Motility testing diagnostic systems

Endoflip™ 300 impedance planimetry system

<p>The Endoflip™ 300 impedance planimetry system is used to measure pressure and dimensions in the esophagus, pylorus, and anal sphincters.</p>

Features

See an illustration showing 1/2 of something.


Up to 50% of endoscopies for predominant esophageal reflux symptoms are negative.8

Illustration of a pie chart with 1/3 cut out


One in three patients referred with ongoing symptoms while using PPIs doesn’t have GERD.9

Illustration of pills with cross out symbol


PPI use has been associated with osteoporosis and other risks.10
 

You need an objective means of diagnosing GERD and motility disorders. 

There are many types of motility disorders, and pinpointing the underlying cause of the patient’s symptoms can be challenging.11

The Endoflip™ impedance planimetry system can provide information that can provide information to aid in therapeutic decision making.12

See a healthcare professional using the  Endoflip™ 300 system.

How does Flip™ technology work?

Endoflip™ technology uses high-resolution impedance planimetry to measure luminal geometry and pressure during volume-controlled distension. It helps you assess the mechanical properties of the esophageal wall and opening dynamics of the gastroesophageal junction in various esophageal diseases.​

See a closeup of the EndoFlip™ impedance planimetry system screen.

Ordering information

Item number Description Units per box
EF-301 Endoflip™ 300 pump system 1
EF-302 Endoflip™ 300 display system 1
EF-303 Endoflip™ 300 300 cart 1
EF-322N Endoflip™ measurement catheter 16 cm 1
EF-325N Endoflip™ measurement catheter 8 cm 1
ES-320 Esoflip™ dilation catheter 20 mm 5
ES-330 Esoflip™ dilation catheter 30 mm 5

Related links

Capsule Endoscopy System Tech Support Promo Box

Technical support

Get technical support for all endoscopy products.

Email us
Phone
: 1-800-448-3644, option 3

Similar products

  1. Endoflip™ 300 operator’s manual.
  2. Carlson DA, Gyawali CP, Kahrilas PJ, et al. Esophageal motility classification can be established at the time of endoscopy: a study evaluating real-time functional luminal imaging probe panometry. Gastrointest Endosc. 2019;90(6):915–923.
  3. Farina D, Carlson D. Functional luminal imaging probe (FLIP) as an adjunctive modality in evaluation of esophageal dysmotility. Foregut. 2021(1);286–295.
  4. Ilczyszyn A, Botha A. Feasibility of esophagogastric junction distensibility measurement during Nissen fundoplication. Dis Esophagus. 2014;27(7):637–644.
  5. Carlson, Dustin A. Evaluation of esophageal motility during endoscopy with the functional luminal imaging probe. Techniques in Gastrointestinal Endoscopy. 2018;20(3):107–113.
  6. Hirano I, Pandolfino JE, Boeckxstaens GE. Functional lumen imaging probe for the management of esophageal disorders: expert review from the clinical practice updates committee of the AGA institute. Clin Gastroenterol Hepatol. 2017;15(3):325–334.

  1. Su B, Dunst C, Gould J, et al. Experience-based expert consensus on the intra-operative usage of the Endoflip impedance planimetry system. Surg Endosc. 2021;35(6):2731–2742. doi:10.1007/s00464-020-07704-3.
  2. Muthusamy VR, Lightdale JR, Acosta RD, et al. The role of endoscopy in the management of GERD. Gastrointestinal Endoscopy. 2015;81(6):1305–1310. doi: 10.1016/j.gie.2015.02.021. 
  3. Herregods TV, Troelstra M, Weijenborg PW, et al. Patients with refractory reflux symptoms often do not have GERD. Neurogastroenterol Motil. 2015;27(9):1267–1273. 
  4. Vakil N. Prescribing proton pump inhibitors: Is it time to pause and rethink? Drugs. 2012;72(4):437–445. 
  5. Chaudhury A, Mashimo H. Oropharyngeal & esophageal motility disorders. Current Diagnosis & Treatment: Gastroenterology, Hepatology and Endoscopy. 2016;3:164.
  6. Ahuja NK, Agnihotri A, Lynch KL. Esophageal distensibility measurement: impact on clinical management and procedure length. Dis Esophagus. 2017;30(8):1–8.

These products are licenced with Health Canada as ENDOFLIP 300 PUMP SYSTEM, ENDOFLIP 300 DISPLAY SYSTEM and ENDOFLIP 300 CART on Health Canada licenced number 110272.