Overview

Engineered to Enhance Waveform Integrity and Accuracy

Surestream™ patient sampling lines are designed to provide an accurate measure of adequacy of ventilation in both intubated and non-intubated patients, from pediatric to adult.

Surestream™ sampling lines engineered for non-intubated patients include an innovative Uni-junction™ patented design of the patient interface to capture CO2 samples from either the nares or the mouth. A broad range of sizes is available, plus options for nasal sampling only and supplemental O2 delivery.

Surestream™ patient sampling lines for intubated patients accommodate connections to 15 mm or 22 mm endotracheal tubes. An array of sizes for adults and pediatrics are available for both both short-term and long-term monitoring.

Surestream™ patient sampling lines are compatible with Welch Allyn Propaq®* and Atlas™* monitors.

™* and ®* are trademarks and registered trademarks of their respective owners.

Features

Sampling Lines for Non-intubated Patients

Adult SureLine™ O2 and Smart SureLine™ Plus O2 patient sampling line:

  • Oral/nasal sampling with O2 delivery.
  • Oral scoop/prong designed to provide quality CO2 samples when the patient is mouth breathing, even in the presence of low tidal volumes.
  • Delivers oxygen to both nares and orally by producing an “oxygen cloud” in front of the nose and mouth through small holes at the base of the nasal prongs and oral scoop.
  • O2 delivery design reduces CO2 waveform dilution at 5 L/m or less.

Sampling Lines for Intubated Patients

Sure VentLine™ Set:

  • Unique 2-port channel design reduces clogging of sampling lines from moisture and secretions.
  • Airway adapter – performs in any orientation.
  • Able to connect to 15mm or 22mm endotracheal or tracheostomy tubes, ventilatory circuits, closed suction systems and other devices.
  • Moisture reduction technology provides superior moisture handling.

Sure VentLine™ H Set:

  • Unique 2-port channel design reduces clogging of sampling lines from moisture and secretions.
  • Airway adapter – performs in any orientation.
  • Able to connect to 15mm or 22mm endotracheal or tracheostomy tubes, ventilatory circuits, closed suction systems and other devices.
  • Moisture reduction technology provides superior moisture handling.
  • Two sampling ports within airway adapter engineered to reduce clogging from moisture and secretions.
  • Connector design accommodates connection to 15mm or 22mm endotracheal tube.
  • With Nafion®* moisture reduction technology located near sampling port and a filter at monitor end, the design helps manage moisture and secretions, enabling long term use and use in high humidity environments.

*Or alternate moisture reduction technology

®* is a registered trademark of its respective owners.

Order Information