Reflux testing systems

Digitrapper™ pH-Z testing system

<p>The Digitrapper™ pH-Z testing system monitors extra-esophageal symptoms and differentiates between reflux and non-reflux events.</p>

Features



Explore the components and features of our Digitrapper™ reflux testing system.

A product image of the Digitrapper™ pH-Z testing system

Digitrapper™ recorder

The Digitrapper™ recorder with combined pH and impedance provides total reflux monitoring, allowing you to differentiate acid and non-acid reflux in patients with an array of upper GI symptoms.1

Dual capability: pH-impedance or pH only

  • Compact size and lightweight (150 grams)
  • Direct data upload with USB cable
  • Easy to clean protective carrying case
Digitrapper™ reflux catheters

Digitrapper™ reflux catheters

Digitrapper™ reflux catheters used for pH and impedance monitoring.

  • Many configurations of pH and pH-impedance catheters4
  • Different diameters available (4.7 and 6.0 FR)4
  • Internal reference4
  • Antimony sensor technology4
  • Latex-free4

Digitrapper™ reflux testing system technology 

Know reflux symptoms with catheter-based pH and impedance testing.

The Digitrapper™ reflux testing system enables a thorough evaluation of acid reflux symptoms, helping physicians to improve management of GERD patients.3

  • Enables the detection of reflux events and measures their duration and acid content4
  • Combines pH and impedance testing for patients

Ordering information

Item number Description Units per box
800004 Digitrapper™ recorder pH-Z 1
900003 VersaFlex-Z - ZNID15+8R. 2pH/6Z (includes gastric pH measurement), disposable pH + impedance catheter, internal reference, pH channels at -15 cm (distal) and 0 cm (proximal), 8 impedance rings at -3, -1, 1, 3, 5, 9, 11, and 13 cm from proximal pH sensor 1
957900 VersaFlex VNIS+US catheter - VNIS+US disposable bifurcated pH catheters, internal reference, catheter 1 and 2 both single channel, (4.7 Fr), 10/pkg 1

Related links

Capsule Endoscopy System Tech Support Promo Box

Technical support

Get technical support for all endoscopy products.

Email us
Phone UK & IE
: +44 1923 201860

The Digitrapper pH-Z System is intended to record, store, view, and analyze esophageal and gastric pH data (and optionally, impedance levels) to diagnose reflux disorders. potential adverse events associated with the use of this system and catheter insertion into the nasal passage include but are not limited to:

  • Discomfort, nasal pain, minor bleeding, runny nose, throat discomfort, irregular heartbeat with dizziness, and perforation. 
  • In rare instances, the catheter may be misdirected into the trachea causing coughing or choking, the catheter may curl during intubation, and catheter position may move during the procedure.

Medical, endoscopic, or surgical intervention may be necessary to address any of these complications, should they occur. The system is not compatible for use in an MRI magnetic field.

  1. Sifrim D, Castell D, Dent J, Kahrilas PJ. Gastro-oesophageal reflux monitoring: review and consensus report on detection and definitions of acid, non-acid, and gas reflux. Gut. 2004;53(7):1024–1031. 
  2. Garrean CP, Zhang Q, Gonsalves N, Hirano I. Acid reflux detection and symptom — Reflux Association using 4-day wireless pH recording combining 48-hour periods off and on PPI therapy. Am J Gastroenterol. 2008;103:1631–1637.