No Image Available

Laparoscopic instruments

LigaSure™ Maryland jaw sealer-divider with nano-coating

<p>The LigaSure™ Maryland jaw laparoscopic sealer-divider vessel sealing device includes a nonstick nano-coating technology.</p>

Features

Nonstick, nano-coating

The LigaSure™ Maryland jaw device with nano-coating delivers:

  • Reduced eschar buildup1,2
  • Decreased instances of sticking†,2,3
  • Reduce jaw cleanings - and make cleaning easier‡,1,2

Multifunctional flexibility

With the LigaSure™ Maryland jaw device you get the benefits of:

  • A one-step vessel sealer4
  • A Maryland dissector for enhanced blunt dissection§,2,5
  • An atraumatic grasper to securely grasp tissue◊,2,5
  • Cold scissors to leave the critical decision to cut in your hands2,4,5

Multifunctional performance

The LigaSure™ Maryland jaw device delivers:

  • Improved tip visualization compared to straight jaws#,6
  • Easy skeletonization of vessels#,2,6
  • Improved access compared to straight jaws#,2,6

Specifications

Physical characteristics
General  Sterile, single use
Shaft rotation 350 degrees
Jaw design Curved
Jaw coating Nano-coating
Seal plate length (mm) 20.3
Cut length (mm) 18.5
Foot switching Yes
Generator compatibility Valleylab™ FT10 energy platform, Valleylab™ LS10 generator

Ordering information

Item number Description Shaft length (cm) Units per box
LF1923 LigaSure™ Maryland jaw sealer-divider with nano-coating 23  6
LF1937 LigaSure™ Maryland jaw sealer-divider with nano-coating 37  6
LF1944 LigaSure™ Maryland jaw sealer-divider with nano-coating 44  6

TM* Third-party brands are trademarks of their respective owners.

† Instances of tissue sticking to jaws measured over 110 seals per device.

‡ Cleaning effectiveness assessed after each of two cleaning cycles.

§ When compared to the surgeon’s primary device, 23 out of 32 surveyed agreed.

◊ 33 out of 33 surgeons surveyed agreed. 

¶ 31 out of 32 surgeons surveyed agreed.

# 30 out of 33 surgeons surveyed agreed.

∆ 31 out of 33 surgeons surveyed agreed.

  1. Based on internal test report RE00071599, LF19XX MJC, Marketing claims report conducted on porcine tissue. February 7 to February 22, 2017.
  2. Based on internal test report RE00140529 rev A, LigaSure™ Maryland device, nano-coated (LF19XX) tissue testing (memo). Mar. 5, 2018.
  3. Based on internal test report RE00073194, Tissue sticking comparison of the Ethicon G2™*, Voyant™* 5 mm Fusion, LigaSure™ LF1737, and LigaSure™ LF1937 devices conducted on porcine tissue using the Force Triad™ energy platform. January 18, 2017.
  4. Based on internal test report PT00076257, LigaSure™ Maryland jaw sealer-divider, nano-coated instructions for use. Medtronic, Boulder, CO; 2016.
  5. Based on internal test report R0035742, Maryland validation labs: independent surgeon feedback collected during porcine labs in Houston and Los Angeles. April 16 to 18 and April 30 to May 3, 2013.
  6. Based on internal test report RE00071598, Maryland validation labs: independent surgeon feedback collected during porcine labs in Houston and Los Angeles. April 16 to 18 and April 30 to May 3, 2013.