ICD Defibrillation Leads
 
sprint-quattro-secure

ICD Defibrillation Leads

Sprint Quattro® ICD defibrillator leads offer reliability, energy efficiency and easy handling to best meet the individual needs of patients requiring tachycardia therapy.
 

Important Safety Information

Surgical complications, such as cardiac perforation, may occur and care must be taken when placing and positioning a cardiac lead.

Sprint Quattro Secure – Dual Coil, Active Fixation

Sprint Quattro Secure®

Sprint Quattro Secure® (Model 6947)

The Standard for Exceptional Performance1

  • Model 6947
  • 130,500 US implants1
  • 63 months of exceptional performance1
  • 98.3% Prospective Clinical Study Survival Probability (Medtronic System Longevity Study)1
  • Backed by the most comprehensive performance monitoring system in the industry1

Specifications

Specifications Sprint Quattro Secure 6947
Polarity Dual coil, quadripolar
Fixation Helix, active fixation
Standard lengths 58, 65, 75, 100 cm
Materials
Primary insulation Silicone
Redundant insulation ETFE (cables) and PTFE (coil)
Overlay Isoglide polyurethane
Steroid type Dexamethasone sodium phosphate, 1.0 mg maximum
Electrodes
RV/SVC coils Platinum clad tantalum
Pace/sense Platinized platinum alloy
Diameters
Lead body 8.6 Fr (2.8 mm)
Defibrillation electrodes 8.6 Fr (2.8 mm)
Lead Introducer (recommended sizes)
Without guide wire 9 Fr
With guide wire 11 Fr
Electrodes
Defibrillation, SVC coil  
   Length 8 cm
   Surface area 860 mm2
Defibrillation, RV coil  
   Length 5.7 cm
   Surface area 614 mm2
Ring, surface area 25.2 mm2
Helix, surface area 5.7 mm2
Spacing

8 mm tip-ring
12 mm tip-RV electrode
180 mm tip-SVC electrode

 

Reference

  1. Medtronic CRDM Product Performance Report. 2009. Second Edition. Issue 61.

Sprint Quattro Secure S – Single Coil, Active Fixation

Sprint Quattro Secure S®

Sprint Quattro Secure® S (Model 6935)

The Standard for Exceptional Performance1

  • Model 6935
  • Single coil addition to the Sprint Quattro® family

Specifications

Specifications Sprint Quattro Secure S Model 6935
Polarity Single coil, tripolar
Fixation Helix, active fixation
Standard lengths 52, 58, 65, 75, 100 cm
Materials
Primary insulation Silicone
Redundant insulation ETFE (cables) and PTFE (coil)
Overlay Isoglide polyurethane
Steroid type Dexamethasone sodium phosphate, 1.0 mg maximum
Electrodes
RV coil Platinum clad tantalum
Pace/sense Platinized platinum alloy
Diameters
Lead body 8.6 Fr (2.8 mm)
Defibrillation electrodes 8.6 Fr (2.8 mm)
Lead Introducer (recommended sizes)
Without guide wire 9 Fr
With guide wire 11 Fr
Electrodes
Defibrillation, RV coil  
Length 5.7 cm
Surface area 614 mm2
Ring, surface area 25.2 mm2
Helix, surface area 5.7 mm2
Spacing 8 mm tip-to-ring
12 mm tip-RV electrode

Reference

  1. Medtronic CRDM Product Performance Report. 2009. Second Edition. Issue 61.

Sprint Quattro – Dual Coil, Passive Fixation

Sprint Quattro ICD Defibrillation Lead

Sprint Quattro® (Model 6944)

The Standard for Exceptional Performance1

  • Model 6944
  • 28,600 US implants1
  • 54 months of clinical experience data1
  • 95.8% Prospective Clinical Study Survival Probability (Medtronic System Longevity Study)1
  • Backed by the most comprehensive performance monitoring system in the industry1

Specifications

Specifications Sprint Quattro 6944
Polarity Dual coil, quadripolar
Fixation Tined, passive fixation
Standard lengths 58, 65, 75, 100 cm
Materials
Primary insulation Silicone
Redundant insulation ETFE (cables) and PTFE (coil)
Overlay Isoglide polyurethane
Steroid type Dexamethasone acetate, 1.0 mg maximum
Electrodes
RV/SVC coils Platinum alloy-clad tantalum
Pace/sense Platinized platinum alloy
Diameters
Lead body 8.2 Fr (2.7 mm)
Defbrillation electrodes 8.2 Fr (2.7 mm)
Lead Introducer (recommended sizes)
Without guide wire 9 Fr
With guide wire 10.5 Fr
Electrodes
Defibrillation, SVC coil  
     Length 8 cm
     Surface area 819 mm2
Defibrillation, RV coil  
     Length 5.7 cm
     Surface area 585 mm2
Ring, surface area 17 mm2
Tip, surface area 1.6 mm2
Spacing 8 mm tip-ring
12 mm tip-RV electrode
180 mm tip-SVC electrode

Reference

  1. Medtronic CRDM Product Performance Report. 2009. Second Edition. Issue 61.

Atrial Leads for Patients Needing Pacing Support

CapSure Pacing Leads Family

  • Over a million patients worldwide have benefited from the consistently high performance of Medtronic CapSure® leads
  • Steroid-elution technology reduces inflammation
  • Reduced inflammation allows lower pacing system energy requirements
  • To meet handling preferences, and to address the varying clinical needs of patients, a choice of lead models is available
  • For specifications, visit our family of CapSure Pacing Leads

Subcutaneous Lead System

Model 6996SQ

The Medtronic Subcutaneous Lead System Model 6996SQ is implanted subcutaneously with the use of the Medtronic Tunneling Tool Model 6996T. Improved SQ design and implant technique offer low DFTs, a fast and easy procedure, and high success in complex cases.

  • Significant reduction in DFTs1-3
  • Simple SQ implant approach1-3
  • Flexibility in lead positioning4
  • Long defibrillation coil (25 cm)
    Small lead body (7.5 Fr)
    Introducer (10.5 Fr)
  • Expanded system options

Specifications

Model 6996SQ
Polarity Unipolar
Fixation Sutures on anchoring sleeve
Lead lengths 41, 58 cm
Connector DF-1 unipolar high voltage
Insulation Silicone
Diameters 7.5 Fr body (2.5 mm)
2.3 mm coil (25 cm length)
3.4 mm tip
Introducer 10.5 Fr x 33 cm length
Electrode surface areas Electrical shadow area 18cm2
Defibrillation coil 500 mm2
Model 6996T Tunneling Tool for the 6996SQ Lead
Device Length 421 mm overall
338 mm Tunneling
Material Stainless steel
Tunneling Diameter 3.1 mm

 

References

  1. Dornberger V, Khalighi K, Bail D, et al. Rapid and reliable positioning of a subcutaneous single-finger cardioverter-defibrillator (ICD) lead with transcutaneous guidance (abstract). PACE. 1999;22:4(Part II). Abstract 94.
  2. Kuhlkamp V, Dornberger V, Suchalla R, et al. Effect of a subcutaneous single element array electrode on the defibrillation threshold (abstract). PACE 1999;22:4(Part II). Abstract 680.
  3. Gradaus R, Block M, Seidl K, et al. Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter-defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter-defibrillator: Results from Active Can versus Array Trials I and II. J Cardiovasc Electrophysiol. 2001;12:921-927.
  4. Smits K, Malik M, Lindemans F. A subcutaneous coil electrode added to an active can-RV defibrillator system makes the precise positioning of the RV electrode less important (abstract). PACE 1999;22:4(Part II). Abstract 98.

Transatrial Leads

Transvene 6937A

Specifications

Transvene® 6937A
PolarityUnipolar
FixationNot applicable
Coil length5 cm
ConnectorDF-1
InsulationSilicone with a polyurethane overlay
Diameters7.5 Fr body (2.5 mm)
6.9 Fr electrode (2.3)
Introducer9.0 Fr (without guide wire)
10.5 Fr (with guide wire)
ElectrodeSurface areas 125 mm coil

Transvene Epicardial Patch 6721 (S, M, L)

Specifications

Transvene® Epicardial Patch 6721 (S, M, L)
PolarityUnipolar
FixationSutures
Defib. coilsEpi patch
InsulatorSilicone
Patch dimensions
     6721S (3 Coils)
     6721M (4 Coils)
     6721L (5 Coils)
5.0 cm x 8.0 cm
6.1 cm x 9.1 cm
840 mm
Diameters7.5 Fr body (2.5 mm)
Electrode surface areas
     6721S
     6721M
     6721L
 
370 mm
660 mm
840 mm
Standard length50 cm
Last updated: 24 Jan 2012

Lead Integrity Alert

Learn more about proven shock reduction with advanced warning.

Medtronic Manual Library

manuals-medtronic-com

Find instructions for use and product manuals.

More

Medtronic Connect

connect-thumb

Access the latest in online presentation tools.

More

Medtronic 24-Hour Technical Support

(800) 328-2518