Syncra Cardiac Resynchronization Therapy Pacemaker
(CRT-P)
The Medtronic Syncra® CRT-P system offers essential CRT technologies for heart failure management in patients who are indicated for a bradycardia pacemaker.
How It Works
Syncra™ CRT-P combines industry-leading pacing technology, cardiac resynchronization therapy, and Medtronic exclusive features for essential heart failure management.
- Five pacing vectors
- Ensure CRT with exclusive Left Ventricular Capture Management
- Convenient follow-up with leadless ECG and CareLink® Network
Important Safety Information
Changes in a patient's disease and/or medications may alter the efficacy of a device's programmed parameters or related features.
| Medtronic Exclusives | ||||
|---|---|---|---|---|
| Exclusive | Exclusive | |||
| 5 Pacing Vectors |
LV Capture Management |
Leadless ECG |
CareLink Network |
|
| Syncra™ CRT-P Pacemaker |
• | • | • | • |
Pacing Vectors
Pacing vectors provide flexible programming options
Multiple pacing vectors:
- Address phrenic nerve stimulation with programming flexibility
- Help prevent the need to invasively reposition the implanted lead
- Enhance ability to choose the best configuration for threshold optimization
Ensure CRT
Exclusive Left Ventricular Capture Management™
- Monitors and adjusts LV outputs to automatically balance patient safety and device longevity1
- Ventricular Sense Response and Conducted AF Response automatically ensure CRT even during atrial fibrillation
Manage Atrial Fibrillation
Medtronic AT/AF intervention algorithms:
- Address rhythm control
- Post Mode Switch Overdrive Pacing (PMOP)
- Address rate control
- Conducted AF response
- Provide two AT/AF diagnostics
Reference
- Crossley GH, Mead H, Kleckner K, et al. Automatic left ventricular capture management. Pacing Clin Electrophysiol. October 2007;30(10): 1190-1200.
Leadless ECG
- Exclusive Leadless ECG Waveform for comfortable and convenient patient assessment in-office and within transmissions on the Medtronic CareLink® Network
Medtronic’s Leadless ECG Waveform offers patient comfort and convenience
All patient and clinic data displayed are fictitious and for demonstration purposes only.
- The same in-depth device information that is available in an office visit can be transmitted via the Medtronic CareLink Network
- Timely, remote follow-up for assessing problems earlier
Trending Data
Identify and manage comorbidities:
- Obtain device diagnostic data for identifying and managing a patient’s physiological status1
- Access exclusive 14 months of easy-to-read temporally aligned trends
- Assess the impact of atrial fibrillation on the percentage of BiV pacing
- Assess rate control and atrial fibrillation burden
Trend reports help identify and manage patient comorbidities
All patient and clinic data displayed are fictitious and for demonstration purposes only.
Reference
- Medtronic Syncra CRT-P clinician manual.
Syncra Cardiac Resynchronization Therapy Pacemaker (CRT-P)
15 cc,* 26 g
57 x 59 x 6 mm
8.1 years** longevity
See the Medtronic Syncra CRT-P Pacemaker Clinician Manual.
*Bores open
**600 ohms; 100% atrial pacing; 100% BiV pacing; A and RV Amp = 2.5 V;
LV Amp = 3.0 V; Pre-EGM Storage ON