Cardiac resynchronization therapy (CRT) is a proven treatment for selected patients with heart failure-induced conduction disturbances and ventricular dyssynchrony. When used in combination with stable, optimal medical therapy, CRT is designed to reduce symptoms and improve cardiac function by restoring the mechanical sequence of ventricular activation and contraction.
A high-energy, wireless device with features that help to ensure CRT.
Key features include:
For CRT-D devices, certain programming and device operations may not provide cardiac resynchronization. Changes in a patient's disease and/or medications may alter the efficacy of a device's programmed parameters.
Specifications | |
---|---|
Volume |
38 cc |
Size (H x W x D) |
69 x 51 x 15 mm |
Mass |
68 g |
A high-energy, wireless device with features that help to ensure CRT.
Key features include:
Changes in patient's disease and/or medications may alter the efficacy of a device's programmed parameters or related features.
Specifications | |
---|---|
Volume |
38 cc |
Size (H x W x D) |
69 x 51 x 15 mm |
Mass |
68 g |
Yu CM, Wang L, Chau E, et al. Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation. August 9,2005;112(6):841-848.
Vollmann D, Nägele H, Schauert P, et al. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure. Eur Heart J. August 2007;28(15):1835-1840.
Catanzariti D, Lunati M, Landolina M, et al. Monitoring intrathoracic impedance with an implantable defibrillator reduces hospitalizations in patients with heart failure. PACE. March 2008;32(3):363-370.
Perego GB, Landolina M, Vergara G, et al. Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization. J Interv Card Electrophysiol. December 2008;23(3):235-242.
Small RS, Wickemeyer W, Germany R, et al. Changes in intrathoracic impedance are associated with subsequent risk of hospitalizations for acute decompensated heart failure: clinical utility of implanted device monitoring without a patient alert. J Card Fail. August 2009;15(6):475-481.
Abraham WT. Superior performance of intrathoracic impedance-derived fluid index versus daily weight monitoring in heart failure patients. Results of the Fluid Accumulation Status Trial. Late Breaking Clinical Trials. J Card Fail. Vol. 15 No. 9 2009, p 813.
Whellan DJ, Ousdigian KT, Al-Khatib SM, et al. Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients with Heart Failure) study. J Am Coll Cardiol. April 27, 2010;55(17):1803-1810.
A high-energy, wireless device with proven shock reduction and features that help to ensure CRT.
Key features include:
Changes in patient's disease and/or medications may alter the efficacy of a device's programmed parameters or related features.
Specifications | |
---|---|
Volume |
38 cc |
Size (H x W x D) |
69 x 51 x 15 mm |
Mass |
68 g |
Pace/sense ports |
Three IS-1 bipolar (A, RV, LV) |
Defibrillation ports |
Two DF-1 (RV coil [HVB], SVC [HVX] |
External shield |
Titanium |
Radiopaque ID |
PUG |
Battery |
Lithium silver vanadium oxide |
Wathen MS, DeGroot PJ, Sweeney MO, et al, for the PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. October 26, 2004;110(17):2591-2596.
The world’s first device with OptiVol Fluid Status Monitoring provides proven cardiac resynchronization and ICD therapies.
Key features include:
Changes in a patient’s disease and/or medications may alter the efficacy of a device’s programmed parameters or related features.
Specifications | |
---|---|
Volume |
40 cc |
Size (H x W x D) |
73 x 51 x 15 mm |
Mass |
78 g |
Yu CM, Wang L, Chau E, et al. Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation. August 9,2005;112(6):841-848.
Vollmann D, Nägele H, Schauert P, et al. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure. Eur Heart J. August 2007;28(15):1835-1840.
Catanzariti D, Lunati M, Landolina M, et al. Monitoring intrathoracic impedance with an implantable defibrillator reduces hospitalizations in patients with heart failure. PACE. March 2008;32(3):363-370.
Perego GB, Landolina M, Vergara G, et al. Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization. J Interv Card Electrophysiol. December 2008;23(3):235-242.
Small RS, Wickemeyer W, Germany R, et al. Changes in intrathoracic impedance are associated with subsequent risk of hospitalizations for acute decompensated heart failure: clinical utility of implanted device monitoring without a patient alert. J Card Fail. August 2009;15(6):475-481.
Abraham WT. Superior performance of intrathoracic impedance-derived fluid index versus daily weight monitoring in heart failure patients. Results of the Fluid Accumulation Status Trial. Late Breaking Clinical Trials. J Card Fail. Vol. 15 No. 9 2009, p 813.
Whellan DJ, Ousdigian KT, Al-Khatib SM, et al. Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients with Heart Failure) study. J Am Coll Cardiol. April 27, 2010;55(17):1803-1810.
Patient-tailored CRT options for heart failure management along with ICD protection.
Key features include:
Changes in a patient’s disease and/or medications may alter the efficacy of a device’s programmed parameters or related features.
Mechanical Specifications | |
---|---|
Volume |
38 cc |
Size (H x W x D) |
73 x 51 x 14 mm |
Mass |
77 g |
Wathen MS, Sweeney MO, DeGroot PJ, et al. Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation. August 14, 2001;104:796-801.
Yu CM, Wang L, Chau E, et al. Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation. August 9,2005;112(6):841-848.
Vollmann D, Nägele H, Schauert P, et al. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure. Eur Heart J. August 2007;28(15):1835-1840.
Catanzariti D, Lunati M, Landolina M, et al. Monitoring intrathoracic impedance with an implantable defibrillator reduces hospitalizations in patients with heart failure. PACE. March 2008;32(3):363-370.
Perego GB, Landolina M, Vergara G, et al. Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization. J Interv Card Electrophysiol. December 2008;23(3):235-242.
Small RS, Wickemeyer W, Germany R, et al. Changes in intrathoracic impedance are associated with subsequent risk of hospitalizations for acute decompensated heart failure: clinical utility of implanted device monitoring without a patient alert. J Card Fail. August 2009;15(6):475-481.
Abraham WT. Superior performance of intrathoracic impedance-derived fluid index versus daily weight monitoring in heart failure patients. Results of the Fluid Accumulation Status Trial. Late Breaking Clinical Trials. J Card Fail. Vol.15 No. 9 2009, p 813.
Whellan DJ, Ousdigian KT, Al-Khatib SM, et al. Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients with Heart Failure) study. J Am Coll Cardiol. April 27, 2010;55(17):1803-1810.