cookies to store information on your computer. Some are essential to make our site work; others help us improve the user experience. By using the site, you consent to the placement of these cookies. You may at any time change the settings regarding cookies. Read our privacy statement to learn more.
Palindrome™ Precision Symmetric Tip Dialysis Catheters
The Palindrome™ Precision symmetric tip dialysis catheter has a unique symmetric tip and laser-cut side slots that minimize recirculation and the likelihood of positional occlusion, as well as reduce clot formation by decreasing debris attachment.
Order Code | Description | Arterial Priming Volume (mL) | Venous Priming Volume (mL) | Unit of Measure | Quantity |
---|---|---|---|---|---|
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit | |||||
8888145014P |
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 19 cm, Overall Length 36 cm |
1.6 |
1.6 | Carton | 5 |
8888145015P |
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 23 cm, Overall Length 40 cm |
1.9 | 1.9 | Carton | 5 |
8888145016P |
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 28 cm, Overall Length 45 cm |
2.1 |
2.1 | Carton | 5 |
8888145017P |
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 33 cm, Overall Length 50 cm |
2.3 |
2.3 | Carton | 5 |
8888146044P |
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 44 cm, Overall Length 61 cm |
2.6 |
2.6 |
Carton |
5 |
8888145018P |
Palindrome™ Precision Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 55 cm, Overall Length 72 cm |
3.1 |
3.1 | Carton | 5 |
Palindrome™ Symmetric Tip Dual Lumen Catheter Kits | |||||
With Tal VenaTrac™ Insertion Stylets | |||||
8888145039P |
Palindrome™ Precision with Tal VenaTracTM Insertion Stylets, Insertion Length 19 cm, Overall Length 36 cm |
1.6 |
1.6 |
Carton |
5 |
8888145040P |
Palindrome™ Precision with Tal VenaTracTM Insertion Stylets, Insertion Length 23 cm, Overall Length 40 cm |
1.9 |
1.9 |
Carton |
5 |
8888145041P |
Palindrome™ Precision with Tal VenaTracTM Insertion Stylets, Insertion Length 28 cm, Overall Length 45 cm |
2.1 |
2.1 |
Carton |
5 |
8888145042P |
Palindrome™ Precision with Tal VenaTracTM Insertion Stylets, Insertion Length 33 cm, Overall Length 50 cm |
2.3 |
2.3 |
Carton |
5 |
Standard Tip | |||||
8888145014 |
Palindrome™ Symmetric Tip Dual Lumen Catheter Kit, Insertion length 19 cm, Overall length 36 cm |
1.6 |
1.6 | Carton | 5 |
8888145015 |
Palindrome™ Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 23 cm, Overall Length 40 cm |
1.9 |
1.9 | Carton | 5 |
8888145016 |
Palindrome™ Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 28 cm, Overall Length 45 cm |
2.1 |
2.1 | Carton | 5 |
8888145017 |
Palindrome™ Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 33 cm, Overall Length 50 cm |
2.3 |
2.3 | Carton | 5 |
8888145018 | Palindrome™ Symmetric Tip Dual Lumen Catheter Kit, Insertion Length 55 cm, Overall Length 72 cm | 3.1 | 3.1 | Carton | 5 |
Palindrome™ Precision H–Heparin Coated Dialysis Catheter
Order Code | Description | Arterial Priming Volume (mL) | Venous Priming Volume (mL) | Unit of Measure | Quantity |
---|---|---|---|---|---|
Palindrome™ Precision H–Heparin Coating | |||||
Precision Tip for Europe | |||||
8888145043CP | Palindrome™ Precision H-Heparin Coating, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | 5 |
8888145044CP | Palindrome™ Precision H-Heparin Coating, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | 5 |
8888145045CP | Palindrome™ Precision H-Heparin Coating, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | 5 |
8888145046CP | Palindrome™ Precision H-Heparin Coating, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | 5 |
Precision Tip outside Europe | |||||
8888145043P | Palindrome™ Precision H-Heparin Coating, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | 5 |
8888145044P | Palindrome™ Precision H-Heparin Coating, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | 5 |
8888145045CP | Palindrome™ Precision H-Heparin Coating, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | 5 |
8888145046P | Palindrome™ Precision H-Heparin Coating, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | 5 |
Standard Tip for Europe | |||||
8888145044C | Palindrome™ H–Heparin Coating, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | |
8888145045C | Palindrome™ H–Heparin Coating, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | |
8888145046C | Palindrome™ H–Heparin Coating, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | |
Standard Tip Outside Europe | |||||
8888145043 | Palindrome™ H–Heparin Coating, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | |
8888145044 | Palindrome™ H–Heparin Coating, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | |
8888145045 | Palindrome™ H–Heparin Coating, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | |
8888145046 | Palindrome™ H–Heparin Coating, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton |
Palindrome™ Precision SI–Silver Ion Antimicrobial Dialysis Catheter
The Palindrome™ Precision SI–Silver Ion antimicrobial dialysis catheter reduces microbial colonization on the catheter surface with a silver ion sleeve.
Order Code | Description | Arterial Priming Volume (mL) |
Venous Priming Volume (mL) |
Unit of Measure |
Quantity |
---|---|---|---|---|---|
Palindrome™ Precision Tip SI–Silver Ion Antimicrobial Dialysis Catheter Kits | |||||
8888145062P | Palindrome™ Precision SI-Silver Ion Antimicrobial Sleeve, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | 5 |
8888145063P | Palindrome™ Precision SI-Silver Ion Antimicrobial Sleeve, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | 5 |
8888145064P | Palindrome™ Precision SI-Silver Ion Antimicrobial Sleeve, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | 5 |
8888145065P | Palindrome™ Precision SI-Silver Ion Antimicrobial Sleeve, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | 5 |
8888145066P* | Palindrome™ Precision SI-Silver Ion Antimicrobial Sleeve, Insertion Length 55 cm, Overall Length 72 cm | 3.1 | 3.1 | Carton | 5 |
Palindrome™ SI–Silver Ion Antimicrobial Dialysis Catheter Kits | |||||
8888145062 | Palindrome™ SI–Silver Ion Antimicrobial Sleeve, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | 5 |
8888145063 | Palindrome™ SI–Silver Ion Antimicrobial Sleeve, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | 5 |
8888145064 | Palindrome™ SI–Silver Ion Antimicrobial Sleeve, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | 5 |
8888145065 | Palindrome™ SI–Silver Ion Antimicrobial Sleeve, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | 5 |
8888145066* | Palindrome™ SI–Silver Ion Antimicrobial Sleeve, Insertion Length 55 cm, Overall Length 72 cm | 3.1 | 3.1 | Carton | 5 |
*Does not include Tal VenaTrac™* insertion stylets PLEASE NOTE: Palindrome™ and Palindrome™ Precision SI are not available in Europe. For further information on available products please contact your local sales representative. |
Palindrome™ Precision HSI–Heparin Coated Dialysis Catheter
Incorporating the heparin coating and silver ion sleeve, the Palindrome Precision HSI-Heparin Coated and Silver Ion Antimicrobial dialysis catheter is the premium dialysis catheter – reducing the likelihood of clot formation AND microbial colonization on the catheter surface.
The Palindrome™ Precision HSI-Heparin Coated and Silver Ion antimicrobial dialysis catheter is intended for acute and chronic hemodialysis, apheresis, and infusion. It may be inserted either percutaneously or by cutdown.
The device is contraindicated in thrombosed vessels or for subclavian puncture when ventilator is in use. This product should not be used in patients with documented hypersensitivity to silver, heparin or porcine based products. Heparin coated catheters should not be used in patients with severe thrombocytopenia, uncontrollable active bleeding disorders, or with skin necrosis from previous heparin use. In case of infection, the silver in the catheter does not replace the need for using systemic anti-infective agents. Clinicians and healthcare professionals should be aware that there are very limited data on prolonged and repeated use of silver containing products and particularly in children and neonates.
See the device manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events.
Order Code |
Description | Arterial Priming Volume (mL) |
Venous Priming Volume (mL) |
Unit of Measure |
Quantity |
---|---|---|---|---|---|
Palindrome™ Precision HSI–Heparin Coated and Silver Ion Antimicrobial Dialysis Catheter Kits | |||||
8888145057P | Palindrome™ Precision HSI-Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | 5 |
8888145048P | Palindrome™ Precision HSI-Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | 5 |
8888145049P | Palindrome™ Precision HSI-Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | 5 |
8888145050P | Palindrome™ Precision HSI-Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | 5 |
Palindrome™ HSI–Heparin Coated and Silver Ion Antimicrobial Dialysis Catheter Kits | |||||
STANDARD TIP | |||||
8888145057 | Palindrome™ HSI–Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 19 cm, Overall Length 36 cm | 1.6 | 1.6 | Carton | 5 |
8888145048 | Palindrome™ HSI–Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 23 cm, Overall Length 40 cm | 1.9 | 1.9 | Carton | 5 |
8888145049 | Palindrome™ HSI–Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 28 cm, Overall Length 45 cm | 2.1 | 2.1 | Carton | 5 |
8888145050 | Palindrome™ HSI–Heparin Coating and Silver Ion Antimicrobial Sleeve, Insertion Length 33 cm, Overall Length 50 cm | 2.3 | 2.3 | Carton | 5 |
*Palindrome™ and Palindrome™ Precision HSI are not available in Europe. For further information on available products please contact your local sales representative |
Palindrome™ Precision RT–Reverse-Tunneled Dialysis Catheter
The Palindrome™ Precision RT–Reverse-Tunneled dialysis catheter allows for precise tip placement and ideal tunnel trajectory using the retrograde tunnel technique.
Order Code |
Description | Arterial Priming Volume (mL) |
Venous Priming Volume (mL) |
Unit of Measure |
Quantity |
---|---|---|---|---|---|
Palindrome™ Precision RT –Reverse Tunneled Dialysis Catheter Kits | |||||
8888541019P | Palindrome™ Precision 15 Fr RT-Reverse Tunneled, Insertion Length 19 cm, Overall Length 39 cm | 1.5 | 1.5 | Carton | 5 |
8888541023P | Palindrome™ Precision 15 Fr RT-Reverse Tunneled, Insertion Length 23 cm, Overall Length 43 cm | 1.7 | 1.7 | Carton | 5 |
8888541028P | Palindrome™ Precision 15 Fr RT-Reverse Tunneled, Insertion Length 28 cm, Overall Length 48 cm | 1.9 | 1.9 | Carton | 5 |
8888541033P | Palindrome™ Precision 15 Fr RT-Reverse Tunneled, Insertion Length 33 cm, Overall Length 53 cm | 2.1 | 2.1 | Carton | 5 |
8888541044P | Palindrome™ Precision 15 Fr RT-Reverse Tunneled, Insertion Length 44 cm, Overall Length 64 cm | 2.5 | 2.5 | Carton | 5 |
8888541055P | Palindrome™ Precision 15 Fr RT-Reverse Tunneled, Insertion Length 55 cm, Overall Length 75 cm | 3.0 | 3.0 | Carton | 5 |
Palindrome™ RT –Reverse Tunneled Dialysis Catheter Kits | |||||
STANDARD TIP | |||||
8888541019 | Palindrome™ 15 Fr RT–Reverse Tunneled, Insertion Length 19 cm, Overall Length 39 cm | 1.5 | 1.5 | Carton | 5 |
8888541023 | Palindrome™ 15 Fr RT–Reverse Tunneled, Insertion Length 23 cm, Overall Length 43 cm | 1.7 | 1.7 | Carton | 5 |
8888541028 | Palindrome™ 15 Fr RT–Reverse Tunneled, Insertion Length 28 cm, Overall Length 48 cm | 1.9 | 1.9 | Carton | 5 |
8888541033 | Palindrome™ 15 Fr RT–Reverse Tunneled, Insertion Length 33c m, Overall Length 53 cm | 2.1 | 2.1 | Carton | 5 |
8888541044 | Palindrome™ 15 Fr RT–Reverse Tunneled, Insertion Length 44 cm, Overall Length 64 cm | 2.5 | 2.5 | Carton | 5 |
8888541055 | Palindrome™ 15 Fr RT–Reverse Tunneled, Insertion Length 55 cm, Overall Length 75 cm | 3.0 | 3.0 | Carton | 5 |
Palindrome™ RT –Reverse Tunneled Dialysis Repair Catheter Kits | |||||
8888541119 | Palindrome™ 14.5 Fr RT–Reverse-Tunneled Repair Kit, Insertion Length 19 cm | Carton | 1 | ||
8888541123 | Palindrome™ 14.5 Fr RT–Reverse-Tunneled Repair Kit, Insertion Length 23 cm |
Carton | 1 | ||
8888541128 | Palindrome™ 14.5 Fr RT–Reverse-Tunneled Repair Kit, Insertion Length 28 cm |
Carton | 1 | ||
8888541133 | Palindrome™ 14.5 Fr RT–Reverse-Tunneled Repair Kit, Insertion Length 33 cm |
Carton | 1 | ||
8888541144 | Palindrome™ 14.5 Fr RT–Reverse-Tunneled Repair Kit, Insertion Length 44 cm |
Carton | 1 | ||
8888541155 | Palindrome™ 14.5 Fr RT–Reverse-Tunneled Repair Kit, Insertion Length 55 cm |
Carton | 1 | ||
*Ensure the catheter repair kit corresponds to the same implant length catheter. |
From their unique design to their innovative coatings and precision tip technology, the Palindrome™ Precision family of chronic hemodialysis catheters reflects our legacy of performance and confidence in innovation.