Capnography monitoring

Microstream™ Advance filter line portfolio

<p>Microstream™ Advance filter lines are available in sizes to accommodate neonate to adult patients and can be used in virtually all clinical settings.</p>

Features

  • Nonintubated filter line options feature proprietary oral/nasal and nasal-only CO2 sampling and an innovative supplemental oxygen delivery system.
  • Orange connectors designate short-term use and yellow connectors designate use for extended duration.
  • Intubated and nonintubated options for short-term and long-term monitoring
  • Uni-junction™ technology, designed for effective sampling with and without oxygen delivery, from both nares and the mouth, even at low tidal volumes1
  • Oral scoop design has wide surface area to provide breath capture even in the presence of shallow breathing2
  • Oxygen flows from holes in front of nasal prongs and improves humidity of O2
  • Soft tubing and neutral scent help provide improved patient compliance3
  • Low flow 50 mL per minute sample rate, recommended for neonatal sampling2

Ordering information

Microstream™ Advance filter lines for nonintubated patients — long-term use

Item number Size Description Configuration Length Length (ft) Length (cm) Units per box
MVAOH Adult Oral/nasal O2 tubing female connector Standard 6.5 200 25
MVAOH100U Adult Oral/nasal O2 tubing female connector Standard 6.5 200 100
MVAOHL Adult Oral/nasal O2 tubing female connector Long 13 400 25
MVPOH Pediatric Oral/nasal O2 tubing female connector Standard 6.5 200 25
MVPOHL Pediatric Oral/nasal O2 tubing female connector Long 13 400 25
MVANH Adult Nasal No O2 delivery Standard 6.5 200 25
MVANOH Adult Nasal O2 tubing female connector Standard 6.5 200 25
MVPNOH Pediatric Nasal O2 tubing female connector Standard 6.5 200 25
MVINH Neonatal Nasal No O2 delivery Standard 6.5 200 25
MVINOH Neonatal Nasal O2 tubing female connector Medium 9.8 300 25
MVINHL Neonatal Nasal No O2 delivery Long 13 400 25

Microstream™ Advance filter lines for nonintubated patients — short-term use

Item number Size Description Configuration Length Length (ft) Length (cm) Units per box
MVA Adult Oral/nasal O2 male connector Standard 6.5 200 25
MVA100U Adult Oral/nasal O2 male connector Standard 6.5 200 100
MVAL Adult Oral/nasal O2 male connector Long 13 400 25
MVAL100U Adult Oral/nasal O2 male connector Long 13 400 100
MVAO Adult Oral/nasal O2 tubing female connector Standard 6.5 200 25
MVAO100U Adult Oral/nasal O2 tubing female connector Standard 6.5 200 100
MVAOL Adult Oral/nasal O2 tubing female connector Long 13 400 25
MVAOL100U Adult Oral/nasal O2 tubing female connector Long 13 400 100
MVP Pediatric Oral/nasal No O2 delivery Standard 6.5 200 25
MVPO Pediatric Oral/nasal O2 tubing female connector Standard 6.5 200 25
MVPOL Pediatric Oral/nasal O2 tubing female connector Long 13 400 25
MVANO Adult Nasal O2 tubing female connector Standard 6.5 200 25
MVANO100U Adult Nasal O2 tubing female connector Standard 6.5 200 100
MVANOL Adult Nasal O2 tubing female connector Long 13 400 25
MVANOL100U Adult Nasal O2 tubing female connector Long 13 400 100
MVPNO Pediatric Nasal O2 tubing female connector Standard 6.5 200 25
MVAN Adult Nasal No O2 delivery Standard 6.5 200 25
MVIN Neonatal Nasal No O2 delivery Standard 6.5 200 25
MVPN Pediatric Nasal No O2 delivery Standard 6.5 200 25
MVAB Bite block O2 male connector Standard 6.5 200 25
MVABO Bite block O2 tubing female connector Standard 6.5 200 25
MVABOL Bite block O2 tubing female connector Long 13 400 25
MVAB100U Bite block O2 male connector Standard 6.5 200 100
MVABO100U Bite block O2 tubing female connector Standard 6.5 200 100
MVABOL100U Bite block O2 tubing female connector Long 13 400 100
MVXL MRI filter line No O2 delivery Extra long 30 900 25

Microstream™ Advance filter lines for intubated patients — long-term use

Item number Size Description Configuration Length Length (ft) Length (cm) Units per box
MVAIH Adult/pediatric For use with ETT > 4.5 mm Standard 6.5 200 25
MVAIH100U Adult/pediatric For use with ETT > 4.5 mm Standard 6.5 200 100
MVAIHL Adult/pediatric For use with ETT > 4.5 mm Long 13 400 25
MVIIH Neonatal For use with ETT ≤ 4.5 mm Standard 6.5 200 25
MVIIHL Neonatal For use with ETT ≤ 4.5 mm Long 13 400 25
MVAIHH Adult/pediatric For use with ETT > 4.5 mm Standard 6.5 200 25
MVIIHH Neonatal For use with ETT ≤ 4.5 mm Standard 6.5 200 25

Microstream™ Advance filter lines for intubated patients — short-term use

Item number Size Description Configuration Length Length (ft) Length (cm) Units per box
MVAI Adult/pediatric For use with ETT > 4.5 mm Standard 6.5 200 25
MVAI100U Adult/pediatric For use with ETT > 4.5 mm Standard 6.5 200 100
MVAIL Adult/pediatric For use with ETT > 4.5 mm Long 13 400 25

The Microstream™ capnography monitoring system should not be used as the sole basis for diagnosis or therapy and is intended only as an adjunct in patient assessment.

† All technical information is sourced from the information for use (IFU) documents PT00160417, PT00160416, PT00156250, PT00156254, and PT00156409. Please reference the instructions for use (IFU) for a complete product details.

  1. Gozal D. Evaluation of EtCO2 readings between the Smart CapnoLine™ O2 and a direct post-pharyngeal catheter. Oridion Bench Testing. 2002.
  2. Based on internal report D005621, EtCO2 monitoring of nonintubated patients receiving oxygen and any form of sedative drugs (protocol, see objectives 1 and 2). 2020.
  3. Blonder Y, Mazor E, Jew K. Advanced capnography sampling lines may improve patient comfort and compliance. Med Devices (Auckl ). 2021;14:37–42.