Professionisti del settore sanitario

<font color="#ffffff">FREEDOM TO </font><br><font color="#ffce00">
<b>DO MORE</b></font>






Valiant Navion
Thoracic Stent Graft System

  

Select the Valiant Navion thoracic stent graft system for your thoracic endovascular aortic repair (TEVAR) procedures. The low-profile delivery system with FreeFlo and CoveredSeal proximal stent graft options are designed for versatility, uncompromising conformability, control, and accuracy. The reimagined design offers enhanced vascular access with a broad set of options to treat a wide range of patient anatomies. The reimagined design, built on proven platforms, offers enhanced vascular access with:

Platform infographic


Indications

The Valiant Navion thoracic stent graft system is indicated for treatment of diseases of the descending thoracic aorta, including but not limited to, aneurysms, dissections, and blunt traumatic aortic injuries (BTAIs). The Valiant Navion thoracic stent graft is indicated for exclusion of the aneurysm, the false lumen, or site of rupture, and the restoration of blood flow through the stent graft lumen. The device is intended for use in patients who are candidates for conventional surgical repair, and in patients who are not candidates for conventional surgical repair due to pre-existing risk factors.


CLINICIAN EXPERIENCES

 

Selection of the Valiant Navion Thoracic Stent Graft System

Dr. Arko discusses why he chooses the Valiant Navion system for his patients.
More information (see more)Less information (see less)

Case with Highly Complex Anatomy

Dr. Nimesh Desai discusses his choice of the Valiant Navion stent graft for complex procedures.
More information (see more)Less information (see less)


PLAN YOUR NEXT CASE

pdf Valiant Navion Stent Graft Sizing Sheet (.pdf)

Use this tool to plan case specifics such as sizing and placement.

129KB


PRODUCT DETAILS

Features

The Valiant Navion™ system is built on our decades of thoracic and abdominal stent graft experience. The Valiant Navion stent graft system has a versatile low-profile design that has optimized flexibility and conformability to adapt to individual patient anatomy and ensures accurate placement.

Low-Profile, Versatile Design

  • FreeFlo configuration with tip capture provides uncompromised control and enhanced conformability for precise accurate placement
  • CoveredSeal configuration with tip capture is a true covered stent that provides uncompromised control and conformability for precise accurate placement

Optimized Access

  • Low profile: 18-22 Fr O.D. crossing profile for enhanced vascular access
  • Hydrophilic coating facilitates stent graft delivery
  • Easy three-step deployment process

Conformability

  • Multi-filament thoracic graft material based on the Endurant™ AAA stent graft yarn and designed for increased flexibility and superior permeability resistance
  • Sinusoidal shape and placement of nitinol springs provide flexibility and conformability
  • Super-elastic nitinol springs exert active radial force to enhance seal and conformability

Accuracy

  • Tip capture provides controlled deployment and precise placement in the thoracic aorta for both FreeFlo and CoveredSeal configurations
  • Tip capture release handle provides simple turn-and-pull motion to release proximal stents for both FreeFlo and CoveredSeal configurations

 

Navion W-Stent

W-Stent & FreeFlo Support Stent
The proximal FreeFlo support stent & CoveredSeal
W-Stent evenly distribute radial force over multiple apices and prevents graft in-folding for optimal seal.

Navion marker

Visible Markers
The stent graft’s spherical platinum iridium markers provide high visibility.

Navion Components

Broad Selection of Pieces
The Valiant Navion thoracic stent graft system offers
a broad selection of components to combine for a
custom fit.


Delivery and Deployment

The Valiant Navion™ delivery system supports control and accurate placement of the stent graft at every step of deployment across a range of anatomies.

Delivery and deployment

Delivery and Deployment with Tip Capture
Deployment, capture, and release of the Valiant Navion stent graft.

Deployment of the Valiant Navion Thoracic Stent Graft System

View an animation of the three-step deployment process.
More information (see more)Less information (see less)

Features of the Valiant Navion delivery system

Features of the Valiant Navion delivery system

  1. Slow, controlled deployment for precise placement
  2. Quick deployment option
  3. Tip capture release

Manuals and Technical Guides

Instructions for Use
Find this technical manual in the Medtronic Manual Library, in the product labeling supplied with each device, or by calling 877-526-7890.


MODEL SPECIFICATIONS

FREEFLO STRAIGHT

Combine the first six columns for the product code.  

  Proximal
Graft
Diameter
(mm)
Distal Graft
Diameter
(mm)

 

Stent Graft
Covered
Length
(mm) 
    Catheter
Outer
Diameter
(Fr)
Vessel
Diameter:
TAA, PAU
(mm)
Vessel
Diameter:
Dissection
(mm)
Vessel
Diameter:
BTAI
(mm)

VNMF

20 20 C 96 TE   18 16-17  19  16-17

VNMF

22 22 C 96 TE   18 18-19  20-22  18-20
VNMF 22 22 C 185 TE   18 18-19  20-22  18-20
VNMF 25 25 C 96 TE   18 20-22  23-25  20-23
VNMF 25 25 C 185 TE   18 20-22  23-25  20-23
VNMF 28 28 C 97 TE   20 23-25  26-28  23-26
VNMF 28 28 C 174 TE   20 23-25  26-28  23-26
VNMF 31 31 C 97 TE   20 26-28  29-30  26-29
VNMF 31 31 C 174 TE   20 26-28  29-30  26-29
VNMF 31 31 C 229 TE   20 26-28  29-30  26-29
VNMF 34 34 C 59 TE   20 28-31  31-33  28-32
VNMF 34 34 C 97 TE   20 28-31  31-33  28-32
VNMF 34 34 C 174 TE   20 28-31  31-33  28-32
VNMF 34 34 C 229 TE   20 28-31  31-33  28-32
VNMF 37 37 C 59 TE   20 30-33  34-36  30-35
VNMF 37 37 C 97 TE   20 30-33  34-36  30-35
VNMF 37 37 C 174 TE   20 30-33  34-36  30-35
VNMF 37 37 C 229 TE   20 30-33  34-36  30-35
VNMF 40 40 C 62 TE   22 33-36  37-39  33-38
VNMF 40 40 C 103 TE   22 33-36  37-39  33-38
VNMF 40 40 C 183 TE   22 33-36  37-39  33-38
VNMF 40 40 C 223 TE   22 33-36  37-39  33-38
VNMF 43 43 C 62 TE   22 36-39  39-42  36-41
VNMF 43 43 C 103 TE   22 36-39  39-42  36-41
VNMF 43 43 C 183 TE   22 36-39  39-42  36-41
VNMF 43 43 C 223 TE   22 36-39  39-42  36-41
VNMF 46 46 C 62 TE   22 39-42  42-45  39-44
VNMF 46 46 C 103 TE   22 39-42  42-45  39-44
VNMF 46 46 C 183 TE   22 39-42  42-45  39-44
VNMF 46 46 C 223 TE   22 39-42  42-45  39-44

FREEFLO TAPERED

Combine the first six columns for the product code.

  Proximal
Graft
Diameter
(mm)
Distal Graft
Diameter
(mm)
  Stent Graft
Covered
Length
(mm)
    Catheter
Outer
Diameter
(Fr)
VNMF 25 20 C 185 TE   18
VNMF 28 22 C 173 TE   20
VNMF 31 25 C 173 TE   20
VNMF 34 28 C 173 TE   20
VNMF 37 31 C 173 TE   20
VNMF 40 34 C 185 TE   22
VNMF 43 37 C 185 TE   22
VNMF 46 40 C 185 TE   22

COVEREDSEAL STRAIGHT

Combine the first six columns for the product code.  

  Proximal
Graft
Diameter
(mm)
Distal Graft
Diameter
(mm)

 

Stent Graft
Covered
Length
(mm) 
    Catheter
Outer
Diameter
(Fr)
Vessel
Diameter:
TAA, PAU
(mm)
Vessel
Diameter:
Dissection
(mm)
Vessel
Diameter:
BTAI
(mm)

VNMC

20 20 C 94 TE   18 16-17  19  16-17

VNMC

22 22 C 94 TE   18 18-19  20-22  18-20
VNMC 22 22 C 180 TE   18 18-19  20-22  18-20
VNMC 25 25 C 94 TE   18 20-22  23-25  20-23
VNMC 25 25 C 180 TE   18 20-22  23-25  20-23
VNMC 28 28 C 90 TE   20 23-25  26-28  23-26
VNMC 28 28 C 182 TE   20 23-25  26-28  23-26
VNMC 31 31 C 90 TE   20 26-28  29-30  26-29
VNMC 31 31 C 182 TE   20 26-28  29-30  26-29
VNMC 31 31 C 223 TE   20 26-28  29-30  26-29
VNMC 34 34 C 52 TE   20 28-31  31-33  28-32
VNMC 34 34 C 90 TE   20 28-31  31-33  28-32
VNMC 34 34 C 182 TE   20 28-31  31-33  28-32
VNMC 34 34 C 223 TE   20 28-31  31-33  28-32
VNMC 37 37 C 52 TE   20 30-33  34-36  30-35
VNMC 37 37 C 90 TE   20 30-33  34-36  30-35
VNMC 37 37 C 182 TE   20 30-33  34-36  30-35
VNMC 37 37 C 223 TE   20 30-33  34-36  30-35
VNMC 40 40 C 55 TE   22 33-36  37-39  33-38
VNMC 40 40 C 95 TE   22 33-36  37-39  33-38
VNMC 40 40 C 175 TE   22 33-36  37-39  33-38
VNMC 40 40 C 218 TE   22 33-36  37-39  33-38
VNMC 43 43 C 55 TE   22 36-39  39-42  36-41
VNMC 43 43 C 95 TE   22 36-39  39-42  36-41
VNMC 43 43 C 175 TE   22 36-39  39-42  36-41
VNMC 43 43 C 218 TE   22 36-39  39-42  36-41
VNMC 46 46 C 55 TE   22 39-42  42-45  39-44
VNMC 46 46 C 95 TE   22 39-42  42-45  39-44
VNMC 46 46 C 175 TE   22 39-42  42-45  39-44
VNMC 46 46 C 218 TE   22 39-42  42-45  39-44

COVEREDSEAL TAPERED

Combine the first six columns for the product code.

  Proximal
Graft
Diameter
(mm)
Distal Graft
Diameter
(mm)
  Stent Graft
Covered
Length
(mm)
    Catheter
Outer
Diameter
(Fr)
VNMC 25 20 C 186 TE   18
VNMC 28 22 C 207 TE   20
VNMC 31 25 C 207 TE   20
VNMC 34 28 C 207 TE   20
VNMC 37 31 C 207 TE   20
VNMC 40 34 C 200 TE   22
VNMC 43 37 C 200 TE   22
VNMC 46 40 C 200 TE   22

Reference
Bench test data on file at Medtronic. Data not indicative of clinical performance.