Overview

An advanced solution for thick tissue applications

The only reload designed specifically for use in extra-thick tissue applications, the Endo GIA™ black reload with Tri-Staple™ technology offers a 50% thicker tissue range compared with the Echelon Flex™* green reload.([FOOTNOTE=Indicated tissue thickness range: Endo GIA™ black reload (2.25 mm to 3.00 mm) vs. Echelon Flex™* green reload (2.0 mm).],[ANCHOR=],[LINK=]) It is ideal for thick, dense tissues commonly found in challenging bariatric and thoracic procedures.

On-Demand Webinar for Surgeons

Spotlight on Perfusion: New Technology and Data

Learn More 

Features

  • Thickest indicated tissue range on the market (2.25 mm–3.00 mm)1
  • Designed for extra thick, dense tissues commonly found in challenging bariatric procedures such as revisions and sleeve gastrectomies
  • Variable staple heights (4.0 mm, 4.5 mm, 5.0 mm) and stepped cartridge face

Order Information

Order Information
Order Code Description Cartridge Color Staple Size (inner to outer row) Quantity
EGIA45AXT Endo GIA™ 45 mm Articulating Extra Thick Reload
with Tri-Staple™ Technology
Black 4 mm, 4.5 mm, 5 mm 1 Each
EGIA60AXT Endo GIA™ 60 mm Articulating Extra Thick Reload
with Tri-Staple™ Technology
Black 4 mm, 4.5 mm, 5 mm 1 Each

Technology

Advanced technology for optimal interaction between stapler and tissue

No single stapler can address the wide range of tissue management issues surgeons face on a daily basis. That's why we have developed a portfolio of stapling solutions designed to meet specific needs and challenges. Each reload incorporates unique and proprietary features that deliver performance conventional staplers simply can’t match.

All of our stapling reloads incorporate our proprietary Tri-Staple™ technology. With its unique design elements like a stronger fixed anvil, stepped cartridge face and staggered staple heights, Tri-Staple™ technology delivers graduated compression that:

  • Reduces stress on tissue during clamping and compression([FOOTNOTE=When compared with Echelon Flex™* green reloads as part of a September 2, 2011 analysis comparing different stapler designs and their performance and impact on tissues under compression using two-dimensional finite element analysis (data on file).],[ANCHOR=],[LINK=])
  • Allows greater perfusion into the staple line([FOOTNOTE=Analysis of Staple Line Vascularity Using MicroCT between Covidien 60 mm AVM Tan reload and Ethicon 60 mm 2.5 mm White reload dated April 27, 2015. Covidien Engineering Report No: 2128 002 2.],[ANCHOR=],[LINK=])
  • Provides superior performance in variable tissue([FOOTNOTE=Based on internal test report #PCG-001, Tyvek pull-apart test comparing Echelon™* and Tri-Staple™ technology (data on file at Medtronic). March 2011.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-004, Undercrimp comparisons in increasing pads of foam between Echelon™* and Tri-Staple™ technology (data on file at Medtronic). January 2012.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-006, Staple Formation Comparison between Medtronic EGIA60AXT and Ethicon ECR60G in an Ex-Vivo Tissue Model (data on file at Medtronic). January 2012.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-018, 2D FEA of Linear Staplers (data on file at Medtronic). November 2012.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #PCG-019, Comparative Test of Medtronic Endo GIA™ Black Reloads with Tri-Staple™ Technology and Ethicon ECHELON FLEX™* Black Reloads (data on file at Medtronic). June 2014.],[ANCHOR=],[LINK=]),†

  • †Pre-clinical results may not correlate with clinical performance in humans.