Superficial vein
ClosureFast™ radiofrequency ablation (RFA) system
<p>The ClosureFast™ procedure uses radiofrequency energy to treat patients with superficial vein disease.</p>
Overview
Data are from ClosureFast™ 7F studies. ClosureFast™ 6F catheter is designed to provide the same outcomes as established by ClosureFast™ 7F catheter.
Catheter inserted
into vein
Controlled heat
collapses vein
Catheter withdrawn,
closing vein
Deliver lasting results with gap-free thermal ablation
The ClosureFast™ procedure features a patented overlap of 0.5 cm at each thermal treatment segment, eliminating gaps between segments ― for lasting vein closure.1,3
6F profile, 8 cm heating length
1. 8 cm ablation
2. 0.5 cm overlap
3. 8 cm ablation
Note: 3 cm (7F) heating length available for shorter segments.
Data are from ClosureFast™ 7F studies. ClosureFast™ 6F catheter is designed to provide the same outcomes as established by ClosureFast™ 7F catheter.
Indications
The ClosureFast™ radiofrequency ablation catheter is intended for endovascular coagulation of blood vessels in patients with superficial vein reflux.
ClosureFast™ radiofrequency ablation catheter
- The ClosureFast™ radiofrequency ablation catheter precisely heats an 8 cm vein segment (or 3 cm for shorter, refluxing vein lengths) in one 20-second interval.
- The heat provided by the catheter shrinks and collapses the target vein, creating a fibrotic seal and occluding the vessel.
ClosureFast™ radiofrequency stylet
- The ClosureRFS™ radiofrequency stylet is an intravascular ablation device specifically intended for the treatment of incompetent perforator and tributary veins.
- This minimally invasive outpatient procedure leaves minimal scarring at the puncture site and can be either the primary treatment or an adjunct treatment using the ClosureFast™ radiofrequency ablation catheter.
ClosureFast™ radiofrequency generator
- The ClosureRFG™ generator delivers radiofrequency energy to the ClosureFast™ radiofrequency ablation catheter and the ClosureRFS™ radiofrequency stylet for the effective treatment of CVI.
- The controlled feedback mechanism monitors intravascular heat parameters in real time to automatically regulate therapeutic power.
Adverse events may include hematoma, phlebitis, skin injury, nerve injury, thrombophlebitis, thrombosis, and/or pulmonary embolism.
Ordering information
ClosureFast™ system catheter (global region)
| Item number | CF6-8-60 | CF6-8-100 | CF7-3-60 | CF7-7-60 | CF7-7-100 |
|---|---|---|---|---|---|
| Introducer sheath (min. ID size) | 6 Fr (2.0 mm) | 6 Fr (2.0 mm) | 7 Fr (2.3 mm) | 7 Fr (2.3 mm) | 7 Fr (2.3 mm) |
| Insertable length (cm) | 60 | 100 | 60 | 60 | 100 |
| Heating element diameter (mm) | 2.0 | 2.0 | 2.3 | 2.3 | 2.3 |
| Heating element length (cm) | 8 | 8 | 3 | 7 | 7 |
| Maximum power setting (W) | 40 | 40 | 18 | 40 | 40 |
| Default target temperature setting (C) | 120 | 120 | 120 | 120 | 120 |
| Software version: RFG2 | 4.0.0 or higher | 4.0.0 or higher | 4.4.0 or higher | 4.0.0 or higher | 4.0.0 or higher |
| Software version: RFG3 | 1.11.0 or higher | 1.11.0 or higher | 1.11.0 or higher | 1.11.0 or higher | 1.11.0 or higher |
| Compatible guidewire (in) | 0.025 | 0.025 | 0.025 | 0.025 | 0.025 |
ClosureRFG™ generator (global region)
| Item number | Voltage | Height (cm / in) | Width (cm / in) | Depth (cm / in) | Weight (kg / lbs.) |
|---|---|---|---|---|---|
| RFG3 | Universal — 100-240 V | 26.7 / 10.5 | 34 / 13.4 | 17.3 / 6.8 | 6.8 / 15 maximum |
ClosureFast™ system accessories
| Item number | Description |
|---|---|
| CLFKITTP | Full procedure pack with tumescent tubing set |
| EU-CLF-KITAC-TP | Procedure pack — blue tray, introducer needle, long green needle, blue trolley wrap, ultrasound probe cover, introducer sheath, (3) ultrasound gel, guidewire, tumescent tubing set |
| EU-CPP-7F | Procedure pack including guidewire, tray, needle, tray wrap, probe cover, (2) rubber bands, (2) label trolley cover packs, patient label, introducer, aquasonic gel sachet, guidewire |
| 497847 | Micro introducer set — Argon branded, 7 Fr x 11 cm |
| 10100/30409 | Kimal tubing for tumescent pump — Nouvag DP20 or DP30 |
| 1501COV | Pedal for tumescent pump — Nouvag DP30 |
| 4180- | Nouvag pump DP30 without pedal |
| 4187 | Nouvag pump DP30 with pedal |
| 6022COV | Nouvag tubing set — quantity: pack of 10 |
Related products
TM* Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
† Compared to ClosureFast 7F catheter and Venclose catheter in bench testing.
‡ Bench test data on file at Medtronic. N = 15 Venclose catheters and 30 each ClosureFast 6F and 7F catheters. Bench tests may not be indicative of clinical performance.
- Proebstle TM, Alm BJ, Göckeritz O, et al. Five-year results from the prospective European multicentre cohort study on radiofrequency segmental thermal ablation for incompetent great saphenous veins. Br J Surg. February 2015;102(3):212–218.
- Almeida JI, Kaufman J, Göckeritz O, et al. Radiofrequency endovenous ClosureFAST versus laser ablation for the treatment of great saphenous reflux: A multicenter, single-blinded, randomized study (RECOVERY Study). J Vasc Interv Radiol. June 2009;20(6):752–759.
- ClosureFast and ClosureFast RFS Patents. Medtronic data on file, 2022.
- Morrison N, Gibson K, Vasquez M, Weiss R, Jones A. Five-year extension study of patients from a randomized clinical trial (VeClose) comparing cyanoacrylate closure versus radiofrequency ablation for the treatment of incompetent great saphenous veins. J Vasc Surg Venous Lymphat Disord. November 2020;8(6):978–989.
- ClosureFast Procedures. Medtronic data on file, 2024.
- Medtronic ClosureFast Procedure Publications. Medtronic data on file, 2022.