Detachable coils
Axium™ Prime soft coil
<p>Axium™ Prime Soft detachable coils are designed to maximize packing without sacrificing softness.<sup>16</sup></p>
Innovative and comprehensive portfolio
Where innovation drives reliability
The comprehensive Medtronic Axium™ coils portfolio delivers the consistent clinical outcomes you demand - reliable detachment,†,9-11 effective occlusion1,3,12 and soft deployment.†, 1-6
Backy by rigorous quality standards, the Axium™ coils family offers expert precision,4-9 control9 and safety.†,1-9
Instant, reliable detachment†,9-11
Proven
softness†,1-6
High-volume
packing1,3,12
† Data derived from reference bench testing may not be representative of clinical performance, 4-8-HX Microplex coil n=3, 4-8-HX Target® Ultra coil n=3, 4-8-HX Axium™ Prime coil n=5
Features
Axium™ coil family provides optimal implant designs for a variety of coiling procedures with our framing, filling, and finishing coils. Axium™ products provide proven softness, high-volume packing, minimal kickback, and exceptional detachment. ‡,3,5–10
The entire Axium™ family of coils features a progressive outer diameter matched to the implant size, which optimizes stability and volume throughout the entire coil line.5
‡ Based on bench test comparing average work number of Axium™ Prime Extra Soft coil versus Target® Nano coil. 20 units of each coil were tested. Bench testing is not indicative of clinical performance.; Determined using formula for cylinder (volume = πr2 x length). Based on calculated k-factor values
§ Data derived from reference bench testing may not be representative of clinical performance.
Characteristics
| Coil outer diameter (in) | 0.0115 | 0.0125 | 0.0135 | 0.0145 |
| Diameter (mm) | 3.0–3.5 | 4.0–6.0 | 7.0–10.0 | 12.0–25.0 |
| Length (cm) | 6–10 | 6.0–25.0 | 12.0–40.0 | 30.0–50.0 |
| Volume (mm3) | 4.02–6.70 | 4.75–19.79 | 11.08–36.94 | 31.96–53.27 |
Ordering information
| Item number | Coil diameter (mm) | Implant length (cm) | Primary coil outer diameter (in) |
|---|---|---|---|
| APB-4-6-3D-SS | 4 | 6 | 0.0115 |
| APB-4-8-3D-SS | 4 | 8 | 0.0115 |
| APB-4-10-3D-SS | 4 | 10 | 0.0115 |
| APB-4-12-3D-SS | 4 | 12 | 0.0115 |
| APB-5-8-3D-SS | 5 | 8 | 0.0115 |
| APB-5-10-3D-SS | 5 | 10 | 0.0115 |
| APB-5-15-3D-SS | 5 | 15 | 0.0115 |
| APB-6-10-3D-SS | 6 | 10 | 0.0115 |
| APB-6-15-3D-SS | 6 | 15 | 0.0115 |
| APB-6-20-3D-SS | 6 | 20 | 0.0115 |
Axium™ Prime soft helix coils
| Item number | Coil diameter (mm) | Implant length (cm) | Primary coil outer diameter (in) |
|---|---|---|---|
| APB-4-6-HX-SS | 4 | 6 | 0.0115 |
| APB-4-8-HX-SS | 4 | 8 | 0.0115 |
| APB-4-10-HX-SS | 4 | 10 | 0.0115 |
| APB-4-12-HX-SS | 4 | 12 | 0.0115 |
| APB-5-10-HX-SS | 5 | 10 | 0.0115 |
| APB-5-15-HX-SS | 5 | 15 | 0.0115 |
| APB-5-20-HX-SS | 5 | 20 | 0.0115 |
| APB-6-12-HX-SS | 6 | 12 | 0.0115 |
| APB-6-20-HX-SS | 6 | 20 | 0.0115 |
Related products
Similar products
-
Axium™ MicroFX™ coilThe Axium MicroFX™ coil is designed to reduce blood flow across aneurysms and offers an alternative to bare coils for AV fistulae and abnormalities.
-
Axium™ Prime extra soft coilThe Axium™ Prime Extra soft detachable coil is designed to maximize packing without sacrificing softness in treating intracranial aneurysms.18
-
Axium™ Prime frame coilThe Axium™ Prime Frame coil has a unique hybrid loop configuration and is a stable first coil option for various aneurysm shapes and neck sizes.15
-
Axium™ QC coilThe Axium™ QC coil is an endovascular device that comes in 83 sizes and has a high packing volume to treat intracranial aneurysms.
TM* Third party brands are trademarks of their respective owners.
- Based on internal test report D01070173, Competitive test report for Axium™. December 2023.
- Based on internal test report TR-NV10218. Super Soft Coil Implant Feasibility Study Report. June 2011. Compared to Axium™ 4-6mm coils; TR-NV10304. Axium™ Prime Super Soft Design Validation. December 2011.
- M045839CDOC2 - Axium™ 3D Detachable Coils Indications for Use.
- TR-NV12051 Axium™ Prime Finishing Coils Design Validation Report. March 2015.
- Based on internal test report TR-NV12442. Bench test comparing average work number of Axium™ Prime Extra Soft coil versus Target™* Nano™* coil. 20 units of each coil were tested. September 2015.
- Based on internal test report TR-NV12197, Axium™ Prime 1.5mm 3D Finishing Coils Design Verification and Validation Adoption. Rev B.
- Based on internal test report TRNV-10304, Axium™ Prime Super Soft Design Validation Report. Rev A.
- Based on internal test report TR09-218, Axium™ Prime Reliability Test Report. Rev A.
- Based on internal test report TR-NV13164, Design Verification and Validation Adoption Report Fitz Roy. Rev C.
- Based on internal test report D00776522, Axium™, Axium™ Prime, Concerto Competitor Detachment Reliability Marketing Report. Rev A.
- Based on internal test report TR10-126, NG Axium™ Pusher Unibody Feasibility Report. Rev A.
- Based on internal test report TR-NV12481, Axium™ Prime Coil Extra Soft Field Training Material. Rev A.
- Based on internal test report TR-NV13175, Fitz Roy Design Verification Test Report. Rev D.
- Based on internal test report FD3117, Implant Articulation Test, Axium™/Axium™ Prime Vs. Competitors. Rev A.
- Based on internal test report FD3118, Implant Layup Test, Axium™/Axium™ Prime Vs. Competitors. Rev A.
- US-NEU-2400072 (v1.0)