Healthcare Professionals

ParaMount Mini GPS Balloon-expandable Peripheral and Biliary Stent 

Peripheral and Biliary Stenting

Overview

See your way to accurate stent deployment when you choose the ParaMount™ Mini GPS™ balloon-expandable peripheral stent system with its radiopaque markers that enhance visibility before, during and after stent placement. The system's low profile is designed for flexibility and easy navigation to target lesions in the renal anatomy and as a palliative treatment in the biliary tree.


Indications

Peripheral

The ParaMount Mini GPS balloon-expandable peripheral stent is indicated for use in occlusions, lesions at high risk for abrupt closure or threatened closure following percutaneous transluminal angioplasty (PTA) or lesions believed to be at high risk of stenosis following PTA in the renal arteries. Stenting is intended to improve and maintain artery luminal diameter.

Biliary

The ParaMount Mini GPS balloon-expandable peripheral stent is indicated for use as a palliative treatment of malignant neoplasms in the biliary tree.

All indications related to the PARAMOUNT MINI GPS BALLOON-EXPANDABLE PERIPHERAL AND BILIARY STENT are not approved globally, please refer to the complete Instructions for Use manual for the indication for Use approved in your geography.  


Product Details

High Visibility

  • GPS radiopaque tantalum markers are built into each end of the stent for enhanced procedural accuracy and visibility.
  • GPS markers identify proximal and distal edges as the stent is expanded.
  • GPS technology allows stent to remain visible under fluoroscopy to verify stent placement.
Location of GPS radiopaque markers on the end of a Paramount Mini GPS stent.

GPS Markers

Location of GPS radiopaque markers on the end of a ParaMount Mini GPS stent.

Low Profile System

  • Available on either an 0.014" and 0.018" guidewire compatible balloon catheter.
  • Compatible with a 6 F or 7 F guide catheter.
  • Designed for flexibility when navigating to a target lesion.

Strength and Flexibility

  • Unique cell geometry provides greater radial strength and support.

Precision

  • Medtronic's exclusive Micro-Grip™ technology keeps the stent properly centered prior to expansion.
  • Stent exhibits minimal shortening at recommended expansion diameters

Manuals and Technical Guides

Instructions for Use
Find this technical manual in the product labeling supplied with each device or by calling technical support for cardiovascular services: +1 763-526-7890.


Model Specifications

 

Reference Number

0.014 Guidewire 

Reference Number

0.018 Guidewire 

Expanded Stent Diameter 

(mm)

Expanded Stent Length 

(mm)

Balloon Length (mm)

Recomm. Guide Catheter / Sheath Size (F)

PMP4-5-14-80

PMP8-5-14-80

5.0

14

17

6/5

PMP4-5-18-80

PMP8-5-18-80

5.0

18

20

6/5

PMP4-5-21-80

PMP8-5-21-80

5.0

21

24

6/5

PMP4-6-14-80

PMP8-6-14-80

6.0

14

17

6*/5

PMP4-6-18-80

PMP8-6-18-80

6.0

18

20

6*/5

PMP4-6-21-80

PMP8-6-21-80

6.0

21

24

6*/5

PMP4-7-14-80

PMP8-7-14-80

7.0

14

17

7/6

PMP4-7-18-80

PMP8-7-18-80

7.0

18

20

7/6

PMP4-7-21-80

PMP8-7-21-80

7.0

21

24

7/6

Normalized Stent Compliance Values
ParaMount Mini GPS Diameter (mm) Inflation Pressure (atm)
9 10 11 12
5.0 4.96 5.04 5.12 5.20
6.0 5.78 5.88 5.98 6.08
7.0 6.87 6.98 7.10 7.22
  Diameter at nominal pressure      
  Diameter at RBP

6 F = 0.070” I.D.

 

See product catalog for complete, detailed product information.