Evolut™ FX System for transcatheter aortic valve implantation (TAVI)

The Evolut™ FX transcatheter aortic valve system sets new expectations for precision, control, and predictability in TAVI procedures.

Contact us

Overview

Predictable performance

The Evolut™ FX system enhancements make TAVI procedures easier to visualize and more predictable.

Features

Design goals

Precision. Control. Predictability.

Optimized stability layer for more predictable deployment

Redesigned tip and increased capsule flexibility for more dilator-like access and to better accommodate the most challenging anatomies

Single-spine shaft for greater flexibility and improved deliverability

Enhanced visualization
Radiopaque markers provide a reference for deployment depth and commissure location.

Performance as compared to Evolut™ PRO+ system in bench testing. Bench testing may not be indicative of clinical performance.

Performance in bench testing

Deployment stability

The Evolut™ FX stability layer increases catheter support during deployment and provides 50% less ventricular movement.*

Evolut™ FX conforms to the native anatomy more easily for a 36% improvement in deployment coaxiality.*

Deliverability

The Evolut™ FX system has a 33% reduction in insertion force (smoother) into simulated vasculature with a more flexible capsule.*

Evolut™ FX nosecone

Illustration of the Evolut™ FX nosecone flexible capsule

Evolut™ PRO+ nosecone

Illustration of the Evolut™ PRO+ nosecone flexible capsule

The Evolut™ FX system has a 38% reduction in tracking force in challenging anatomies.*

 33%   

reduction in insertion force*

 38%   

reduced
tracking force*

The Evolut™ FX system increases flexibility for 360° range of motion for greater control.*

Illustration showing the range of motion of the Evolut™ PRO+ TAV system
Illustration showing the range of motion of the Evolut™ FX TAV system

Ordering information

Bioprosthesis — Evolut™ FX valve

Item number Valve size (mm) Aortic annulus diameter (mm)

EVOLUTFX-23

23

17/18–20

EVOLUTFX-26

26

20–23

EVOLUTFX-29

29

23–26

EVOLUTFX-34

34

26-30

Loading system — Evolut™ FX loading system

Item number Description

L-EVOLUTFX-2329

Loading system for use with 23, 26, and 29 mm TAV

L-EVOLUTFX-34

Loading system for use with 34 mm TAV

Delivery catheter system — Evolut™ FX delivery catheter system with InLine™ sheath

Item number Description Delivery system size Delivery system working length (cm)

D-EVOLUTFX-2329

Delivery system for use with 23, 26, 29 mm TAV

14 Fr equivalent (6 mm capsule outer diameter)

108

D-EVOLUTFX-34

Delivery system for use with 34 mm TAV

18 Fr equivalent (7.33 mm capsule outer diameter)

108

Resources

Similar products

Confida ヒーロー画像

Confida™ Brecker guidewire

The Confida™ Brecker guidewire is specifically designed for transcatheter aortic valve replacement (TAVI) procedures.

View the Evolut™ FX+ TAV with a green highlighted area in the center.

Evolut™ FX+ system 

The Evolut™ FX+ transcatheter aortic valve system is designed with specific features intended to enable lifetime management solutions such as coronary access. 

Evolut™ PRO+ transcatheter aortic valve shown from an angled top-down view

Evolut™ PRO+ system

The Evolut™ PRO+ TAVI system features the lowest delivery profile for 23–29 mm valves and advanced sealing with an external tissue wrap on all valve sizes.

*

Performance as compared to Evolut™ PRO+ system in bench testing. Bench testing may not be indicative of clinical performance.

Measurement for TAV-in-SAV only.