PoleStar
Surgical MRI System

Systems, Software, and Instruments

The PoleStar Surgical MRI Neurosurgery Suite

PoleStar N30 Surgical MRI

PoleStar N30 Surgical MRI

A suite that includes intra-operative MRI from Medtronic includes:

  • PoleStar N30 Surgical MRI system
  • StealthStation® S7™ Surgical Navigation System, with surgeon monitor cart and staff monitor
 

StarShield Portable RF Shield

The PoleStar Surgical iMRI System and StarShield 

PoleStar System and StarShield

The PoleStar® surgical imaging system doesn’t require radio frequency (RF) shielding of the entire OR due to the portable StarShield® RF Shield solution. StarShield is a local, moveable RF shield that can be used to protect the PoleStar surgical imaging device from external RF noise.

StarShield Benefits

  • Reduces overall project costs and complexity by eliminating need for full room RF shielding
  • Significantly reduces OR downtime needed for construction
  • During scanning in surgery, it allows electronic devices to remain turned on in the OR and personnel can come and go at will
The portable StarShield RF is extended during scanning.

StarShield – Extended

The portable StarShield is folded during surgical navigation.

StarShield – Folded

 

OR Positioning

The StarShield is confined to the area around the OR table. It is folded at the patient's feet throughout the surgery, and extended for scanning.

Accessories

The PoleStar System accessories greatly improve the ergonomics, simplify current interfaces, and enhance the overall PoleStar surgical imaging system experience.

Name
Number
Part
Table Adapters
Table Adapter, Maquet, V2 9734017
Table Adapter, Amsco, V2 9734018
Table Adapter, Skytron, V2 9734019
Articulating Arms  
Kit, Articulating Arms, V2, Includes: 9734025
(1) Arm, Multi-link, V2 9734021
(1) Link, L-Shape, V2 9734022
(1) Link, Extension, V2 9734023
Patient Reference Frame (PRF)  
Kit, PRF V2, includes: (1) Arm, PRF, V2 PRF, Interchangeable 9734024
9734020
9733309
Head Support  
Head Arc 9731698
Spherical Adapter Disc 9731702
Head Arc Fastening Nut 9731703
Head Rest, Pediatric Horseshoe NOTE: This headrest is used with gel pads that are not supplied with the unit. These pads must be purchased separately from Integra. Left and right infant horseshoe gel pads are PN 440C1011 and 440C1012. 9733988
Head Holder Sphere 9731704
Head Holder Wrench (for Head Arc Fastening Nut) 9731709
Skull Pins  
Integrated Skull Pin Kit (includes tray and 4 each of L=57, 49, 41, 33, and 25 mm pins) 9733487
Torque Driver 9731713
Torque Driver Bit 9731712
Accessories  
Back Support Plate 9731705
Retractor Attachment 9731708
Accessory Adapter 9731707

 

PoleStar Surgical Imaging System Head Holder V2

Table Adapter

StealthStation Navigation System Integration

PoleStarNavIntegration

iOR Suite with PoleStar

The PoleStar® Surgical MRI System integrates seamlessly with StealthStation® surgical navigation systems.

The PoleStar computer-assisted navigation tools allow:

  • Advanced surgical navigation on pre-operative and intra-operative MRI images
  • Surgical navigation on PoleStar system images merged with pre-operative diagnostic images
  • Surgical navigation without registration of PoleStar system images
  • Concurrent navigation of up to four co-registered image sets (utilizing Compare feature)
  • Integration of microscopes, biopsy solutions, and other procedure specific technology
  • Passive instrument tracking
  • Surgical navigation even when iMRI is not needed

 

Imaging Capabilities

PoleStar Surgical Imaging Capabilities and Highlights

  • Image fusion of pre-operative diagnostic scans (CT, MR, PET and fMRI) with intraoperative images
  • Available scanning sequences  – T1, T2, FLAIR, and e-steady (combination of T1 and T2)
  • Intraoperative scanning times from 8 seconds to 13 minutes
Nav-PituitaryMacroadenoma2

 

PoleStar system image of Low-Grade Glioma

Low-grade Glioma

PoleStar system image of Glioblastoma

Glioblastoma

PoleStar N30 Recent Imaging Upgrades and Improvements

  • Significantly faster and stronger MRI gradient system
  • Higher SNR and shorter imaging times for T2/FLAIR
  • Thinner T2/FLAIR slices for more precise navigation
  • Enhanced imaging of low-grade gliomas – further confirmation of the value of resection control in all types of tumors

Comparison of FLAIR image between the PoleStar N30 and the PoleStar N20 illustrating a reduction in noise
(No Pathology)

Flair

OR Configurations

The PoleStar Surgical Imaging System Retrofits Into Existing ORs

Due to its modular, compact size, the PoleStar® surgical imaging system does not require a specially constructed surgery suite. It can inexpensively retrofit existing ORs, located on any floor of the building.

PoleStar-OR

PoleStar N20 Surgical MRI in the OR.

PoleStar-Stowed

PoleStar N20 Surgical MRI stowed under the operating table.

 

Sample OR Configuration

A sample OR configuration with the PoleStar surgical imaging system.

RF Shield Positioning

StarShield

StarShield – Extended for Scanning

StarShield Surgery

StarShield – Folded During Surgery

 

The PoleStar surgical imaging system doesn't require RF shielding of the entire OR. The portable StarShield® RF Shield – a local, moveable RF shield – can be used to shield the PoleStar surgical imaging system from external RF noise.

PoleStar Surgical Imaging System Storage

The entire unit can be wheeled to the patient table and resides underneath the table when not in use and is then elevated back to its scanning position with the push of a button.

When the OR is using the PoleStar surgical imaging system for navigation alone, the PoleStar scanner is stored in the Magnet Storage Cabinet, which contains the PoleStar's magnetic field to eliminate it from the OR.

Magnetic Storage

PoleStar system magnetic storage cabinet

PS-Storage-open

PoleStar system stowed in magnetic storage cabinet

 

Note: The PoleStar magnetic field is confined to the volume between the magnet poles and its immediate area. Surgical tools and systems outside the magnetic field will not be affected by the PoleStar's presence. Life support equipment as well as instruments that remain in the surgical field during scans must be MRI-compatible. All other instruments should be of a non-ferromagnetic material.

Site Preparation Guide

A Site Preparation Guide is provided to aid you and your organization in preparing for the installation of the PoleStar MRI system. A company-certified Site Preparation Specialist will be involved in all stages of your OR preparation, including consulting with the personnel at your facility during the design stage and monitoring the entire construction process.

Best Practices

The design of the PoleStar® system is optimized for performing intracranial operations. The gap between the magnet poles accommodates all clinically required head positions while allowing the surgeon to conveniently access the surgical site whether the magnets are in scan position or lowered under the OR table. The system's dedicated Head Holder System provides both traditional three-pin and pinless fixation.

Step-by-Step Procedure

procedure1

While the patient is anesthetized, PoleStar remains in its storage cabinet enabling the medical personnel unrestricted access to the patient.

procedure2

The patient is positioned in the system Head Holder.

procedure3

The magnet is positioned and preoperative images are acquired.

procedure4

Gadolinium-enhanced images show the location of the tumor.

procedure5

The images are used for planning the craniotomy.

procedure6

The magnet is lowered and the tumor resection is performed.

 procedure7

An intraoperative image acquisition is performed, revealing residual tumor.

 SNAP011

Navigation based on the intraoperatively acquired images allows the surgeons to precisely locate the residual tumor.

procedure9

The surgery continues using the guidance of intraoperative StealthStation® navigation.

 

Treon-Compare

Online comparison of images acquired at different stages of the surgery facilitates complete removal of the tumor.

Last updated: 26 Feb 2013

Featured Product

StealthViz Advanced Visualization and Planning, coupled with the StealthStation, enable surgeons with the best possible info in the OR.