Product image of the Axium™ prime soft coil
No Image Available

Detachable coils

Axium™ Prime soft coil

<p>Axium™ Prime Soft detachable coils are designed to maximize packing without sacrificing softness.<sup>16</sup></p>

Innovative and comprehensive portfolio

Where innovation drives reliability

The comprehensive Medtronic Axium™ coils portfolio delivers the consistent clinical outcomes you demand - reliable detachment,†,9-11 effective occlusion1,3,12 and soft deployment.†, 1-6

Backy by rigorous quality standards, the Axium™ coils family offers expert precision,4-9 control9 and safety.†,1-9


† Data derived from reference bench testing may not be representative of clinical performance, 4-8-HX Microplex coil n=3, 4-8-HX Target® Ultra coil n=3, 4-8-HX Axium™ Prime coil n=5


Features

Axium™ coil family provides optimal implant designs for a variety of coiling procedures with our framing, filling, and finishing coils. Axium™ products provide proven softness, high-volume packing, minimal kickback, and exceptional detachment. ‡,3,5–10

99.7%

Proven reliability with first attempt detachment success9-11

 

 

Better trackability through tortuous anatomy§,12,14

Distal tapered pusher design allows for increased articulation and enhanced trackability13,15

Minimal micro catheter kick-back

Ball and socket design allows for 360° axial rotation which facilitates coil delivery with less micro catheter kick-back13–16


The entire Axium™ family of coils features a progressive outer diameter matched to the implant size, which optimizes stability and volume throughout the entire coil line.5


‡ Based on bench test comparing average work number of Axium™ Prime Extra Soft coil versus Target® Nano coil. 20 units of each coil were tested. Bench testing is not indicative of clinical performance.; Determined using formula for cylinder (volume = πr2 x length). Based on calculated k-factor values

§ Data derived from reference bench testing may not be representative of clinical performance.


Characteristics

Coil outer diameter (in) 0.0115 0.0125 0.0135 0.0145
Diameter (mm) 3.0–3.5 4.0–6.0 7.0–10.0 12.0–25.0
Length (cm) 6–10 6.0–25.0 12.0–40.0 30.0–50.0
Volume (mm3) 4.02–6.70 4.75–19.79 11.08–36.94  31.96–53.27

Ordering information

Axium™ Prime soft 3-D coils

Item number Coil diameter (mm) Implant length (cm) Primary coil outer diameter (in)
APB-4-6-3D-SS 4 6 0.0115
APB-4-8-3D-SS 4 8 0.0115
APB-4-10-3D-SS 4 10 0.0115
APB-4-12-3D-SS 4 12 0.0115
APB-5-8-3D-SS 5 8 0.0115
APB-5-10-3D-SS 5 10 0.0115
APB-5-15-3D-SS 5 15 0.0115
APB-6-10-3D-SS 6 10 0.0115
APB-6-15-3D-SS 6 15 0.0115
APB-6-20-3D-SS 6 20 0.0115

Axium™ Prime soft helix coils

Item number Coil diameter (mm) Implant length (cm) Primary coil outer diameter (in)
APB-4-6-HX-SS 4 6 0.0115
APB-4-8-HX-SS 4 8 0.0115
APB-4-10-HX-SS 4 10 0.0115
APB-4-12-HX-SS 4 12 0.0115
APB-5-10-HX-SS 5 10 0.0115
APB-5-15-HX-SS 5 15 0.0115
APB-5-20-HX-SS 5 20 0.0115
APB-6-12-HX-SS 6 12 0.0115
APB-6-20-HX-SS 6 20 0.0115

TM* Third party brands are trademarks of their respective owners.

  1. Based on internal test report D01070173, Competitive test report for Axium™. December 2023. 
  2. Based on internal test report TR-NV10218. Super Soft Coil Implant Feasibility Study Report. June 2011. Compared to Axium™ 4-6mm coils; TR-NV10304. Axium™ Prime Super Soft Design Validation. December 2011.
  3. M045839CDOC2 - Axium™ 3D Detachable Coils Indications for Use.
  4. TR-NV12051 Axium™ Prime Finishing Coils Design Validation Report. March 2015.
  5. Based on internal test report TR-NV12442. Bench test comparing average work number of Axium™ Prime Extra Soft coil versus Target™* Nano™* coil. 20 units of each coil were tested. September 2015.
  6. Based on internal test report TR-NV12197, Axium™ Prime 1.5mm 3D Finishing Coils Design Verification and Validation Adoption. Rev B.
  7. Based on internal test report TRNV-10304, Axium™ Prime Super Soft Design Validation Report. Rev A.
  8. Based on internal test report TR09-218, Axium™ Prime Reliability Test Report. Rev A.
  9. Based on internal test report TR-NV13164, Design Verification and Validation Adoption Report Fitz Roy. Rev C.
  10. Based on internal test report D00776522, Axium™, Axium™ Prime, Concerto Competitor Detachment Reliability Marketing Report. Rev A.
  11. Based on internal test report TR10-126, NG Axium™ Pusher Unibody Feasibility Report. Rev A.
  12. Based on internal test report TR-NV12481, Axium™ Prime Coil Extra Soft Field Training Material. Rev A.
  13. Based on internal test report TR-NV13175, Fitz Roy Design Verification Test Report. Rev D.
  14. Based on internal test report FD3117, Implant Articulation Test, Axium™/Axium™ Prime Vs. Competitors. Rev A.
  15. Based on internal test report FD3118, Implant Layup Test, Axium™/Axium™ Prime Vs. Competitors. Rev A.
  16. US-NEU-2400072 (v1.0)