No Image Available

Liquid embolics

Onyx™ liquid embolic system

<p>Onyx™ LES is for embolization of peripheral and neurovascular lesions including AVMs &amp; hypervascular tumors. Onyx™ 12 is for neurovascular lesions.</p>

Features

Control2

Cohesive deposition

Provides a responsive, controlled injection of Onyx™ LES to achieve nidal penetration

Visibility2

Know where it flows

Provides live feedback of the embolic fill & trajectory, enabling visibility of Onyx™ injection under fluoroscopy

Evidence3,4

Proven performance

Evidence market leader with 330+ global neurovascular publications on Onyx™ LES. Available in the European market since 1999.

Onyx™ 12, 18, 20 & 34 portfolio6

Cohesive properties allow for controlled, gradual injection, minimizing the risk of non-target embolization and facilitating deeper penetration.10,11

Consistent, distal, and homogeneous distribution within the MMA branches, enabling more complete and durable embolization of the target vasculature.13

onyx fluid still neon

Viscosity is set by EVOH concentration

  Viscosity EVOH %
Onyx™ 34 28.3 - 34.6 cSt 8.00%
Onyx™ 18 15.1 - 18.5 cSt 6.00%
Onyx™ 12 12.0 - 15.0 cST 5.25%

Onyx™ LES compatible flow-directed micro catheters

The Apollo™ Onyx™ and Marathon™,‡ delivery micro catheters have been expressly designed to complement and enhance embolization with Onyx™ LES. These synergistic tools help you journey to more tortuous locations, embolize more challenging lesions, and return with confidence.5-8

Marathon™ and Apollo™ flow-directed catheters have been expressly designed to complement and enhance embolization with Onyx™ LES.

Ordering information

Onyx™ liquid embolic system is offered in 12, 18, 20 and 34 to provide options for controllable injections.1

Item number Description
105-7100-040 Onyx™ 12 LES
105-7000-060 Onyx™ 18 LES
105-7000-065 Onyx™ 20 LES
105-7100-080 Onyx™ 34 LES

 

The Onyx™ 12, 18, 20 and 34 LES Kits contain1:

  • 1.5 mL vial of Onyx™ LES (1)
  • 1.5 mL vial of DMSO (1)
  • 1 mL DMSO syringe (1)
  • 1 mL Onyx™ LES syringe (1)

Onyx™ liquid embolic system accessories

The Onyx™ Liquid Embolic System mixer (shaker) is packaged one unit per box. It contains four spaces for preparation of Onyx™ Liquid Embolic System vials simultaneously.

Item number Description Units per box
103-1205-002 Vial mixer, 15–17 mm, 240 V 1
103-1205-100 Mixer attachment 1


The Cadence™ Precision Injector Accessory provides precision inflation of balloon catheters: 0.02 ml inflation per roation offers tactile feedback.13

Cadence™ Precision Injector Accessory
Product Catalog Number Capacity (ml) Syringes/ Boxes
103-0304 1 5
1 ml Injection Syringe
Product Catalog Number Capacity (ml) Syringes/ Boxes
103-1203 1 5
Syringe Adapter
Product Catalog Number Description
103-1207 Onyx™ Syringe Adapter 20/box

 

Apollo™ Onyx™ Delivery Microcatheter with a detachable tip, is designed with a stainless steel proximal coil for high kink resistance and distal nitinol braiding for reinforcement.5

Apollo™ Onyx™ Delivery Microcatheter  
Product Catalog Number Proximal Outer Diameter (F/in) Distal Outer Diameter (F/ in) Inner Diameter (in) Usable Length (cm) Tip Length (cm) Tip Shape Wire Compatibility (in) Minimum Dead Space (ml)
105-5095-000 2.7/ 0.035 1.5/ 0.020 0.013 165 1.5 Straight 0.008 & 0.010 hydrophilic 0.023 (≥ 0.20 with adapter)
105-5096-000 2.7/ 0.035 1.5/ 0.020 0.013 165 3.0 Straight 0.008 & 0.010 hydrophilic 0.023 (≥ 0.20 with adapter)
105-5097-000 2.7/ 0.035 1.5/ 0.020 0.013 165 5.0 Straight 0.008 & 0.010 hydrophilic 0.023 (≥ 0.20 with adapter)

 

Marathon™ is a Flow Directed Microcatheter with a proximal stainless steel coil for great proximal support and a nitinol distal braiding for high kink resistance for optimised delivery of Onyx™ Liquid Embolic System.8-12

Marathon™ Flow Directed Microcatheter  
Product Catalog Number Stylet Outer Diameter (in) Inner Diameter (in) Usable Length (cm) Distal Length (cm) Max Guidewire (in) Minimum Dead Space (ml)
105-5056 Without 2.7 > 1.5 0.013 165 25 0.010 0.023 

 

Echelon™ Micro Catheter
Product Catalog Number Working lenght (cm) OD (F) ID (in) Dead space volume (ml) Tip shape
105-5091-150  150  2.1 > 1.7  0.017  0.34  Straight 
145-5091-150  150  2.1 > 1.7  0.017  0.34  45°
190-5091-150  150   2.1 > 1.7  0.017  0.34 90°
105-5092-150  150  2.4 > 1.9 0.017  0.34  Straight 
145-5092-150  150 2.4 > 1.9  0.017  0.34 45° 
190-5092-150   150  2.4 > 1.9  0.017 0.34  90°

 

Rist™ Radial Access Guide Catheter 
Product Catalog Number Working lenght (cm) OD (in/F) ID (in) Hydrophilic coating length (cm)
106F-071-95  95  0.087 Max/6F  0.071  25 
106F-071-100   100  0.087 Max/6F 0.071  25
106F-071-105  105 0.087 Max/6F  0.071 25 
107F-079-95   95  0.093 Max/7F  0.079  25
107F-079-100  100  0.093 Max/7F   0.079  25
107F-079-105   105  0.093 Max/7F  0.079  25

 

Mirage™ 0.008” Hydrophilic Guidewire 
Product Catalog Number Usable lenght (cm) Diameter (in) Coil length (cm)
103-0608  200  0.012 > 0.008  10 

 

Phenom™ Plus Catheter   
Product Catalog Number Working lenght (cm) Proximal outer diameter (in) Distal outer diameter (in) Catheter inner diameter (in)
FG19120-1030-1S  120   0.061  0.055  0.0445

† Please note that some of these studies were conducted OUS and may not comply with the U.S. indications for use. See IFU for U.S. indication.

‡ Based on bench testing. May not be representative of clinical performance.

*EMBOLISE: Davies JM et al. Adjunctive Middle Meningeal Artery Embolization for Subdural Hematoma. N Engl J Med. 2024 Nov 21;391(20):1890-1900. doi: 10.1056/NEJMoa2313472. PMID: 39565988. MAGIC-MT: Liu J. Middle Meningeal Artery Embolization for Nonacute Subdural Hematoma. N Engl J Med. 2024 Nov 21; 391(12):1901-1912. doi: 10.1056/NEJMoa2401201. PMID: 39565989 EMMA-Can: Shankar JJS, Alcock S, Kashani N, et al. Management of Chronic Subdural Hematoma With Adjunctive Embolization of Middle Meningeal Artery: The EMMA-Can Randomized Clinical Trial. JAMA. Published online April 30, 2026. doi:10.1001/jama.2026.4910 OTEMACS: Presented at SLICE 2025 on April 2, 2025 by Sam Ng, MD, MSc; NCT04742920 2025-csdh-talk-track-en-gb--17399275

  1. Onyx™ Liquid Embolic System IFU, 70862-001 Rev 10/13.
  2. Based on internal design verification test report #TR02-092 Rev A, Low Density Onyx™ (18, 20, and 34) with Increased Tantalum Concentrations. 
  3. Onyx™ LES PMA #P030004.
  4. Based on internal clinical evaluation (literature review) report #TR-NV12982 Rev L, Onyx™ LES, 1 mL Onyx™ LES Delivery Syringe, and Onyx Syringe Catheter Interface Adaptor.
  5. Apollo™ Onyx™ Delivery Micro Catheter IFU, 70556-001 Rev. 05/13.
  6. Based on internal design verification test report #TR03-106 Rev A, Marathon™ AVM Catheter Model #: 105-5055.
  7. Meyers PM et al., Safety of the Apollo™ Onyx™ delivery microcatheter for embolization of brain arteriovenous malformations: results from a prospective post-market study. J Neurointerv Surg. 2021 Oct;13(10):935-941. doi: 10.1136/neurintsurg-2020-016830. Epub 2021 Feb 1. PMID: 33526480.
  8. Marathon IFU M008556CDOC4 Rev. D (08/2024)
  9. TR03-106, Design Verification Marathon AVM Catheter Model 105-5055. Rev A. 
  10. TR03-106ADD2, Marathon AVM Micro Catheter Design Verification Testing Addendum Test Report. Rev A. 
  11. D00229257, Apollo and Marathon Hub Design Change Design Verification Report. Rev A. 
  12. DWGS105-5056, Marathon165cm AVM Micro Catheter (no stylet) drawing. Rev J.
  13. Cadence™ Precision Injector Thread 1 mL Syringe M993508ADOC2 Rev. D (07/2022)

  1. Ierardi, A. M., Femia, M., Petrillo, M., Angileri, S. A., Hörer, T., & Carrafiello, G. (2018). The Onyx Liquid Embolic System: Another Chance in the Management of Peripheral Bleeding. Journal of Endovascular Resuscitation and Trauma Management, 2(2), 49–56. https://doi.org/10.26676/jevtm.v2i2.46
  2. Kojima T, Maeda T, Ito Y, Kikuta H, Fujii M. Onyx Liquid Embolic Agent: Basic Knowledge for Its Use in Interventional Neuroradiology. J Neuroendovasc Ther. 2025;19(1): 2024-0073. doi: 10.5797/jnet.ra.2024-0073. Epub 2024 Oct 29. PMID: 40007973; PMCID: PMC11850992.
  3. R.V. Chandra, T.M. Leslie-Mazwi, B.P. Mehta, A.J. Yoo, J.D. Rabinov, J.C. Pryor, J.A. Hirsch, R.G. Nogueira Transarterial Onyx Embolization of Cranial Dural Arteriovenous Fistulas: Long-Term Follow-Up American Journal of Neuroradiology Sep 2014, 35 (9) 1793-1797; DOI: 10.3174/ajnr.A3938