Open instruments

LigaSure Impact™ sealer-divider with nano-coating

<p>The LigaSure Impact™ is a multifunctional tissue fusion system for open procedures, with an integrated cutting mechanism and a 36mm long jaw curved 14 degrees.<sup>1</sup></p>

Features

Vessel sealing technology you can count on  

The LigaSure Impact™ sealer-divider can grasp, seal, and cut tissue independently — or you can perform all three in one step. The device’s large jaws also:

  • Enable fast transection2

  • Minimize the need for multiple activations‡,3

  • Facilitate procedural efficiency2

But the latest innovation comes from the nonstick coating on the LigaSure Impact™ device jaws. Compared to our legacy device, the nonstick coating:

  • Reduces sticking by 67%4

  • Reduces eschar buildup by 50%§,5

  • Results in fewer cleanings,◊,5

  • Makes cleaning more efficient◊,¶,5

The end result is a smoother procedure — for surgeons and patients. 

Comfortable feel in your hands

The LigaSure Impact™ device is lightweight and comfortable to use, and the activation button is ergonomically positioned.2 It’s designed to optimize performance across a range of specialties, including:

  • Urology

  • Colorectal

  • General surgery

  • Gynecology

The jaws of the LigaSure Impact™ device also facilitate access because they follow the curve of the stomach and uterus.#,2

Enhancing surgical performance, efficiently

Learn more about the nonstick coating technologies we added to energy-based devices like the LigaSure™ blunt tip device.

Specifications

Physical characteristics 
General Sterile, single use
Shaft length (cm) 18 cm 
Shaft diameter (mm) 13.5  (oval)
Shaft rotation 180 degrees
Jaw design Curved, 14 degrees
Seal plate length (mm) 36 
Cut length (mm) 34 
Foot switching Yes
Generator compatibility Valleylab™ FT10 energy platform, Valleylab™ LS10 generator

 

Ordering information

Item number Description Units per box
LF4418 LigaSure Impact™ open sealer-divider with nano-coating 6

TM*  Third-party brands are trademarks of their respective owners.

†  Cleaning effectiveness assessed using porcine uterine tissue, a wet guaze cleaning fixture, and optical imaging analysis after each of 2 cleaning cycles.

‡Bench testing model used to statistically evaluate burst pressure of renal arteries. Evidence: Testing performed on fresh porcine kidneys, using LigaSure devices: LF1212A (p=0.2898); LF1637 (p=0.6352); LF4318 (p=0.8961); and LS1037 (p=0.9528).

§ Eschar build-up assessed using optical imaging analysis after 60 seal and divide cycles.

◊Using a wet gauze cleaning fixture and optical imaging analysis. Cleaning effectiveness assessed after each of two cleaning cycles.

¶ Cleaning effectiveness assessed using porcine uterine tissue, a wet guaze cleaning fixture, and optical imaging analysis after each of 2 cleaning cycles.

#12 out of 12 surgeons evaluated agreed.

  1. LigaSure Impact Curved Large Jaw, Open Sealer/Divider Nano-coated Indications for Use.
  2. Chivukula, S.R., Lammers, S. & Wagner, J. Assessing organic material on single-use vessel sealing devices: a comparative study of reprocessed and new LigaSure™ devices. Surg Endosc (2020). https://doi.org/10.1007/s00464-020-07969-8

  1. Based on internal test report RE00052321, Lig-40 marketing report surgeon evaluation of LigaSure Impact™ LF4418: independent surgeon feedback collected during porcine labs. June 21–22, 2016.
  2. Based on internal test report RE00034755, LF4418 design verification report, Benchtop testing using porcine abdominal aorta, mesentery, and renal arteries with average (lbs.) sticking force. February 24, 2016 and March 25, 2016.
  3. Based on Covidien ex-vivo renal burst pressure report R0064457: Verification report LigaSure™ renal bench burst pressure evaluation of the Valleylab™ FT10." May 3, 2015; 
  4. Based on internal test report RE00057355, Lig-40 report product claim LF4418, Benchtop testing using porcine uterine tissue. Eschar buildup assessed using optical imaging analysis after 20, 40, and 60 seal and divide cycles. July 29, 2016.