No Image Available

Intrasaccular devices

Artisse™ intrasaccular device

<p>Artisse™ is a flex-to-fit intrasaccular device that conforms to the shape of the aneurysm.<sup>1-4, 12</sup></p>

Features


Comprehensive Access portfolio

Artisse™ completes our comprehensive portfolio of neurovascular products and reflects our ongoing commitment to delivering meaningful innovation to advance stroke treatment.

Depending on the anatomy, this flex-to-fit intrasaccular device can be used alongside products such as the Rebar™ microcatheter 18 and Navien™ intracranial catheter to treat intracranial aneurysms. Explore the Neurovascular Product Catalog to learn more.

Product details

Comfortability

Flex-to-fit technology to take the shape of the aneurysm

Highly conformable, flexing to fit various aneurysm shapes, thanks to its unique flared design engineered from high-density platinum core nitinol DFT wires.1-4, 12

Reliability

Proven reliability you can trust

Proven reliability you can see and hear, with easy detachment and electrolytic detacher that gives instant confirmation.7,11

Control

Smooth, controlled deployment and ease of handling

Feels smooth, steady and predictable in your hands during deployment to help treat with confidence, precision and speed.7,14 

Safety

Atraumatic design at every step

From the smooth distal tip to the device deployment, Artisse is designed to reduce risk to, and stress on, the aneurysm walls.3,9


Artisse Detachment Device

Reliable detachment

Electrolytic detachment with audible and visual communications on detachment status.5

Ordering information

Artisse™ Intrasaccular Device

Item number Diameter (mm) Height (mm) Recommended Microcatherer (0.021")
ISF-045-030 4.5 3.0 Rebar-18
ISF-045-040 4.5 4.0 Rebar-18
ISF-050-030 5.0 3.0 Rebar-18
ISF-050-040 5.0 4.0 Rebar-18
ISF-055-030 5.5 3.0 Rebar-18
ISF-055-040 5.5 4.0 Rebar-18
ISF-055-050 5.5 5.0 Rebar-18
ISF-060-030 6.0 3.0 Rebar-18
ISF-060-040 6.0 4.0 Rebar-18
ISF-060-050 6.0 5.0 Rebar-18
ISF-065-030 6.5 3.0 Rebar-18
ISF-065-040 6.5 4.0 Rebar-18
ISF-065-050 6.5 5.0 Rebar-18
ISF-070-030 7.0 3.0 Rebar-18
ISF-070-040 7.0 4.0 Rebar-18
ISF-070-050 7.0 5.0 Rebar-18
ISF-075-040 7.5 4.0 Rebar-18
ISF-075-050 7.5 5.0 Rebar-18
ISF-080-040 8.0 4.0 Rebar-18
ISF-080-050 8.0 5.0 Rebar-18

Artisse™ Detachment Device

Item number Description
ISD-5-PK Artisse™ Detachment Device (5-pack)

*2-D sizing chart and 3D-Simulation

  1. Data on File D00360690 Artisse 2 Design Verification Implant Shape and Chronic Outward Force Report. 23-Nov-2020. 
  2. Data on File D00662662 Artisse 2 Rabbit Vessel Pouch Aneurysm GLP Animal Study Design Validation Report. Testing performed with 14 rabbits with a preexisting surgically created elastase induced aneurysm. 06-Nov-2023.
  3. Data on File M810805ADOC1 Artisse Implant Subassembly. 18-Sep-2023. 
  4. Data on File D00789514 Artisse 2 25% Compression Radial Force Design Verification Testing Report. 02- Sep-2022.
  5. Data on File. D00360690_A. D00662662.  D00363440_A
  6. HCP VOC FY22-23, in lab and gathered at conferences
  7. Data on File TR-NV12962 Artisse-021 System Design Validation Report. 19-Jul-2016. D00357033 Artisse 2 Intrasaccular Device Design Validation Report. 17- Nov-2020.
  8. Data on File: Artisse and Rebar-18 Microcatheter Design Verification Testing
  9. Data on File. D00314111_A_Appendix 7: Feasibility Testing and FEA Artisse-II DVT Justification Engineering Memo
  10. Data on File. DWGS31534- Pusher, Artisse. 13-Dec-22
  11. Data on File. TR-NV12721_A: Artisse-021 Detachment and Kink Resistance Test Report. Artisse Detachment Device IFU M993509ADOC2 Rev C
  12. Data on File. D01177929 Rev A Competitive testing report, intrasaccular device competitive evaluation. 
  13. Fiorella D, Molyneux A, Coon A, Szikora I, Demographic, procedural and 30-day safety results from the WEB Intra-saccular Therapy Study (WEB-IT).
  14. Data on file. Artisse Intrasaccular Device Conformability and Control Physician Survey
  15. NeuroNews Physician Interview on Clinical Perspectives on Artisse. Advertorial May 2024, Issue 54

This product is licenced with Health Canada as ARTISSE, on Health Canada licence number MDL# 113400.