Tissue varies but your staple lines shouldn’t. That's why the Signia™ stapling system adjusts firing speed based on force feedback when clamped and during firing.3,4,* The result: consistent staple lines — across variable tissue.([FOOTNOTE=Based on internal test report #R2146-173-0, ASA verification testing with slow speed force limit evaluation. 2015.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #R2146-151-0, Powered stapling firing speed DOE analysis and ASA parameters. 2015.],[ANCHOR=],[LINK=]),*
Plus, the Signia™ system gives you the precision of fully powered rotation, articulation, and firing([FOOTNOTE=Based on internal test report #RE00024826 rev D, Signia™ stapling system summative usability report. September 2016.],[ANCHOR=],[LINK=]),§ with one hand.5,†
Fewer malformed staples.1,* Stronger staple lines.([FOOTNOTE=Based on internal test report #RE00147607, 4.5 mm round staple pull-apart analysis report.],[ANCHOR=],[LINK=]),*
The Signia™ stapler is compatible with our existing reload portfolio featuring the proven performance of Tri-Staple™ technology. It delivers:
| Order Code | Description | Unit of Measure | Quantity |
|---|---|---|---|
| SIGPHANDLE | Signia™ Power Handle | Each | 1 |
| SIGPSHELL | Signia™ Power Control Shell | Each | 1 |
| SIGADAPTSTND | Signia™ Linear Adapter | Each | 1 |
| SIGADAPTXL | Signia™ Linear Adapter XL | Each | 1 |
| SIGADAPTSHORT | Signia™ Linear Adapter Short | Each | 1 |
| SIGSBCHGR | Signia™ Single-Bay Charger | Each | 1 |
| SIGRIG | Signia™ Reusable Insertion Guide | Each | 1 |
| SIGMRET | Signia™ Manual Retraction Tool | Each | 1 |
| SIGTRAY | Signia™ Sterilization Tray | Each | 1 |
| SIGPCORD1 | Signia™ Power Cord 1 - US | Each | 1 |
| SIGPCORD6 | Signia™ Power Cord 6 - JA | Each | 1 |
The Signia™ stapler adapts to tissue variability3,4,* and lets you know — before you fire — with visual and audible feedback from the handle. This is made possible by Adaptive Firing™ technology and real-time feedback.3,4,*
When you clamp on tissue, the Signia™ stapler:
Information about stapling conditions3,4,* — and more consistent staple lines3,4,*
The Signia™ stapler's continuous clamp force measurements — displayed on the handle in real time during a procedure — give you information about stapling conditions.3,4,* Higher clamp force measurements may indicate thicker tissues and more challenging tissue applications.3,4,*
The Signia™ stapler adapts to these changing surgical conditions by appropriately adjusting firing speed based on force measurements. As a result, you get optimized staple formation — with more consistent staple lines.3,4,([FOOTNOTE=Based on internal report #RE00218740, Signia™ stapling adaptive firing technology data calculations and references. Aug. 7, 2019.],[ANCHOR=],[LINK=]),*,‡
* Preclinical results may not correlate with clinical performance in humans.
† 38 out of 38 surgeons surveyed agreed.
‡ Bench test results may not necessarily be indicative of clinical performance.
§ Compared to manual and fixed-speed powered staplers.