The first-of-its-kind SenSight™ Directional Lead System

The benefits of directionality plus the power of sensing.

 

Contact Us

SENSIGHTTM DIRECTIONAL LEADS

With your collaboration and insights, we’ve completely redesigned every component of our DBS system – including the lead, the burr hole device, the extension, and everything in between. It's the first and only sensing-enabled SenSightTM directional lead.

GO BEYOND.

Navigate the power of sensing with the world's most advanced and innovative DBS system.

Download the brochure

1. 1-3-3-1 electrode configuration to more precisely direct the stimulation

2. 1.5mm and 0.5mm electrode spacing options to suit various targeting and patient needs

3. Completely insulated orientation markers to guide directional programming 

need

Realise the full capability of the PerceptTM PC Neurostimulator

Built with proprietary materials, components, and processes, the SenSight™ directional lead and Sensight™ Extension work seamlessly with the Percept™ PC Neurostimulator to enhance detection of local field potentials (LFPs), which are 1 million times smaller than DBS stimulation pulses.1

Desktop Collage for SureTune

SURETUNE™ 4 SOFTWARE: THE BRIDGE BETWEEN THE OPERATING ROOM AND PROGRAMMING  

Our visualisation tool uses imaging as a common language to provide a meaningful transfer of data from the implanting team to the patient management team. Patient-specific anatomy and lead location and orientation information can be pulled into the DBS Clinician Programmer.

With sensing, directionality and visual programming you can access data-driven insights to tailor therapy with confidence.

Discuss SensightTM directional leads with our product experts

*Indicates Required Field

Your information will be processed and protected in accordance with our privacy statement

Selecting “no” to marketing emails above will not affect your other email selections, and a Medtronic representative will still reach out via email, if selected. Your personal data will used to manage your relationship with Medtronic, and, if you consent, to provide you with relevant email updates based on your user preferences. You can opt-out of receiving such emails at any time by clicking the unsubscribe link in the relevant email. Medtronic may use pixels and other technologies in emails to gather statistics around email opening and clicks, to help us improve our communications and to provide you with relevant content. For more information, see the Medtronic privacy notice.

You can always change your preferences or update your personal details by visiting the Preference center.

See the Preference center

1

Neumann WJ, Staub F, Horn A, et al. Deep brain recordings using an implanted pulse generator in Parkinson’s disease. Neuromodulation. 2016;19(1):20-24

2

Leakage requirement Doc: NDHF1513-145311. Patent: 7,83,365 (24 Aug, 2010)

*

The sensing feature of the Percept™ PC system is intended for use in patients receiving DBS where chronically recorded bioelectric data may provide useful, objective information regarding patient clinical status. Signal may not be present or measurable in all patients. Clinical benefits of brain sensing have not been established.

Brief Statement
See the device manual for detailed information regarding the instructions for use, the implant procedure, indications, contraindications, warnings, precautions, and potential adverse events , If using an MRI SureScan® device, see the MRI SureScan® technical manual before performing an MRI. For further information, contact your local Medtronic representative and/or consult the Medtronic website at medtronic.eu.