Your browser is out of date

With an updated browser, you will have a better Medtronic website experience. Update my browser now.

×

Skip to main content

Description

The Valleylab™ SM smoke management pencil provides smoke capture, in a lightweight ergonomic offering. This pencil allows surgeons to be confident they are effectively addressing surgical smoke at the source, protecting staff and patients alike.

Features



Valleylab™ SM pencil

Striking the right balance between size, ergonomics, and smoke capture†,1 — the Valleylab™ SM pencil delivers superior air flow‡,§,2 and smoke removal§,◊,2 in a compact, narrow design.¶,2

Valleylab™ SM smoke management pencil

Superior clinical performance

  • 30% higher air flow§,#,2
  • More efficient smoke capture¶,2

Enhanced ergonomics

  • Supports natural hand and wrist movementΔ,1
  • A lightweight and natural feel†,1

Seamless integration

  • Easy set up†,1
  • As natural to use as a standard electrosurgery pencilΔ,1
The Valleylab™ SM smoke management pencil showing numbered features.
1. 360 degrees of freedom

A 360-degree swivel supports natural hand and wrist movement.Δ,1

2. Get a grip.

Nonslip buttons are easy to use when you’re wearing gloves.∞,1

3. A clear vision

A transparent tip for good visibility at the surgical siteΔ,1

4. Access granted

Optimal access to the surgical site‡‡,1,3

5. Keep a low profile.

A compact, low-profile design¶,2 means the Valleylab™ SM pencil fits into your OR environment.

6. Wired for efficiency

An integrated ESU wire simplifies cord management during your procedures.††,8

Ordering information

Item number Description Length Items per box

VSMEN4

Valleylab™ SM smoke management extended nozzle electrode

4 inches

80

VSMEN6

Valleylab™ SM smoke management extended nozzle electrode

6.5 inches

80

VSMP10

Valleylab™ SM smoke management extended nozzle with Edge™ electrode

10 feet

20

VSMP10NSB

Valleylab™ SM smoke management extended nozzle with Edge™ electrode, (nonsterile bulk)

10 feet

30

VSMP15

Valleylab™ SM smoke management extended nozzle with Edge™ electrode

15 feet

20

Resources


 


 

† 17 out of 17 OR staff agreed.

‡ Compared to Stryker SafeAir™* smoke evacuation pencil™*, MEGADYNE™* Zip Pen™* pencil, Conmed PlumePen™* Pro slim pencils, and Conmed GoldVac™* slim pencils.

§ Tested on bench tissue model with RapidVac™ smoke evacuator system at 100% (5 dots), 10 ft configurations. Bench testing may not be indicative of clinical performance.

◊ Compared to ConMed PlumePen™* Elite pencil, MEGADYNE™* Zip Pen™* pencil, and ConMed GoldVac™* slim pencils.

¶ Compared to Valleylab™ smoke evacuation rocker switch pencil, Edge™ blade electrode.

# Compared to Stryker SafeAir™* smoke evacuation pencil™*.

Δ 16 out of 17 surgeons agreed.

∞ 14 out of 17 surgeons agreed.

†† Cable is integrated for the first three feet.

‡‡ 15 out of 17 surgeons agreed.

1

Based on internal test report RE00507394 , Valleylab™ smoke management pencil marketing claims testing report. July 12–19, 2023.

2

Based on internal test report RE00486994, Valleylab™ smoke management pencil marketing claims testing report. December 6–7, 2023.

3

Based on internal test report RE00460034, SPD-88 report surgeon summative Lucky Strike. 2011;8447-466.

4

Pierce JS, Lacey SE, Lippert JF, Lopez R, Franke JE. Laser-generated air contaminants from medical laser applications: a state-of-the-science review of exposure characterization, health effects, and control. J Occup Environ Hyg. 2011 Jul;8(7):447–466.

5

Hill DS, O'Neill JK, Powell RJ, Oliver DW. Surgical smoke - a health hazard in the operating theatre: a study to quantify exposure and a survey of the use of smoke extractor systems in UK plastic surgery units. J Plast Reconstr Aesthet Surg. 2012;65(7):911–916.

6

Ball K. Surgical smoke evacuation guidelines: compliance among perioperative nurses. AORN J. 2010;92(2):e1–23.

7

Moss, C Eugene. Control of Smoke From Laser/Electric Surgical Procedures Department of Health and Human Services (NIOSH). Publication number 96–128. September 1996.

8

Based on product design, Valleylab™ SM smoke managment pencil, ASSY, VSMP1X.