| Usable length 80 cm | Usable length 130 cm | Balloon diameter (mm) | Balloon length (mm) | Recommended introducer sheath (Fr) | RBP (atm) |
|---|---|---|---|---|---|
| ADM040250080 | ADM040250130 | 4.0 | 250 | 5 | 14 |
| ADM040300080 | ADM040300130 | 4.0 | 300 | 5 | 14 |
| ADM050250080 | ADM050250130 | 5.0 | 250 | 5 | 14 |
| ADM050300080L | ADM050300130L | 5.0 | 300 | 5 | 14 |
| ADM060250080L | ADM060250130L | 6.0 | 250 | 5 | 12 |
| ADM060300080L | ADM060300130L | 6.0 | 300 | 5 | 12 |
| ADM070250080 | ADM070250130 | 7.0 | 250 | 6 | 12 |
Indications
The Admiral Xtreme™ PTA balloon dilation catheter is intended to dilate stenoses in the iliac, femoral, ilio-femoral, popliteal, infra-popliteal, and renal arteries, and for the treatment of obstructive lesions of native arteriovenous dialysis fistulae.
Contraindications
The Admiral™ Xtreme PTA Catheter is contraindicated for use in coronary arteries and supra-aortic vessels. The Admiral™ Xtreme PTA Catheter is contraindicated for cases where the guidewire cannot cross the target lesion.
Product details
Long balloon lengths
250 and 300 mm balloon lengths are available for single dilatation of long lesions
Proprietary technology prevents banana-shaped balloon
Coaxial dual-lumen shaft design
Strong pushability and kink resistance are combined with flexibility
Offers support for contralateral maneuvers
Large inflation lumen enables fast inflation and deflation
Low balloon profile
Shows good refolding behavior
Cross lesions with confidence
Hydrophilic coating
Facilitates crossing
Flexitec™ Xtreme balloon material
Balloon wall thickness is reduced
Flexitec™ offers resistance against scratching
Provides high rated burst pressure
Manuals and Technical Guides
Find this technical manual in the product labeling supplied with each device.
Specifications
| Type | Specification1 |
|---|---|
| Catheter design | Over-the-wire (OTW) |
| Balloon material | Flexitec™ Xtreme |
| Balloon coating | LFC Hydrophilic |
| Balloon marker | 2 swaged (zero profile) platinum iridium |
| Usable shaft lengths | 80 cm, 130 cm |
| Shaft diameter | 5 Fr–6 Fr |
| Maximum guidewire compatibility | 0.035" |
Ordering information
| Usable length 80 cm | Usable length 130 cm | Balloon diameter (mm) | Balloon length (mm) | Recommended introducer sheath (Fr) | RBP (atm) |
|---|---|---|---|---|---|
| SBI030020080 | SBI030020130 | 3 | 20 | 5 | 18 |
| SBI030040080 | SBI030040130 | 3 | 40 | 5 | 18 |
| SBI030080080 | SBI030080130 | 3 | 80 | 5 | 18 |
| SBI030120080 | SBI030120130 | 3 | 120 | 5 | 18 |
| SBI040020080 | SBI040020130 | 4 | 20 | 5 | 18 |
| SBI040040080 | SBI040040130 | 4 | 40 | 5 | 18 |
| SBI040060080 | SBI040060130 | 4 | 60 | 5 | 18 |
| SBI040080080 | SBI040080130 | 4 | 80 | 5 | 18 |
| SBI040120080 | SBI040120130 | 4 | 120 | 5 | 18 |
| SBI040150080 | SBI040150130 | 4 | 150 | 5 | 14 |
| SBI040200080 | SBI040200130 | 4 | 200 | 5 | 14 |
| SBI040250080 | SBI040250130 | 4 | 250 | 5 | 14 |
| SBI040300080 | SBI040300130 | 4 | 300 | 5 | 14 |
| SBI050020080 | SBI050020130 | 5 | 20 | 5 | 17 |
| SBI050040080 | SBI050040130 | 5 | 40 | 5 | 17 |
| SBI050060080 | SBI050060130 | 5 | 60 | 5 | 17 |
| SBI050080080 | SBI050080130 | 5 | 80 | 5 | 15 |
| SBI050120080 | SBI050120130 | 5 | 120 | 5 | 15 |
| SBI050150080 | SBI050150130 | 5 | 150 | 5 | 14 |
| SBI050200080 | SBI050200130 | 5 | 200 | 5 | 14 |
| SBI050250080 | SBI050250130 | 5 | 250 | 5 | 14 |
| SBI050300080 | SBI050300130 | 5 | 300 | 6 | 14 |
| SBI060020080 | SBI060020130 | 6 | 20 | 5 | 17 |
| SBI060040080 | SBI060040130 | 6 | 40 | 5 | 17 |
| SBI060060080 | SBI060060130 | 6 | 60 | 5 | 17 |
| SBI060080080 | SBI060080130 | 6 | 80 | 5 | 15 |
| SBI060120080 | SBI060120130 | 6 | 120 | 5 | 15 |
| SBI060150080 | SBI060150130 | 6 | 150 | 5 | 12 |
| SBI060200080 | SBI060200130 | 6 | 200 | 6 | 12 |
| SBI060250080 | SBI060250130 | 6 | 250 | 6 | 12 |
| SBI060300080 | SBI060300130 | 6 | 300 | 6 | 12 |
| SBI070020080 | SBI070020130 | 7 | 20 | 5 | 16 |
| SBI070040080 | SBI070040130 | 7 | 40 | 5 | 16 |
| SBI070060080 | SBI070060130 | 7 | 60 | 5 | 14 |
| SBI070080080 | SBI070080130 | 7 | 80 | 5 | 14 |
| SBI070120080 | SBI070120130 | 7 | 120 | 6 | 12 |
| SBI070150080 | SBI070150130 | 7 | 150 | 6 | 12 |
| SBI070200080 | SBI070200130 | 7 | 200 | 6 | 12 |
| SBI070250080 | SBI070250130 | 7 | 250 | 6 | 12 |
| SBI080020080 | SBI080020130 | 8 | 20 | 6 | 14 |
| SBI080040080 | SBI080040130 | 8 | 40 | 6 | 14 |
| SBI080060080 | SBI080060130 | 8 | 60 | 6 | 11 |
| SBI080080080 | SBI080080130 | 8 | 80 | 6 | 11 |
| SBI090020080 | SBI090020130 | 9 | 20 | 6 | 14 |
| SBI090040080 | SBI090040130 | 9 | 40 | 6 | 14 |
| SBI090060080 | SBI090060130 | 9 | 60 | 6 | 11 |
| SBI090080080 | SBI090080130 | 9 | 80 | 6 | 11 |
| SBI100020080 | SBI100020130 | 10 | 20 | 6 | 11 |
| SBI100040080 | SBI100040130 | 10 | 40 | 6 | 11 |
| SBI120020080 | SBI120020130 | 12 | 20 | 7 | 11 |
| SBI120040080 | SBI120040130 | 12 | 40 | 7 | 11 |
Similar products