Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
UNDERSTAND
THE INDICATIONS
Learn the parameters of patient selection for Parkinson’s disease, epilepsy, essential tremor, dystonia, and OCD.
VIEW INDICATIONSDBS for Parkinson's
Patient website
Information for your patients on DBS therapy for Parkinson's disease, including patient stories.
View websiteMedtronic MR Conditional† DBS systems are backed by more than 14 years of MRI research and testing history.1
LEARN ABOUT MRIAccess the Medical Education Program for Health Care Professonals in the field of movement disorders and epilepsy.
Visit our Impact siteMedtronic data on file: Report; NDHF1443-128376 - DBS Expanded MRI Labeling RF Lead Heating Design Verification Test Report
Medtronic’s Activa™ PC+S device received CE Mark on January 17, 2013, but was not commercially distributed.
Medtronic DBS systems are MR Conditional and safe in the MR environment as long as certain conditions are met. If the conditions are not met, a significant risk is tissue lesions from component heating, especially at the lead electrodes, resulting in serious and permanent injury including coma, paralysis, or death. Refer to the MRI Guidelines for Medtronic Deep Brain Stimulation Systems at www.medtronic.com/mri or contact Medtronic at +44 (0) 1923 205101 for a complete list of conditions. Also review current MRI manufacturer labeling before conducting the MRI.
Brief Statement:
See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. If using an MRI SureScan® device, see the MRI SureScan® technical manual before performing an MRI. For further information, contact your local Medtronic representative and/or consult the Medtronic website at medtronic.eu.