Surgical heart valves
<p>The Contegra™ pulmonary valved conduit is an integrated valved conduit used in pulmonary replacement and reconstruction.</p>
See humanitarian use device section below.
None known.
Acceptable clinical performance has been established for the Contegra™ conduit in pediatric patients under the age of 10. Because of the possibility that complications of the device could become apparent only after extended use, a benefit-risk consideration of the long-term use of the Contegra™ conduit in pediatric patients over 10 years of age is particularly important.
General complications reported with valved conduits and biological tissue valves implanted in the heart include: endocarditis, hemolysis, hemorrhage (including anticoagulant-related hemorrhage), immunologic rejection, prosthesis calcification (intrinsic and extrinsic), prosthesis (conduit) dilatation, prosthesis (conduit) dissection, neointimal thickening, neointimal peeling/dehiscence, prosthesis regurgitation, prosthesis structural deterioration (perforation, tear, thickening, dissection, or myxomatous), prosthesis stenosis, prosthesis thrombosis, pulmonary hypertension, thromboembolism, residual or increasing transvalvular pressure gradient, obstruction of implant, pulmonary embolism, coronary artery compression.
For additional information, please refer to the instructions for use provided with the product.
Caution: Federal law (United States) restricts this device to sale by or on the order of a physician.
Authorized by federal law (United States) for use in patients under 18 years age for correction or reconstruction of the right ventricular outflow tract (RVOT) in the following congenital heart malformations: pulmonary stenosis, tetralogy of Fallot, truncus arteriosus, transposition with ventricular septal defect (VSD), pulmonary atresia. In addition, the Contegra™ pulmonary valved conduit is indicated for the replacement of previously implanted but dysfunctional pulmonary homografts or valved conduits. The effectiveness of this device for these uses has not been demonstrated.
For a listing of indications, precautions, and potential side effects, please refer to the instructions for use provided with the product or contact your local Medtronic representative.
Derived from a bovine jugular vein
Flexible for unique tailoring as only natural tissue can offer
Blood passes easily across a continuous tissue interface and natural sinus
Thin, extensible tissue especially suited for anastomosis
Easily customized to individual needs
Proximal length allowing for infundibular shaping without patching
Resilient wall retaining suture and supporting hemostatic suture line
No additional material necessary for proximal anastomosis
Readily available — no thawing or preclotting required
Download this brochure to learn more about the benefits of the Contegra™ valved conduit.
Reach out to CardioVascular Lifeline Technical Services with questions.
Phone: 877-526-7890
Follow us on Cardiac and Vascular LinkedIn.
The Harmony™ transcatheter pulmonary valve is designed to treat severe pulmonary regurgitation in patients with a native or surgically-repaired RVOT.
The Melody™ transcatheter pulmonary valve (TPV) uses Ensemble™ II transcatheter delivery system to treat right ventricular outflow tract (RVOT) dysfunction.