VersaOne™ Optical Trocar

Product Details

The advantages of the optical trocar include:

  • Smoother insertion – “dolphin nose tip” facilitates smoother insertion for easier trocar placement vs. Applied Medical([FOOTNOTE=Based on internal test report#2143-114, Applies to Medtronic 12 mm trocars, when compared to Applied Kii™* (12 mm trocar, Z-thread cannula). March 2013.],[ANCHOR=],[LINK=])
  • Port fixation and security – advanced fixation ribs keep cannula from moving during procedures1
  • Visualization – excellent visualization delivers clear tissue identification upon insertion
  • Interlocking snap feature to secure obturator during insertion
Order Information

Order Information
Order Code Description Size Length Unit of Measure Quantity
ONB5STF VersaOne™ Optical Trocar with Fixation Cannula 5 mm 100 mm Box 6
ONB5SHF VersaOne™ Optical Trocar with Fixation Cannula 5 mm 70 mm Box 6
ONB5LGF VersaOne™ Optical Trocar with Fixation Cannula
5 mm 150 mm
Box 6
ONB5STF2C VersaOne™ Optical Trocar with Dual Fixation Cannula
5 mm 100 mm Box 6
ONB11STF
VersaOne™ Optical Trocar with Fixation Cannula
11 mm 100 mm
Box 6
ONB11LGF VersaOne™ Optical Trocar with Fixation Cannula
11 mm 150 mm
Box 6
ONB12STF
VersaOne™ Optical Trocar with Fixation Cannula
12 mm 100 mm
Box 6
ONB12STS VersaOne™ Optical Trocar with Smooth Cannula
12 mm 100 mm
Box 6
ONB12SHF VersaOne™ Optical Trocar with Fixation Cannula
12 mm 70 mm
Box 6
ONB12LGF VersaOne™ Optical Trocar with Fixation Cannula
12 mm 150 mm
Box 6
ONB15STF VersaOne™ Optical Trocar with Fixation Cannula
15 mm 100 mm
Box 6

VersaOne™ Bladed Trocar

Product Details

The advantages of the bladed trocar include a:

  • Safety lock to inform user when blade is exposed
  • Parabolic shield designed to retract over the blade once in the peritoneal cavity
  • Bladed design that is sharpened on both sides to divide tissue cleanly and precisely with control upon insertion through the abdominal wall
  • Low profile ergonomic designed obturator to provide control and comfort during insertion([FOOTNOTE=Based on internal VOC report, Project Eichler and Lieberman research. May 2013.],[ANCHOR=],[LINK=])
Order Information

Order Information
Order Code Description Size Length Unit of Measure Quantity
B5STF VersaOne™ Bladed Trocar with Fixation Cannula 5 mm 100 mm Box 6
B5STS VersaOne™ Bladed Trocar with Smooth Cannula
5 mm 100 mm
Box 6
B5SHF VersaOne™ Bladed Trocar with Fixation Cannula 5 mm 70 mm Box 6
B5SHS VersaOne™ Bladed Trocar with Smooth Cannula
5 mm 70 mm Box 6
B11STF
VersaOne™ Bladed Trocar with Fixation Cannula 11 mm 100 mm
Box 6
B11STS VersaOne™ Bladed Trocar with Smooth Cannula
11 mm 100 mm
Box 6
B12STF
VersaOne™ Bladed Trocar with Fixation Cannula 12 mm 100 mm
Box 6
B12STS VersaOne™ Bladed Trocar with Smooth Cannula
12 mm 100 mm
Box 6
B12LGF VersaOne™ Bladed Trocar with Fixation Cannula
12 mm 150 mm
Box 6
B12LGS VersaOne™ Bladed Trocar with Smooth Cannula
12 mm 150 mm
Box 6

VersaOne™ Blunt Trocar

Product Details

The advantages of the blunt trocar include:

  • Low profile hub to accommodate a variety of users
  • Finger grip for easy repositioning of the threaded anchor on the shaft of the cannula
  • Two suturing wings to secure suture tie down
  • Threaded anchor to ensure trocar placement
Order Information

Order Information
Order Code Description Size Length Unit of Measure Quantity
BPT12STS VersaOne Blunt Trocar with Threaded Anchor 12 mm 100 mm Box 3

VersaOne™ Bladeless Trocar

Product Details

The advantages of the bladeless trocar include:

  • Unique “dolphin nose” tip to facilitate smoother insertion for easier trocar placement1
  • Advanced fixation ribs keep cannula from moving during procedures1
  • Ergonomic design to provide control and comfort during laparoscopic procedures2
Order Information

Order Information
Order Code Description Size Length Unit of Measure Quantity
NONB5STF VersaOne™ Bladeless Trocar with Fixation Cannula 5 mm 100 mm Box 6
NONB5SHF VersaOne™ Bladeless Trocar with Fixation Cannula 5 mm 70 mm Box 6
NONB5LGF VersaOne™ Bladeless Trocar with Fixation Cannula
5 mm 150 mm
Box 6
NONB8STF VersaOne™ Bladeless Trocar with Fixation Cannula
8 mm 100 mm Box 6
NONB11STF
VersaOne™ Bladeless Trocar with Fixation Cannula 11 mm 100 mm
Box 6
NONB12STF
VersaOne™ Bladeless Trocar with Fixation Cannula 12 mm 100 mm
Box 6
NONB12STS VersaOne™ Bladeless Trocar with Smooth Cannula
12 mm 100 mm Box 6
NONB12SHF VersaOne™ Bladeless Trocar with Fixation Cannula 12 mm 70 mm Box 6
NONB12LGF VersaOne™ Bladeless Trocar with Fixation Cannula
12 mm 150 mm
Box 6
NONB15STF VersaOne™ Bladeless Trocar with Fixation Cannula
15 mm 100 mm Box 6
NONB15LGF VersaOne™ Bladeless Trocar with Fixation Cannula
15 mm 150 mm Box 6

VersaOne™ Universal Cannula

Product Details

Our VersaOne™ trocar platform features a universal cannula designed to fit with all obturators, giving surgeons flexibility based on the patient and procedure. The design includes:

  • Funneled entry, enhanced seal to allow a smooth instrument exchange1
  • Advanced fixation ribs to securely keep cannula from moving during surgical procedure1
  • Release button for specimen removal
  • Clear cannula for visualization
  • Increased inner diameter to accommodate standard
    12 mm laparoscopic instruments
  • Beveled cannula edge
  • Low profile seal housing for maneuverability in tight spaces
  • Low profile three-way stopcock for controlled insufflation and desufflation
Order Information

Order Information
Order Code Description Size Length Unit of Measure Quantity
UNVCA5STF VersaOne™ Universal  Fixation Cannula
5 mm 100 mm Box 6
UNVCA5SHF VersaOne™ Universal Fixation Cannula 5 mm 70 mm
Box 6
UNVCA5LGF VersaOne™ Universal Fixation Cannula
5 mm 150 mm
Box 6
UNVCA11STF VersaOne™ Universal Fixation Cannula
11 mm 100 mm Box 6
UNVCA12STF VersaOne™ Universal Fixation Cannula
12 mm 100 mm Box 6
UNVCA12STS VersaOne™ Universal Smooth Cannula
12 mm 100 mm Box 6
UNVCA12LGF VersaOne™ Universal Fixation Cannula
12 mm 150 mm
Box 6

VersaOne™ Fascial Closure System

Product Details

Consistent port-site closures without removing the port([FOOTNOTE=Based on internal validation report #RE00098009 Rev A, DoubleTime VersaOne™ fascial closure system Miami lab VOC report: 13 out of 16 surgeons surveyed agreed. March 28, 2017.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal validation report #RE00062341 Rev A, Summative usability of project DoubleTime VersaOne™ fascial closure system. Aug. 24–25, 2016.],[ANCHOR=],[LINK=])

The VersaOne™ fascial closure system is a unique all-in-one3 solution that serves as a trocar and a fascial closure device to deliver:

  • Consistent port-site closure3
  • Added procedural efficiency3,†
  • Ease of use3

Overview

Outstanding visualization. Secure placement.

Introducing the VersaOne™ access system, a universal trocar platform that gives you the performance, choice, and peace of mind in one complete solution.

A universal cannula

A clear sleeve compatible with all VersaOne™ access system trocars, provides visualization for an informed entry. It features a durable seal system, designed to allow for repeated instrument exchanges, and an advanced ribbed fixation that offers port security from start to finish.([FOOTNOTE=Based on internal test report#2143-123. Applies to Medtronic 12 mm trocars, when compared to the Versaport™ Bladeless 12 mm trocar. March 2013.],[ANCHOR=],[LINK=]),†

A full range of options

Our product families meet all your needs, with a complete range of trocars including a bladeless, blunt, optical, and bladed trocar.

  • †Images recorded on March 14, 2013, as part of a trocar clarity evaluation in an inanimate abdominal model; images representative of evaluation results.

  • ‡As compared to Medtronic legacy trocars.

  • §Based on cadaver usability lab with 16 surgeons (13 of 16 surgeons agreed). The two devices are: a standard trocar and a fascial closure system. Preclinical results may not correlate with clinical performance in humans.

  • ΩBased on usability lab with 16 surgeons (16 of 16 surgeons agreed). Preclinical results may not correlate with clinical performance in humans.

  • ††Based on usability lab with 16 surgeons (13 of 16 surgeons agreed). Preclinical results may not correlate with clinical performance in humans.