90 cm catheter length | 150 cm catheter length | Balloon Diameter (mm) | Balloon length (mm) | Nominal pressure (atm) | Rated burst pressure (atm) | Recommended introducer sheath (Fr) |
AB14W015020090 | AB14W015020150 | 1.5 | 20 | 8 | 14 | 4 |
AB14W015040090 | AB14W015040150 | 1.5 | 40 | 8 | 14 | 4 |
AB14W020020090 | AB14W020020150 | 2.0 | 20 | 8 | 14 | 4 |
AB14W020040090 | AB14W020040150 | 2.0 | 40 | 8 | 14 | 4 |
AB14W020060090 | AB14W020060150 | 2.0 | 60 | 8 | 14 | 4 |
AB14W020080090 | AB14W020080150 | 2.0 | 80 | 8 | 14 | 4 |
AB14W020100090 | AB14W020100150 | 2.0 | 100 | 8 | 14 | 4 |
AB14W020120090 | AB14W020120150 | 2.0 | 120 | 8 | 14 | 4 |
AB14W020150090 | AB14W020150150 | 2.0 | 150 | 8 | 14 | 4 |
AB14W020210090 | AB14W020210150 | 2.0 (proximal) / 1.5 (distal) | 210 | 8 | 14 | 4 |
AB14W025020090 | AB14W025020150 | 2.5 | 20 | 8 | 14 | 4 |
AB14W025040090 | AB14W025040150 | 2.5 | 40 | 8 | 14 | 4 |
AB14W025060090 | AB14W025060150 | 2.5 | 60 | 8 | 14 | 4 |
AB14W025080090 | AB14W025080150 | 2.5 | 80 | 8 | 14 | 4 |
AB14W025100090 | AB14W025100150 | 2.5 | 100 | 8 | 14 | 4 |
AB14W025120090 | AB14W025120150 | 2.5 | 120 | 8 | 14 | 4 |
AB14W025150090 | AB14W025150150 | 2.5 | 150 | 8 | 14 | 4 |
AB14W025210090 | AB14W025210150 | 2.5 (proximal) / 2.0 (distal) | 210 | 8 | 14 | 4 |
AB14W030020090 | AB14W030020150 | 3.0 | 20 | 8 | 14 | 4 |
AB14W030040090 | AB14W030040150 | 3.0 | 40 | 8 | 14 | 4 |
AB14W030060090 | AB14W030060150 | 3.0 | 60 | 8 | 14 | 4 |
AB14W030080090 | AB14W030080150 | 3.0 | 80 | 8 | 14 | 4 |
AB14W030100090 | AB14W030100150 | 3.0 | 100 | 8 | 14 | 4 |
AB14W030120090 | AB14W030120150 | 3.0 | 120 | 8 | 14 | 4 |
AB14W030150090 | AB14W030150150 | 3.0 | 150 | 8 | 14 | 4 |
AB14W030210090 | AB14W030210150 | 3.0 (proximal) / 2.5 (distal) | 210 | 8 | 14 | 4 |
AB14W035020090 | AB14W035020150 | 3.5 | 20 | 8 | 14 | 4 |
AB14W035040090 | AB14W035040150 | 3.5 | 40 | 8 | 14 | 4 |
AB14W035060090 | AB14W035060150 | 3.5 | 60 | 8 | 14 | 4 |
AB14W035080090 | AB14W035080150 | 3.5 | 80 | 8 | 14 | 4 |
AB14W035100090 | AB14W035100150 | 3.5 | 100 | 8 | 14 | 4 |
AB14W035120090 | AB14W035120150 | 3.5 | 120 | 8 | 14 | 4 |
AB14W035150090 | AB14W035150150 | 3.5 | 150 | 8 | 14 | 4 |
AB14W035210090 | AB14W035210150 | 3.5 (proximal) / 3.0 (distal) | 210 | 8 | 14 | 4 |
AB14W040020090 | AB14W040020150 | 4.0 | 20 | 8 | 14 | 4 |
AB14W040040090 | AB14W040040150 | 4.0 | 40 | 8 | 14 | 4 |
AB14W040060090 | AB14W040060150 | 4.0 | 60 | 8 | 14 | 4 |
AB14W040080090 | AB14W040080150 | 4.0 | 80 | 8 | 14 | 4 |
AB14W040100090 | AB14W040100150 | 4.0 | 100 | 8 | 14 | 4 |
AB14W040120090 | AB14W040120150 | 4.0 | 120 | 8 | 14 | 4 |
AB14W040150090 | AB14W040150150 | 4.0 | 150 | 8 | 14 | 4 |
AB14W040210090 | AB14W040210150 | 4.0 (proximal) / 3.5 (distal) | 210 | 8 | 14 | 4 |
AB14W050020090 | AB14W050020150 | 5.0 | 20 | 8 | 14 | 5 |
AB14W050040090 | AB14W050040150 | 5.0 | 40 | 8 | 14 | 5 |
AB14W050060090 | AB14W050060150 | 5.0 | 60 | 8 | 14 | 5 |
AB14W050080090 | AB14W050080150 | 5.0 | 80 | 8 | 14 | 5 |
AB14W050100090 | AB14W050100150 | 5.0 | 100 | 8 | 14 | 5 |
AB14W050120090 | AB14W050120150 | 5.0 | 120 | 8 | 14 | 5 |
AB14W050150090 | AB14W050150150 | 5.0 | 150 | 8 | 14 | 5 |
AB14W050200090 | AB14W050200150 | 5.0 | 200 | 8 | 14 | 5 |
AB14W060020090 | AB14W060020150 | 6.0 | 20 | 8 | 14 | 5 |
AB14W060040090 | AB14W060040150 | 6.0 | 40 | 8 | 14 | 5 |
AB14W060060090 | AB14W060060150 | 6.0 | 60 | 8 | 14 | 5 |
AB14W060080090 | AB14W060080150 | 6.0 | 80 | 8 | 14 | 5 |
AB14W060100090 | AB14W060100150 | 6.0 | 100 | 8 | 14 | 5 |
AB14W060120090 | AB14W060120150 | 6.0 | 120 | 8 | 14 | 5 |
AB14W060150090 | AB14W060150150 | 6.0 | 150 | 8 | 14 | 5 |
AB14W060200090 | AB14W060200150 | 6.0 | 200 | 8 | 14 | 6 |
Standard PTA balloons
NanoCross™ Elite PTA catheter
<p>The NanoCross™ Elite PTA Catheter's robust shaft design makes it easier to access, reach and treat distal lesions in the lower leg.</p>
Features
Pushability that takes you deeper into the anatomy and across difficult lesions
Seamless design results in efficient energy transfer with no hang-up points
Robust shaft design offers buckle-resistant pushability and delivery across the length of the catheter
Smooth, tapered tip designed to easily navigate turns in tortuous anatomy.
Low crossing profile enables successful crossing of lesions
Tighter pleat fold reduces the crossing profile for easier access to smaller, tighter, more distal regions
Energy transfer
The NanoCross™ Elite PTA catheter (top) transfers energy efficiently through a seamless design with no hang-up points. A typical PTA catheter (bottom) has hang-up points that may cause energy dispersal.1
Design of the NanoCross™ Elite PTA catheter
- Robust shaft design for kink-resistant pushability and delivery across the length of the catheter
- Smooth, tapered tip designed to easily navigate turns in tortuous anatomy
- Low crossing profile enables successful crossing of lesions
- Tighter pleat fold reduces the crossing profile for easier access to smaller, tighter, distal regions
Ordering information
Similar products
-
Admiral Xtreme™ PTA balloon catheter
The Admiral Xtreme™ PTA balloon catheter is available in 250 and 300 mm balloon lengths.
-
Amphirion™ Deep PTA balloon catheter
The Amphirion™ Deep PTA balloon catheter is ideally suited for treating lesions below the ankle and into the foot.
-
EverCross™ PTA catheter
The EverCross™ PTA catheter is used to treat peripheral arterial disease (PAD) in many vessel sizes and lesion types.
-
Fortrex™ HP PTA balloon catheter
The Fortrex™ HP PTA balloon catheter balances push and track to deliver high pressure, targeted treatment to challenging AV access lesions.
-
Pacific™ Plus PTA catheter
The Pacific™ Plus PTA catheter features a broad size matrix and a low profile to handle cases above the knee (ATK) or below the knee (BTK).
-
RapidCross™ RX PTA catheter
The RapidCross™ rapid exchange (RX) percutaneous transluminal angioplasty (PTA) catheter is used in treating distal lesions in the small vessels below the knee.
- Design validation test data on file with Medtronic.