MiniMed™ 770G System Insulin Pump Technology

Real- World Outcomes With SmartGuard™ Auto Mode Technology 

Learn more

Overview

The MiniMed™ 770G insulin pump system helps your patients focus more on their daily life

 Automation

Automatically adjusts insulin delivery every 5 minutes
To help your patients prevent highs and lows*

Increased Time in SmartGuard Auto Mode
Compared to MiniMed™ 670G1 system

Improved MiniMed™ 770G Customer Experience
Compared to MiniMed™ 670Gsystem

 Connectivity

Patients can automatically upload their insulin and CGM data directly from their smartphone for easier patient care

Patients get notified on their phone
If they’re going high or low

CareLink™ Connect App
Data can be shared with up to 5 Care Partners

 Support

Always by your side
Largest global support team in the industry with 24/7 service

My Insights
Providing insights & encouragement based on CareLink™ observations

1

Medtronic data on file: MiniMed ™ 770G and MiniMed™ 670G data uploaded voluntarily by 59,333 users in the US to CareLink™ Personal, from Nov 2020  to  8 Aug 2022

2

Medtronic data on file: NPS satisfaction scores FY22Q4 MiniMed™ 770G vs 670G users, 30th July 2022

Enabled for future software upgrades

 

Any customer using the MiniMedTM 770G system will get access to our next technology, when available, at no cost.

Our next innovation goal is to reduce fingersticks and bring you an advanced algorithm with auto-correction bolus for easier mealtimes. Get access to the future by filling out the form below and learning more about the MiniMedTM 770G system.


Learn more about our future innovations.

Real-world outcomes



87.5%

Time in
SmartGuardTM
Auto Mode1



156.2
mg/dL

Mean sensor
glucose1



7.0%

Mean Glucose
Management Indicator
(GMI)1

1

Medtronic data on file: MiniMed ™ 770G and MiniMed™ 670G data uploaded voluntarily by 59,333 users in the US to CareLink™ Personal, from Nov 2020 to 8 Aug 2022
Due to inherent analysis limitations, caution is advised when attempting to extrapolate these results to new patients. There could be significant differences.

SmartGuard™ Auto Mode

Impacts to Time in Range during the night1

Three graphs comparing the average nighttime time in range of patients.
1

Patients included in analysis must meet the following criteria: At least 10 days of sensor data after the SmartGuard™ initiation periods

2

Medtronic data on file: MiniMed™ 770G and MiniMed™ 670G data uploaded voluntarily by 11,231 users in the US to CareLink™ Personal with >10days of pre and post data from Nov 2020 to 8 Aug 2022. Due to inherent analysis limitations, caution is advised when attempting to extrapolate these results to new patients. There could be significant differences.

Minimed™ 770G System overview

To help keep your patients in safe range

Expand All

1. Insulin pump

2. Infusion set

3. Continuous glucose monitor (CGM)

4. Smartphone apps

The components of the MiniMed 770G insulin pump system shown on the body.

Automatic CareLink™ data uploads

Enabling meaningful patient conversations

Two images showing a physician and patient looking at CareLink data on a tablet.

TheMiniMed™ 770G system with Bluetooth® connectivity enables automatic CareLink™ uploads, helping support meaningful conversations with your patients, whether in-person or via telehealth.

No more last-minute pump uploads

Convenient

  • Your patients’ data can now be easily uploaded prior to their appointments.

Actionable

  • Providing access to insights for your patients’ therapy adjustments.

Available 24/7

  • Giving you and your patients the ability to view data whenever needed.

Smartphone connectivity enables new features

Helping your patients and their families live more and worry less. 

MiniMed™ Mobile app

Your patients can now use their smartphones to view their data. This means they can easily and discreetly track their glucose levels and get notified of highs and lows.

The MiniMed Mobile app
The MiniMed Mobile app

CareLink™ Connect app

Available for care partners, this app helps keep everyone in the loop. Up to five care partners can now follow a pump user and receive high and low notifications.

The CareLink Connect app.
The CareLink Connect app.
Expand All

Technical Specifications

Compatible Products

Request more information

Complete the form below and a representative will follow up with additional information.

This form is for Healthcare Professionals. If you are a patient looking for more information click here

* Indicates a required field.

Your information will be used and protected in accordance with our privacy statement.

*

Refers to SmartGuard™ Auto Mode. Some user interaction required. Induvial results may vary.

Based on real world evidence comparing 54,009 MiniMed™ 670G users vs. 59,333 MiniMed™ 770G users. Due to inherent analysis limitations, caution is advised when attempting to extrapolate these results to new patients. There could be significant differences. 

Software Upgrade Terms and Conditions

  • This program allows MiniMed™ 770G system users a software upgrade at no charge within one year from the date of this software approval. Software approval will be announced.
  • Software upgrade process is subject to change. The process may result in healthcare provider office visit and may result in out-of-pocket expenses such as co-pay, depending on insurance coverage. The process may require the completion of product related training.
  • This program includes the insulin pump software only. CGM products and consumables are not included in this offer.
  • Warranty dates do not reset. The replacement warranty date of an insulin pump upgraded with the software will remain the same as the replacement warranty date of the initial pump purchased. Your warranty date does not impact eligibility for a software update.
  • MiniMed™ pumps and software have certain labeling restrictions that may exclude certain populations, including age and type of diabetes. We recommend you consult your healthcare provider regarding your eligibility to receive the software upgrade based on the labeling of the upgrade, which may differ from the labeling of the MiniMed™ 770G pump.
  • Insurance coverage and plan design varies and may impact the ability to upgrade. Coverage is contingent upon your health insurance medical policy guidelines. Restrictions and medical necessity requirements may apply.
  • A valid prescription will be required for this software upgrade. All participants should consult their healthcare provider for all therapy related decisions.
  • Program terms and conditions are subject to change at any time and without notice. Other restrictions may apply.

Important Safety Information: MiniMedTM 770G System with SmartGuardTM Technology

The MiniMed™ 770G system is intended for continuous delivery of basal insulin (at user selectable rates) and administration of insulin boluses (in user selectable amounts) for the management of type 1 diabetes mellitus in persons two years of age and older requiring insulin as well as for the continuous monitoring and trending of glucose levels in the fluid under the skin. The MiniMed™ 770G system includes SmartGuard™ technology, which can be programmed to automatically adjust delivery of basal insulin based on continuous glucose monitoring (CGM) sensor glucose (SG) values and can suspend delivery of insulin when the SG value falls below or is predicted to fall below predefined threshold values.

The Medtronic MiniMed™ 770G system consists of the following devices: MiniMed™ 770G insulin pump, the Guardian™ Link (3) transmitter, the Guardian™ Sensor (3), one-press serter, the Accu-Chek® Guide Link blood glucose meter, and the Accu-Chek® Guide test strips. The system requires a prescription.

The Guardian™ Sensor (3) has not been evaluated and is not intended to be used directly for making therapy adjustments, but rather to provide an indication of when a fingerstick may be required. All therapy adjustments should be based on measurements obtained using a blood glucose meter and not on values provided by the Guardian™ Sensor (3).

All therapy adjustments should be based on measurements obtained using the Accu-Chek® Guide Link blood glucose meter and not on values provided by the Guardian™ Sensor (3). Always check the pump display to ensure the glucose result shown agrees with the glucose results shown on the Accu-Chek® Guide Link blood glucose meter. Do not calibrate your CGM device or calculate a bolus using a blood glucose meter result taken from an alternative site. It is not recommended to calibrate your CGM device when sensor or blood glucose values are changing rapidly, e.g., following a meal or physical exercise.

WARNING: Do not use the SmartGuard™ Auto Mode for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in SmartGuard™ Auto Mode.

WARNING: Do not use the MiniMed™ 770G system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMed™ 770G system.

Pump therapy is not recommended for people whose vision or hearing does not allow recognition of pump signals and alarms. Pump therapy is not recommended for people who are unwilling or unable to maintain contact with their healthcare professional. The safety of the MiniMed™ 770G system has not been studied in pregnant women. For complete details of the system, including product and important safety information such as indications, contraindications, warnings and precautions associated with system and its components, please consult http://www.medtronicdiabetes.com/important-safety-information#minimed-770g and the appropriate user guide at http://www.medtronicdiabetes.com/download-library

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Medtronic is under license.”