Overview

Whichever you choose, our masks go with your flow.

Help keep your patients safe from sedation adverse events with all-new open and closed EtCO2 mask options.

Oxy2Pro™* with Microstream™  connector

An all-new closed design with an improved diffuser1 to help you better manage oxygenation and ventilation during sedation procedures with higher O2 needs.

Oxy2Mask™* EtCO2 with Microstream™  connector

An all-new open design with an improved diffuser1 to help you monitor and better manage oxygenation and ventilation for patients before, during, and after sedation procedures. This open mask design allows for enhanced patient comfort with a broader FiO2 range.

Both masks are built using a Microstream™ Advance filter line and connect to any Microstream™ capnography or Microstream™ technology-enabled monitor for etCO2 readings. Microstream™ technology offers:

  • Reduced nuisance alarms using smart alarm management2
  • Real-time indication of oxygen and ventilation changes
  • Tracks apnea events, CO2, SpO2, pulse rate, and respiration rate

Open or closed — your patients are covered

Oxy2Pro™* with Microstream™ Connector

Ideal for patients with higher O2 needs in upper endoscopy, bronchoscopy, and other sedation procedures

  • Flexible oxygen titration from a minimum of 5 LPM to 15+ LPM
  • FiO2 delivery from 48% to 95% FiO23
  • Available in two sizes to accommodate adult patient types (adult and adult plus)

Oxy2Mask™* EtCO2 with Microstream™ Connector

Ideal for medical-surgical suites, the ER, and other patient care areas where procedural sedation is performed.

  • Flexible oxygen titration from 1 LPM to 15+ LPM
  • FiO2 delivery from 24% to 83% FiO2
  • Available in three sizes to accommodate all patient types (Adult, Adult Plus, and Kid)

Helping you better manage your team’s workflow

Better access

  • A 360° swivel adapter on both masks keeps tubing out of your way.
  • The Oxy2Pro™* has a large star-shaped oral window which provides ease of access to the patient airway, while still maintaining oxygenation and monitoring of EtCO2.

 

 

 

 

 

Better workflow

  • Both masks come pre-assembled as an all-in-one device to help you quickly get your patient connected.

 

 

 

 

Better airflow

Both EtCO2 masks feature a new triangular diffuser mushroom disc insert that improves FiO2 by refining the shape of the oxygen vortices and directing oxygen flow with accelerated velocity toward the patient’s nose and mouth.4–6

 

 

 

 

 

Patient safety proper fit

Get the right mask fit with different sizes available for both the open and closed masked designs.

  • Microstream™ monitoring should not be used as the sole basis for diagnosis or therapy and is intended only as an adjunct in patient assessment.
    Actual FiO2 will vary. Breath rate, depth of breathing, and distance of the diffuser cup from the face will affect performance.

  • TM* Oxy2Pro™* and Oxy2Mask™* are manufactured by Southmedic Inc.. and distributed by Medtronic.

  • † Closed masks require minimum 5 LPM O2 flow.

     

  • 1. SouthMedic Inc. A comparative study of FiO2 & EtCO2 measurement for a proposed Oxy2EtCOdiffuser insert & OM-2125-8 under simulated patient conditions. SMI R&D Report: PROJ 2312, 2021.

  • 2. HockmanS, GlembotT, NiebelK. Comparison of capnography derived respiratory rate alarm frequency using the SARA algorithm versus an established non-adaptiverespiratory rate alarm management algorithm in bariatric surgical patients. RespCare. 2009 open forum abstract. December 2009.

  • 3. Burke R, Puddicombe C. SMI First in Human analysis of Oxy2Pro™* FiO2 performance report. 2324-01; 2022.

  • 4. Burke R, Puddicombe C. SMI First in Human analysis of Oxy2Pro™* FiO2 performance report. 2324-01; 2022.

  • 5. Burke R, Puddicombe C. SMI First in Human analysis of Oxy2Mask™* EtCO2 FiO2 performance report. 2312-01; 2022.

  • 6. Piper D. End Tidal CO2 FiO2 measurements for the SMI mask PR2125 & POM™* mask with a Bronchoscope probe. Protocol 21-0061, Piper Medical Products, 2021.